Page 11
11 fIGure 9. Figure 9 shows the typical attachment of the water piping to the water heater. The water heater is equipped with 1” NPT threaded nipple (75 gallon models) or 1.25” NPT threaded nipple (100 gallon models) water connections. note: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet connection. do not solder the cold water supply line directly to the cold water inlet. It will harm the dip tube and damage the...
Page 12
12 fIGure 10. fIllInG the water heater Never use this water heater unless it is completely full of water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” gas to the water heater. To fill the water heater with water: 1. Close water heater drain valve by turning handle to the right (clockwise). The drain valve is on the lower front of water heater. 2. Open the cold water supply...
Page 13
13 fIGure 12. There must be a minimum of 6” (153 mm) clearance between single wall vent pipe and any combustible material. Fill and seal any clearance between single wall vent pipe and combustible surfaces with mortar mix, cement, or other noncombustible substance. For other than single wall, follow vent pipe manufacturer’s clearance specifications. To insure a tight fit of the vent pipe in a brick chimney, seal around the vent pipe with mortar mix cement....
Page 14
14 Use pipe joint compound or teflon tape marked as being resistant to the action of petroleum [Propane (L.P.)] gases. The water heater and its gas connection must be leak tested before placing the water heater in operation. The water heater and its individual shut-off valve shall be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 pound per square inch (3.5 kPa). It shall be isolated from...
Page 16
16 for Your safetY read Before lIGhtInG Before lIGhtInG: entIre sYsteM Must Be fIlled wIth water and aIr purGed at faucets. warnInG: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of\ life. 1. STOP! Read the safety information above on this label. 2. Set the thermostat to the lowest setting by turning thermostat dial fully clockwise until it stops. 3. Push the gas control knob down...
Page 17
17 for Your InforMatIon start up condItIons draft hood operatIon Check draft hood operation by performing a worst case depressurization of the building. With all doors and windows closed, and with all air handling equipment and exhaust fans operating such as furnaces, clothes dryers, range hoods and bathroom fans, a match flame should still be drawn into the draft hood of the water heater with its burner firing. If the flame is not drawn toward the draft...
Page 18
18 Because of the suddenness and amount of water, condensation water may be diagnosed as a “tank leak”. After the water in the tank warms up (about 1-2 hours), the condition should disappear. Do not assume the water heater is leaking until there has been enough time for the water in the tank to warm up. An undersized water heater will cause more condensation. The water heater must be sized properly to meet the family’s demands for hot water including dishwashers,...
Page 19
19 You should check for sooting. Soot is not normal and will impair proper combustion. Soot build-up indicates a problem that requires correction before further use. Turn “OFF” gas to water heater and leave off until repairs are made, because failure to correct the cause of the sooting can result in a fire causing death, serious injury, or property damage. natural propane fIGure 17. Burner cleanInG If inspection of the burner shows that cleaning is required, turn the...
Page 20
20 In replacing the anode: 1. Turn off gas supply to the water heater. 2. Shut off the water supply and open a nearby hot water faucet to depressurize the water tank. 3. Drain approximately 5 gallons of water from tank. (Refer to “Draining and Flushing” for proper procedures). Close drain valve. 4. Remove old anode rod. 5. Use Tefl on® tape or approved pipe sealant on threads and install new anode rod. 6. Turn on water supply and open a nearby hot water faucet to...