Home > Acumen > Camera > Acumen Camera AiP53N User Manual

Acumen Camera AiP53N User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Acumen Camera AiP53N User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 53 Acumen manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 10 
    Chapter 3 Start Using H.264 FULL HD AiP camera 
    Network Features 
    After login H.264 FULL HD AiP camera as administrator, there are two main features—system operation and configuration.    Operation and configuration features are described as follows: 
    Chapter 3-1 AiP camera Operational HTML Page 
    H.264 FULL HD Series operational HTML page layout 
     
     
    1. Control panel—AiP camera control panel. 2. AI Universal ActiveX control—Display RTSP H.264 or JPEG network video. 3. Profile switching menu—Switching one profile to another 4. Setup menu—AiP camera setup menu  
    Chapter 3-2 AiP camera Main Page Controls AiP camera control panel contains ePTZ or ROI.    These features cannot co-exist together.    For ePTZ and ROI, they are described as below:  
    2. 
    3. 
    4. 
    1.  
    						
    							 11 
    Chapter 3-2-1 ePTZ 
    To operate AiP camera DSP’s ePTZ, please enable ePTZ feature on the main page.    A user can operate up, down, left, right, zoom in, zoom out, and presets on main page. 
     
    When ePTZ is off, AI Universal ActiveX control also provides ePTZ (electronically pan, tilt, and zoom) feature.   To perform ActiveX ePTZ feature, please use a computer mouse to drag on the ActiveX control.  
     
    AI Universal ActiveX control becomes eZoom mode. 
      
    						
    							 12 
    Please use computer mouse pointing to the sub-window of PIP view.    Dragging the sub-window can perform ePan and eTilt.    Using mouse scroll button can perform zoom in and out features.  Performing right-mouse click on the video can disable ePTZ feature.   Chapter 3-2-2 Region of Interest (ROI) For D1 and below resolution, ROI feature can apply to the main video stream.   Main video stream remains the biggest video resolution such as 1080P.    The sub-stream can be cropped and scaled based on the main video stream for saving bandwidth and storage. 
     
     
     
     
     
     
     
     
     
     Chapter 3-2-3 Control Panel 
    Control panel buttons are described as below: 
     Snapshot: Take a snapshot of the video. 
     Audio on: Set audio on (for audio model only). 
     Speak on: Speak to remote site (for audio model only). 
     Recording at PC 
     Activate alarm output (for alarm model only). 
     Auto Pan for presets at ePTZ or ROI mode 
     Home position for ePTZ or ROI mode 
    Presets Presets recall for ePTZ or ROI 
     Perform left, right, up, and down operations. 
     
    Main Video Stream: 1920 * 1080 
     
    Sub-stream:720 * 480  
    						
    							 13 
     Perform zoom in and out operations for ePTZ or ROI. 
    Speed  The PTZ speed of above operations. 
     
    Chapter 3-2-4 Two-way Audio 
     
    For two-way audio, please click on Microphone icon for speaking to the remote site.    To stop speaking to the remote site, please click on Microphone icon again. 
     
    To listen to the remote site, please click Speaker icon for listening to the remote site. To stop listening to the remote site, please click on Speaker icon again.    
     Chapter 3-2-5 Record in a Local PC 
    To record into a local PC, please first right-click on AI Universal ActiveX control.   It shows up in the setting dialog box.    A user can specify recording path and recording size.   Please make sure that the ePTZ or ROI feature is unchecked for displaying recording setting dialog box by right-mouse-click. 
                
    To playback the AVI video, simply click on Windows Media Player. 
    Chapter 3-3 Configuration 
    H.264 FULL HD AiP camera’s administrator can configure H.264 FULL HD AiP camera via standard HTML web page.    This chapter explains the detail of each configuration setting. 
    Note: Only IP camera models with audio can support this feature.  
    						
    							 14 
    Chapter 3-3-1 Server Settings 
    Server settings contain H.264 FULL HD AiP camera server’s system information such as MAC address, firmware version, users, system timer, and other system settings.    To change or to use these options, please follow the instructions at this section. 
     
    Firmware Version Firmware update allows a user to upgrade H.264 FULL HD AiP camera’s firmware remotely.    A user can use firmware version to verify if the device has the latest version. 
    Device Name The device name can be used by IPScan utility to identify the H.264 FULL HD AiP camera  To change the device name, enter the name for H.264 FULL HD AiP camera and click on Submit button. 
    Language Language setting can be changed dynamically. 
    OSD Name Camera OSD name 
    OSD Time Camera OSD time 
    ActiveX OSD Name Camera OSD name on only ActiveX  
    						
    							 15 
    Chapter 3-3-2 User Settings 
    There are ten user accounts allowed for the system.    Each account can be configured for its access rights.    To add/edit a user, please click on Add/Edit User button.    To access H.264 FULL HD AiP camera without authentication, set Bypass Logon radio button to ON.  
     
    To  change  account  name,  please  type  new  account  name  in  Account  edit  box.   To  change  new  password,  please  type  the  new  password  in  the  New  Password edit box.    Click on Submit button to update the user settings.    To delete a user, please click on “Remove User” button. 
     
    Administrator: Enable or disable setup mode for a user. Panel Control: Enable or disable Control Panel for a user. ePTZ: Enable or disable ePTZ feature for a user. Streaming: Enable or disable a streaming for a user.   
    						
    							 16 
    Chapter 3-3-3 Timer 
    H.264 FULL HD AiP camera allows a user to change system timer via standard HTML web page.    To change H.264 FULL HD AiP camera’s system timer, please enter the date and time in the edit boxes.    Click on Submit button to apply this operation. 
     
    Synchronize with NTP To synchronize Internet time system, check Auto Synchronize option to “Every Hour”.    H.264 FULL HD AiP camera synchronizes its system timer with a time server every hour.    
     
     
    Chapter 3-3-4 System Setting 
    Load Default feature allows to load manufacturing default.    There are certain critical settings such as IP addresses and video system which are not affected by this operation.    To reboot H.264 FULL HD AiP camera, click on Reboot System hyper link.   
     
      
      
    Note: Network Time Protocol feature requires Internet connection. 
    Note: In case of forgetting password, the device is required to send back to our company for a manufacturing default or read appendix for emergency default.  
    						
    							 17 
    To update firmware of H.264 FULL HD AiP camera, please click on Firmware   
    						
    							 18 
    Update hyper link.    Locate “flasham.bin” in your computer by clicking the Browse button.    Click Submit button to finish firmware upgrade.    To ensure the quality of transmission, please make sure that there is no user accessing H.264 FULL HD AiP camera during firmware upgrade. 
      
    Chapter 3-4 Network 
    H.264 FULL HD AiP camera provides Internet protocols including IP, DHCP, and DDNS.    A user can configure these Internet protocol settings.    To setup above, please read the following sections:    
    Chapter 3-4-1 General Settings 
    Network general settings are the basic settings connecting H.264 FULL HD AiP camera to the network.    The default IP Address of H.264 FULL HD AiP camera is 192.168.0.200.  A user can use this IP address to verify the network connection between a local PC and H.264 FULL HD AiP camera using Internet Browser.    For local area network configuration, please enter, at least, IP address, Subnet Mask, and Gateway IP.    Click Submit button to update these settings.  
    						
    							 19 
     
    For Internet access configuration, please contact your local ISP for global IP address.    Once the physical Internet connection gets installed, enter IP address (global), Subnet Mask, and Gateway IP from the ISP.    
      Default DNS IP Address—First Domain Name Server, the IP address of the domain name server  Second DNS IP Address—Second Domain Name Server, the IP address of the domain name server, a backup DNS server for default DNS  PPPoE Account—Account name of PPPoE service 
     PPPoE Password—Password of PPPoE service  
    Chapter 3-4-2 DHCP Setting 
    Router, gateway, or other software DHCP servers can dynamically assign an IP address to the H.264 FULL HD AiP camera.    There is no need to configure IP address, subnet mask, and gateway.    Since the DHCP may assign a different IP address to the H.264 FULL HD AiP camera after power off, a user can use IPScan utility to launch Internet browser for searching H.264 FULL HD AiP camera.      To enable DHCP, click on DHCP option and click on Submit button.  
     
     
    Note: Once the DHCP option gets enable, IP camera of the IP address assigned by DHCP server.   This feature allows only in LAN environment.  
    						
    All Acumen manuals Comments (0)

    Related Manuals for Acumen Camera AiP53N User Manual