    							23 NAME
    Media Gap (Label Gap)
    Black Line
    Ribbon
    Presentation (Strip)
    Head-UpADJUSTMENT PROCEDURE (Message on Display)
    By volume B in media compartment.
     Sensitivity range (1st
    ).
    With Gap, 70% or more.
    With media (label), 35% or less
    SEE ABOVE NOTE BEFORE MAKING ADJUSTMENT
    By volume B in the media compartment.
    Sensitivity range (2nd
    )
    When black paper or color except black, 70% or more
    When black line, 35% or less
    By VR1 on TPB-2170
    Sensitivity range (Rib)
    With no ribbon, 70% or more
    With ribbon, 25% or less
    By VR2 on TPB-2170.
    Sensitivity range (Pre)
    When media (label), 75% or more
    When no media (label), 25% or less
    No volume for sensitivity adjustment. 
    						
    							25 10.0EXTERNAL CONNECTOR AND PIN ASSIGNMENTS
    Pin Assignments of RS232 Interface:
    Pin No.SignalPin No.Signal1N/C6DSR2RXD7RTS3TXD8N/C4DTR9N/C5GNDPin Assignments of Centronics Parallel Interface:
    Pin No.SignalPin No.SignalPin No.Signal1STROBE6DATA 511BUSY2DATA 17DATA 612PE3DATA 28DATA 713SEL4DATA 39DATA 814-17N/C5DATA 410AKNLG18-30GND 
    						
    							26 11.0VOLTAGE CHECK AND ADJUSTMENT
    Check TerminalSwitch Setting and
    Typ. VoltageUsage and Adjusted ByV1W           H:20.0 +/- 0.5
                   L: 18.0 +/- 0.5For Take-Up Motor
    By VR1 on Motor Control
    Board (TPB-2177)V2R            H: 20.0 +/- 0.5
                   L: 17.6 +/- 0.5For Ribbon Motor
    By VR2 on Motor Control
    Board (TPB-2177)NOTES:
    W switch for Take-Up Motor has to be set to ‘H’ side whenever Presentation Mode is
    selected.  In other modes, W switch should be set to ‘L’ side.
    R switch for Ribbon Motor is set to ‘L’ as usual. 
    						
    							27 12.0MAIN PCB BOARD
    Check
    TerminalTyp.
     VoltageUsage and
    Adjusted ByVcc
    + 5.0For logic circuit
    No adjustment volumeV-- 12.0For RS-232 interface
    No adjustment volumeV++ 12.5For RS-232 interface
    No adjustment volumeV
    TH+ 24.0For Thermal Head, DC motor and ribbon
    solenoid
    RV1 on switching power supply unit
    (PTR637-30)V
    SP+ 36.0For Stepping Motor
    RV1 on switching power supply unit
    (PTR637-30)NOTE:
    Check the voltage of V
    SP and V
    TH before you adjust the voltages by RV1.  RV1 adjusts
    both voltages simultaneously. 
    						
    							28 13.0TAKE-UP MOTOR CONNECTORS
                                         Connector                                                   Result
             Motor Side                                   Main Board
                 White                                             Blue                                    Clockwide
                   Red                                              Red
                 White                                            Red                                    Counter Clockwide