    1 | GT-OP2 / GT-OP3 Installation Instructions
    INSTALLATION & WIRING:
    The GT-OP2 and GT-OP3 Postal Lock Panels are for use with a GT Series Multi-Tenant Entry Security intercom system 
    and allow a postal lock device to be mounted alongside the entry panel. The lock device is available from the post office 
    and mounts behind the panel, accessible via the keyhole opening. The timer relay can be adjusted to provide a contact 
    closure from 5 to 20 seconds. NOTE:The GT-OP3 has an available position for an additional module. This opening can 
    be filled by any type of module, but must be purchased separately. 
    GT-OP3
    IMPORTANT: The GT-OP3 has an 
    available position for an additional 
    module. This opening can be filled 
    by any type of module, but must 
    be purchased separately.  Opening for 
    Postal Lock
    Blank Panel 
    (door release 
    circuitry inside)
    Open 
    module 
    position
    BLU
    YEL
    ORG
    RED
    BLK GT-OP2
    +
    - PS-2420UL
    AC 
    Power Electric 
    Strike
    NOTE: If using a magnetic lock, 
    connect to BLU & YEL wires.
    See color code definitions on Pg. 2.1114
    GT-OP2
    1. Install alongside a GT Entrance Panel. 
    2. When using GT-OP3, install an additional module in the open position at the top of the unit. 
    3. Secure wire connections as shown on wiring diagram.
    4. Cut the unused contact wire so the bare wires are not exposed.
    5. When mounting with a rain hood (GT-nH) or surface box with hood (GT-nHB), you must grind out the 
    bottom lip of hood / box for the lock to fit.Please contact Technical Support if further clarification is needed.
    6. Refer to standard GT Series Installation Manual for complete system information. 
    						
    							Aiphone Corporation
    1700 130thAve NE Bellevue, WA 98005
    Ph: (800) 692-9200   Fax: (425) 455-0071
    [email protected] 2 | GT-OP2 / GT-OP3 Installation Instructions
    SPECIFICATIONS:
    Power Source: 24V DC, powered by the PS-2420UL Power Supply
    Mounting: Semi-flush or surface mount (mounting box sold separately)
    Terminations: Color-coded pre-wired pigtails
    Relay Input: 24V DC, Red, Black wires, 22AWG
    Relay Output:  Blue (COM), Orange (N/O), Yellow (N/C) wires
    N/O Output rating: 5A at 30V DC
    10A at 125V AC
    3A at 250V AC
    N/C Ouptut rating:  3A at 30V DC or 125V AC
    Switch Output: Green (COM), White (N/C); Switch rated to 30V AC/DC, 1 amp
    Wiring: 2 conductors from 24V DC power supply to GT-OP panel
    2 conductors from GT-OP panel to strike, with power for strike wired in series
    Dimensions (HxWxD):  GT-OP2:  8-7/8 x 5-5/16 x 2
    GT-OP3: 12-5/8 x 5-5/16 x 2
    WIRING DIAGRAM:
    GT-OP2 Rear View
    Testing the unit without the postal lock:
    Tape or hold switch closed and apply power to the unit on Red / Black 
    leads. Release switch and timer circuit will activate. Confirm relay 
    activation with a multi-meter at the Blue / Yellow / Orange leads.
    TO 24V DC (+) RELAY COMMON CONTACT RELAY NORMALLY CLOSED CONTACTTO 24V DC (-) RELAY NORMALLY OPEN CONTACT SWITCH (NORMALLY CLOSED)SWITCH (COMMON)
    Timer control for door 
    release (5 to 20 seconds)
    Switch, activated by
    postal lock device
    (When lock is engaged, the switch 
    releases and starts timer)
    Lock device from Post 
    Office installed here
    Opening for postal 
    lock keyhole
    Lock device 
    mounting studs
    PC Board can be adjusted up 
    or down as needed to ensure 
    proper contact from the postal 
    lock to the switch
    REDBLUE YELLOWBLACK ORANGEWHITE* GREEN*
    * The green and white wires bypass 
    the timer circuit and go directly to the 
    switch. Use this connection when 
    going to a 3
    rdparty timer or when the 
    timer circuit is not needed. The 
    orange, black, yellow, blue, and red 
    wires would not be used if you 
    connect to the green / white bypass.
    IMPORTANT: If the Green and White wires are not used, cut wires to avoid a possible malfunction. 
    						