Page 11

6.4 Cleaning the spark plug
This feature is obtained through a
ceramic ignition candle with a metal
electrode. Keep these components well clean to prevent difficult lighting and
check that the burner crown holes are
not obstructed.6.5  Periodic maintenance
Speak to your local Authorised Service Centre periodically to check the
conditions of the gas supply pipe and the pressure adjuster, if fitted.7.  TROUBLESHOOTINGWARNING!
Refer to Safety chapters.7.1  What to do if...ProblemPossible causeRemedyThere is...

Page 12

7.3 Labels supplied with the
accessories bag
Stick the adhesive labels as indicated
below:A. Stick it on Guarantee Card and send
this part (if applicable).
B. Stick it on Guarantee Card and keep
this part (if applicable).C. Stick it on instruction booklet.8.  INSTALLATIONWARNING!
Refer to Safety chapters.8.1  Before the installation
Before you install the hob, write down
the information bellow from the rating
plate. The rating plate is on the bottom
of the hob.
Model...

Page 13

However, if the room has a door whichopens directly to the outside no air vent
is required even if the volume is between 5 m³ and 11 m³.
If there are other fuel burning appliances in the same room, B.S. 5440 Part 2
Current Edition, should be consulted to determine the requisite air vent
requirements.
For appliances installed in the Republic
of Ireland please refer to the NSAI-
Domestic Gas Installation I.S. 813 Current
Editions Table Four.Location
The hob may be located in a kitchen, a
kitchen/diner or...

Page 14

5.Replace the rating plate (it is near the
gas supply pipe) with the one for the new type of gas supply. You can findthis plate in the package supplied
with the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure
adjuster on the gas supply pipe.8.5  Adjustment of minimum
level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum
position.
3. Remove the knob.
4. With a thin...

Page 15

A.Green and Yellow
B. 3 amp fuse
C. Brown
D. Cord clamp
E. Blue
The wires in the cord are coloured as
follows:
Green and yellow- EarthBlue- NeutralBrown- LiveWARNING!
A cut off plug inserted into a
13 amp socket is a serious
shock hazard. Ensure that
the cut off plug is disposed
of safely.8.7  Replacement of the
connection cableThe replacement of electric
cable must be carried out
exclusively by the service
force centre or by personnel
with similar competencies, in
accordance with the current...

Page 16

8.8 Assembly
1.
2.
3.
If a furniture unit is
installed at a distance of
400 mm above the hob,
there must be a
minimum safety distance
of 50 mm to the left or
right from the edge of
the hob.4.
5.
A) supplied seal
B) supplied brackets
6.
CAUTION!
Install the appliance only on
a worktop with flat surface.8.9  Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy accessin case a technical assistance
intervention is necessary.
www.aeg.com16 min. 55 mm
min. 650...

Page 17

Kitchen unit with door or drawerA.Removable panel
B. Space for connectionsKitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
9.  TECHNICAL DATA9.1  Hob dimensionsWidth590 mmDepth520 mm9.2 Bypass diametersBURNERØ BYPASS 1/100 mmRapid42Semi-rapid32Auxiliary289.3 Other technical data
TOTAL POWER:
Gas original:G20 (2H) 20 mbar = 7,7 kWGas replacement:G30 (3+) 28-30 mbar = 545 g/h
G31 (3+) 37 mbar...

Page 18

Gas connection:R 1/2" Appliance class:3 9.4 Gas burners for NATURAL GAS G20 20 mbarBURNERNORMAL POWER kWMINIMUM POWER
kWINJECTOR MARK
1/100 mmRapid2,90,75119Semi-rapid1,90,4596Auxiliary1,00,33709.5  Gas burners for LPG G30/G31 28-30/37 mbarBURNERNORMAL
POWER kWMINIMUM
POWER kWINJECTOR
MARK 1/100
mmNOMINAL GAS FLOW g/hG30 28-30
mbarG31 37 mbarRapid2,70,7586196193Semi-rapid1,90,4571138136Auxiliary1,00,3350737110.  ENERGY EFFICIENCY10.1  Product information according to EU 66/2014Model identification...

Page 19

• Center the pot on the burner.
• When you heat up water, use only the amount you need.
• If it is possible, always put the lids on the cookware.
• When the liquid starts to boil, turn down the flame to barely simmer the liquid. • If it is possible, use a pressure cooker. Refer to its user manual.11.  ENVIRONMENTAL CONCERNSRecycle the materials with the symbol .
Put the packaging in applicable
containers to recycle it. Help protect the
environment and human health and to recycle waste of electrical and...

Page 20

www.aeg.com/shop867321998-B-342016    
Start reading AEG Gas hob HG653430NB User Manual

Related Manuals for AEG Gas hob HG653430NB User Manual

All AEG manuals