Home > Aiphone > Telephone > Aiphone GTTLI Instructions User Manual

Aiphone GTTLI Instructions User Manual

Here you can view all the pages of manual Aiphone GTTLI Instructions User Manual. The Aiphone manuals for Telephone are available online for free. You can easily download all the documents as PDF.

Page 11

11  
SET UP - Advanced Programming (continued)
Default Values
Tones
ON signal ringing
OFF signal ringing
ON signal busy
OFF signal busy
ON signal EOC
OFF signal EOCValue +/- Limits
1s +/- 200ms
3s +/- 200ms
200ms +/- 50ms
400ms +/- 50ms
500ms-200ms+50ms
500ms-200ms+50msMin & Max
800/1200
2800/3200
150/250
350/450
300/550
300/550 Values to Prog
080/120
280/320
015/025
035/045
030/055
030/055Default Values
135/165
315/385
045/055
045/055
045/055
045/055
Disconnect After Silence or Continuous Signal
Set	the...

Page 12

12 | GT-TLI Installation / Operation Instructions
SET UP - Advanced Programming (continued)
Audible Level of Voice Messages
Adjust	the	volume	level	of	audible	messages	played	at	the	GT	entrance	panel.
•	 Enter program access code   
⃰
2000#	-	“The	code	entered	is	correct”	will	be	played
•	 Enter 18 -	1	long	beep	will	be	played
•	 Enter n	(n	=	level,	0	max	level	-	7	min	level)	-	“The	code	entered	is	correct”	will	be	played
Voice	Messages
Message	#1:	 “Please	wait,	your	call	is	in	progress.”
Message	#2:...

Page 13

13 
SET UP - Quick Reference Programming Chart
			Password	 Code	 Function	 	 	 	 Parameters	 	 	 	 Default	Value
     
⃰
2000#	 18	 Audio	level	for	voice	message	 	 Max	0,	Min	7	 	 	 	 4
	 	 25	 DTMF	code	for	GT 	panel	relay	 	 2	digits	 	 	 	 	 10
	 	 29	 Restore	default	parameters	 	 Factory	default	 	 	 	 -
	 	 30	 DTMF	code	for	GT-TLI	dry	contact	 2	digits	 	 	 	 	 20	
	 	 32	 Duration	of	GT-TLI	dry	contact	 	 01	-	10	(1-10	seconds)	 	 	 05
	 	 35	 End	communication	when	activating	 0	=...

Page 14

14 | GT-TLI Installation / Operation Instructions
Locally Connected Telephone (i.e. cordless or corded telephone in apartment)
Receiving a call from the door:
•	Telephone rings
•	 “Call	from	door	panel”	message	is	played
•	 Communication can begin after message is played
•	 To	release	door	(buzz-in),	enter	2	digit	code	(default	is	10)
•	 System	will	disconnect	after	1	minute
Receiving	a	call	from	door	while	currently	on	phone:
•	 “Call	from	door	panel”	message	is	played
	 Option	1:	Do	nothing,	door...

Page 15

15	
15	
OPERATION - Mode Selection
Mode OFF
When	the	3	position	switch	(LOCAL	PROG/ON/OFF)	is	in	OFF	position,	GT 	panel	call	will	not	ring	the	locally	connected	
telephone or the remote telephone.
Mode ON Without Transfer
When	the	3	position	switch	(LOCAL 	PROG/ON/OFF)	is	in	ON	position	and	the	transfer	feature	is	not	turned	on,																		
the	GT 	panel	call	will	ring	the	locally	connected	telephone.
Mode ON With Transfer
When	the	3	position	switch	(LOCAL 	PROG/ON/OFF)	is	in	ON	position	and	the...

Page 16

PARAMETERS OF INSTALLATION
Programming	 	 	 	 	 Default	Value	 	 	 Installation
Ring	duration	of	the	internal	telephone	set	 45	seconds	 	 	 ___________________________
Remote	call	telephone	number	 	 	 460	 	 	 	 ___________________________
DTMF	code	for	operating			 	 10	 	 	 	 ___________________________
GT 	Panel’s	dry	contact
DTMF	code	for	operating	GT-TLI’s	 	 20	 	 	 	 ___________________________	
secondary dry contact
Operating	time	of	GT-TLI’s			 	 	 5	seconds	 	 	 ___________________________...

Page 17

17 
BASIC PROGRAMMING STEP FROM REMOTE TELEPHONE
Dial	the	phone	of	the	GT-TLI:	_____________	,	call	from	door	panel	will	be	played
Entering Remote Call Number
Enter 
 
⃰
2001#	-	“The	code	entered	is	correct”	will	be	played
Enter 21,	1	long	beep	will	be	played
Enter	telephone	number	____________	,	“The	code	entered	is	correct”	will	be	played
Enter 00	to	exit	-	3	short	beeps	will	be	played
Adjust Ring Duration of Local Telephone
Enter 
 
⃰
2001# 	-	“The	code	entered	is	correct”	will	be	played
Enter 20,	1...

Page 18

18 | GT-TLI Installation / Operation Instructions
SPECIFICATIONS
Dimensions	 	 9-7/16”	x	7-1/16”	x	2-1/16”,	240mm	x	180mm	x	53mm
Weight	 	 	 6.35	oz,	0.18	kg
Temperature	 	 32°F	-	140°F,	0°C	-	40°C	
Connections	 	 Standard	single	line	PBX	jack	master	socket	within	50	meters	or
	 	 	 PABX	extension	of	the	internal	telecommunication	network	of	a	company.
Power	required	 	 12V-24V	AC/DC	-	0.5A
Consumption	 	 12V	 AC/DC	 	 	 	 24V	 AC/DC
	 	 	 Standby:	95mA 			 	 	 Standby:	45mA
Standards	 	 EN60950...

Page 19

WARRANTY
Aiphone	warrants	its	products	to	be	free	from	defects	of	material	and	workmanship	under	normal	
use	and	service	for	a	period	of	two	years	after	delivery	to	the	ultimate	user.	Aiphone	will	repair	free	
of	charge	or	replace	at	no	charge	should	the	product	become	defective	upon	which	examination	
shall	disclose	to	be	defective	and	under	warranty.	 Aiphone	reserves	unto	itself	the	sole	right	to	make	
the	final	decision	whether	there	is	a	defect	in	materials	and/or	workmanship;	and	whether	or	not	the...

Page 20

Aiphone Corporation
1700	130th	Ave.	NE		Bellevue,	WA 	98005Ph:	(800)	692-0200	Fax:	(425)	455-0071
www.aiphone.com			[email protected] 