Home > AEM > Infinity Plug & Play Harnesses > AEM Honda 20002005 S2000 303508 User Manual

AEM Honda 20002005 S2000 303508 User Manual

Here you can view all the pages of manual AEM Honda 20002005 S2000 303508 User Manual. The AEM manuals for Infinity Plug & Play Harnesses are available online for free. You can easily download all the documents as PDF.

Page 1

P/N  3 0-3 508
2 000–2005 H onda S 2000
I n fin it y -6  a n d In fin it y -8 h * 
P lu g &  P la y A dap te r H arn ess
AEM  P erfo rm ance E le ctr o nic s
A EM  P erfo rm ance E le ctr o nic s, 2 205 1 26th  S tr e et U nit  A , H aw th orn e, C A 9 0250
P hone: ( 3 10) 4 84-2 322  F a x: ( 3 10) 4 84-0 152
h ttp ://w ww.a em ele ctr o nic s.c om
I n str u ctio n P art N um ber: 1 0-3 508
D ocum ent B uild  1 /6 /2 015
I
n str u ctio n
M an ual
STO P!
 T HIS  P RO DUC T H AS L E G AL R ESTRIC TIO NS....

Page 2

2
© 2 015 A EM  P erfo rm ance E le ctr o nic s
P
/N  3 0-3 508
OVE R VIE W
T he 3 0-3 508 A EM  In fin it y  A dapte r K it  is  d esig ned fo r th e 2 000–2 005 H onda S 2000. T hese m odels  in clu de
a ll  2 .0 L (A P1) e ngin es a s w ell  a s th e e arly  2 .2 L (A P2) e ngin es w it h  a  c able  d riv e n th ro ttle  b ody. T his  is  a
t ru e s ta ndalo ne s yste m  th at e lim in ate s th e u se o f  th e fa cto ry  E CU. T he u se o f  th is  a dapte r m akes th e k it
“ p lu g a nd p la y” s...

Page 3

2000–2005 H onda S 2000
3
© 2 015 A EM  P erfo rm ance E le ctr o nic s
*IM PO RTA NT IN FIN IT Y-8 H  IN FO RM ATIO N
T he p rim ary  d iffe re nce b etw een th e 3 0-7 106 In fin ity -6  a nd 3 0-7 108 In fin ity -8 h  is  th at th e 8 h la cks P eak
&  H old  in je cto r d riv e rs  to  ru n lo w  im pedance fu el  in je cto rs . H ig h im pedance (s atu ra te d, h ig h-z ) fu el
i n je cto rs  m ust b e u sed w it h  th e In fin it y -8 h.
  
T he In fin it y -6  a nd In fin it y -8 h s hare  a  c om...

Page 4

4
© 2 015 A EM  P erfo rm ance E le ctr o nic s
P
/N  3 0-3 508
IN FIN IT Y A DAPTE R  H A RNESS
I n clu ded w it h  th e 2 000–2 005 H onda S 2000 k it  is  a n a dapte r h arn ess. T his  is  u sed to  m ake th e
c onnectio n b etw een th e A EM  In fin it y  E M S a nd th e H onda w ir in g h arn ess p lu g a nd p la y. T his  is  d epic te d
b elo w  w it h  th e 8 0-p in  c onnecto r a nd th e H onda h eader. T here  a re  a ls o a  fe w  o th er in te gra te d c onnecto rs
w it h in  th is  h arn...

Page 5

2000–2005 H onda S 2000
5
© 2 015 A EM  P erfo rm ance E le ctr o nic s
DASHB O ARD
T he A EM  In fin it y  E M S fo r th e 2 000–2 005 H onda S 2000 d riv e s th e T achom ete r, C oola nt T em pera tu re
G auge, a nd th e C EL (C heck E ngin e L ig ht). S how n b elo w  a re  th e A P1 a nd A P2 g auge c lu ste rs .
R ath er th an O BD2 d ia gnostic s, th e C EL lig ht is  n ow  d edic ate d to  th e A EM  “M IL O utp ut” fe atu re . T he
A EM  M IL O utp ut a ctiv a te s if  a ny 1  o f  th e fo llo w...

Page 6

6
© 2 015 A EM  P erfo rm ance E le ctr o nic s
P
/N  3 0-3 508
IN FIN IT Y E M S IN STA LLA TIO N
Ste p  1
F ir s t, m ake s ure  th e H onda C D P la yer
a ctiv a tio n c ode is  re cord ed a nd a ls o ta ke
n ote  o f  th e ra dio  p re sets . N ext, o pen th e
h ood a nd d is connect th e b atte ry . R em em ber
t o  s et th e c lo ck w hen re connectin g th e
b atte ry . 
T he s to ck E CU is  lo cate d o n th e le ft -s id e
k ic k p anel,  a s s how n. P op o ff  a nd re m ove  th e
d oor s ill...

Page 7

2000–2005 H onda S 2000
7
© 2 015 A EM  P erfo rm ance E le ctr o nic s
Ste p  3
A tta ch o ne s id e o f  th e V elc ro  to  th e
b ack o f  th e E M S a nd th e o th er to  th e
c hassis , a s s how n. L oosely  s cre w  th e
O EM  E CU b olt  in to  th e s pare  b oss,
s how n in  re d.
A tta ch th e A EM  8 0-p in  c onnecto r to  th e
E M S. S ecure  th e In fin it y  c onnecto r b y
s lid in g th e re d lo ckin g ta b. 
S lid e th e E M S a ll  th e w ay u p u ntil  th e
a dapte r h arn ess c onto...

Page 8

8
© 2 015 A EM  P erfo rm ance E le ctr o nic s
P
/N  3 0-3 508
Ste p  5
If  a  w id eband U EG O s ensor w as
p urc hased, p ut th e c ar o n a  v e hic le  lift
( o r ja ck s ta nds).
W eld  in  a  b ung o r u se a n e xis tin g O 2
s ensor b ung th at is  p re  c ata ly tic
c onve rte r fo r o ptim al  a ccura cy.
U se a  7 /8 ” w re nch to  in sta ll  th e
w id eband U EG O s ensor (O EM  lo catio n
s how n). 
T he U EG O e xte nsio n h arn ess (s old
s epara te ly ) s hould  b e ro ute d a w ay fr o...

Page 9

2000–2005 H onda S 2000
9
© 2 015 A EM  P erfo rm ance E le ctr o nic s
PIN O UTS
In fin it y  P in out
Dedic ate d
Dedic ate d a nd n ot r e config ura ble
Assig ned
Assig ned b ut r e config ura ble
Ava ila ble
Ava ila ble  f o r u ser s etu p 
Not A pplic able
Not u sed in  t h is  c onfig ura tio n
Requir e d
Requir e d f o r p ro per f u nctio n
In fin ity
P in
In fin ity
A ssig nm en t
Honda P in
Honda D escrip tio n
In fin ity  H ard w are
S pecific atio n
Note s
1 LS  4
A17
A/C  C lu tc h R ela...

Page 10

10
© 2 015 A EM  P erfo rm ance E le ctr o nic s
P
/N  3 0-3 508
In fin ity
P in
In fin ity
A ssig nm en t
Honda P in
Honda D escrip tio n
In fin ity  H ard w are
S pecific atio n
Note s
12
Coil  3
C13
Ig nit io n C oil  P uls e
N o. 3
25 m A m ax s ourc e c urre nt
0–5V  f a llin g e dge f ir e . D o N OT c onnect
d ir e ctly  to  c oil  p rim ary . M ust u se a n ig nit o r o r
C DI th at a ccepts  a  f a llin g e dge f ir e  s ig nal.
13
Coil  2
C12
Ig nit io n C oil  P uls e
N o. 2
25 m A m ax s ourc...
Start reading AEM Honda 20002005 S2000 303508 User Manual

Related Manuals for AEM Honda 20002005 S2000 303508 User Manual

All AEM manuals