    							CAUTION!
    Make sure that the gas
    supply pressure of the
    appliance obeys the
    recommended values.Rigid connection:
    Carry out connection by using metal rigid
    pipes (copper with mechanical end).
    8.5  Injectors replacement
    1.Remove the pan supports.
    2. Remove the caps and crowns of the
    burner.
    3. With a socket spanner 7 remove the
    injectors and replace them with the
    ones which are necessary for the type of gas you use (see table in
    "Technical Information" chapter).
    4. Assemble the parts, follow the same
    procedure backwards.
    5. Replace the rating plate (it is near the
    gas supply pipe) with the one for the new type of gas supply. You can find
    this plate in the package supplied
    with the appliance.
    If the supply gas pressure is changeable
    or different from the necessary pressure,
    you must fit an applicable pressure
    adjuster on the gas supply pipe.8.6  Adjustment of minimum
    level
    To adjust the minimum level of the burners:
    1. Light the burner.
    2. Turn the knob on the minimum
    position.
    3. Remove the knob.
    4. With a thin screwdriver, adjust the
    bypass screw position (A for external
    crown and B for internal crown).
    5. If you change:
    • from natural gas G20 20 mbar to liquid gas, fully tighten the bypass
    screw in.
    • from liquid gas to natural gas G20 20 mbar, undo the bypass screw
    approximately 1/4 of a turn for
    internal crown (B) and
    approximately 1/3 of a turn for
    external crown (A).
    WARNING!
    Make sure the flame does
    not go out when you quickly
    turn the knob from the
    maximum position to the
    minimum position.8.7  Electrical connection
    • Do not pull the mains cable to
    disconnect the appliance. Always pull
    the mains plug (if applicable).
    • The appliance must not be connected with an extension cable, an adapter or
    a multiple socket. There is a risk of fire.
    • Do not let the power cable to heat up
    to a temperature of more than 90° C.The cable should be guided by means
    ENGLISH21   A B   
    						
    							of clamps fixed to the side of the
    cabinet, in order to avoid any contact with the equipment beneath thecooktop.Electrical Requirements
    Permanent electrical installation must
    agree with the latest I.E.E. Regulations and local Electricity Board regulations.
    For your own safety the installation must
    be done by a qualified electrician (e.g.
    your local Electricity Board, or a
    contractor who is on the roll of the
    National Inspection Council for Electrical
    Installation Contracting [NICEIC]).
    The manufacturer refuses
    to be held responsible, if
    these safety measures are
    not abided by.Supply connections
    This hob has to be connected to 230 — 240 V ( 50 Hz) electricity supply.
    The hob has a terminal block which is
    marked as follows:
    • L or  1 - live terminal
    • N or  4 - neutral terminal
    •
     or  E or  5 - earth terminal
    Before carrying out the connection,
    make sure:
    1. The limiter valve and the electrical
    system can take the appliance load
    (see the rating plate)
    2. The supply system is equipped with
    an efficient earth connection in
    compliance with the current
    standards and regulations
    3. The outlet or omnipolar switch used
    for connection is easily accessible
    with the appliance installed.
    You must purchase and install the power
    cable. Use only a connection cable of type H05V2V2-F T90 or its equivalent.
    Make sure that the cable section is
    applicable to the voltage load and the
    working temperature.
    The wires in the cord are coloured as
    follows:
    Green and yellow- EarthBlue- NeutralBrown- LiveWARNING!
    A cut off plug inserted into a
    13 amp socket is a serious
    shock hazard. Ensure that
    the cut off plug is disposed
    of safely.8.8  Replacement of the
    connection cableThe replacement of electric
    cable must be carried out
    exclusively by the service
    force centre or by personnel
    with similar competencies, in
    accordance with the current
    regulations.Make sure that the cable
    section is applicable to the
    voltage load and the
    working temperature. The
    yellow/green earth wire (B)
    must be approximately 2 cm
    longer than the live and
    neutral wire (A).
    1. Connect the green and yellow (earth)
    wire to the terminal which is marked
    with the number 5, or the letter 'E', or
    the earth symbol 
    , or coloured
    green and yellow.
    2. Connect the blue (neutral) wire to the
    terminal which is marked with the
    number 4, or the letter 'N', or
    coloured blue.
    3. Connect the brown (live) wire to the
    terminal which is marked with the
    number 1, or the letter 'L'. It must
    always be connected to the network
    www.aeg.com22     A B   
    						
    							phase. There must be no cut or stray
    strands of wire present. The cord
    clamp must be correctly attached to
    the outer sheath.8.9  Attaching the seal
    1.Clean the worktop around the cut
    out area.
    2. Attach the supplied seal stripe to the
    lower edge of the hob along the
    outer edge of the glass ceramic. Do
    not extend it. Make sure that the
    ends of the seal stripe are located in the middle of one side of the hob.
    3. Add some mm when you cut the seal
    stripe to the length.
    4. Push the two ends of seal stripe
    together.8.10  AssemblyENGLISH23min. 450mm
    min.650mm
    min. 2mm  < 20 mm
    min. 2 mm
    A
    B
     A 12 mm28 mm 38 mm  B 57 mm41 mm31 mm
    min  30 mmmin. 500 mm > 20 mm
    min. 2 mm
    A
    B
     A 12 mm28 mm 38 mm  B 57 mm41 mm31 mm
    min. 500 mm  
    						
    							CAUTION!
    Install the appliance only on
    a worktop with a flat surface.8.11  Possibilities for insertionKitchen unit with door
    The panel installed below the hob must
    be easy to remove and let an easy access
    in case a technical assistance
    intervention is necessary.
    A) Removable panel
    B) Space for connections
    Kitchen unit with oven
    The electrical connection of the hob and
    the oven must be installed separately for
    www.aeg.com24R 5 mm
    min. 55 mm
    490  
    mm830  
    mm
    600 mm min. 38 mm min. 2 mm min. 12 mm min.  2 mm   min. 40 mm  (+2 mm)
    min. 30 mmmin. 60 mm
    b a   
    						
    							safety reasons and to let easy remove
    oven from the unit.If you install the hob
    asymmetrically rightward the
    minimum distance between
    left edge of the hob and left
    support must be 72 mm.9.  TECHNICAL INFORMATION9.1  Hob dimensionsWidth880 mmDepth520 mm9.2 Cooking zones specificationCooking zoneNominal power
    (maximum heat
    setting) [W]Power function
    [W]Power function
    maximum dura-
    tion [min]Cookware diam-
    eter [mm]Left front220036005180 - 210Left rear140025004125 - 145Right front140025004125 - 145Right rear1800280010145 - 180The power of the cooking zones can be different in some small range from the
    data in the table. It changes with the
    material and dimensions of the
    cookware.For optimal cooking results use
    cookware not larger than the diameter in
    the table.9.3  Bypass diametersBURNERØ BYPASS 1/100 mmDual (internal crown)29Dual (external crown)579.4 Other technical data
    TOTAL POWER:
    Gas original:G20 (2H) 20 mbar = 5 kWGas replacement:G30 (3+) 28-30 mbar = 334 g/h
    G31 (3+) 37 mbar = 329 g/hElectric zones:6,8 kWENGLISH25 min.  72 mm  
    						
    							Electric supply:230 V ~ 50 HzAppliance category:II2H3+ Gas connection:R 1/2" Appliance class:3 9.5 Gas burners for NATURAL GAS G20 20 mbarBURNERNORMAL POWER kWMINIMUM POWER
    kWINJECTOR MARK
    1/100 mmDual5,01,4270 / 115Dual (internal
    crown)0,80,33709.6  Gas burners for LPG G30/G31 28-30/37 mbarBURNERNORMAL
    POWER kWMINIMUM
    POWER kWINJECTOR
    MARK 1/100
    mmNOMINAL GAS FLOW g/hG30 28-30
    mbarG31 37 mbarDual4,61,4246 / 72334328Dual (inter-
    nal crown)0,80,3346585710.  ENVIRONMENTAL CONCERNSRecycle the materials with the symbol .
    Put the packaging in applicable
    containers to recycle it. Help protect the
    environment and human health and to recycle waste of electrical and electronic
    appliances. Do not dispose appliances
    marked with the symbol 
     with the
    household waste. Return the product to
    your local recycling facility or contact
    your municipal office.
    *