    For complete AX system information, please refer to the installation manual provided
    on the CD packaged with the CEU, or access from our web site at www.aiphone.com.
    - INSTRUCTIONS -
    The IE-SS/A and IE-SSR are vandal proof and weather resistant sub stations designed for use with the systems listed 
    above.  Theyre constructed with 12 gauge stainless steel, and the IE-SSR features a red mushroom call button. The 
    units either flush mount into a 2-gang box, or surface mount with the SBX-2G. Each unit includes tamper proof screws 
    and a tool for installation.
    Vandal Resistant Sub Stations for AX, IE, TD-H, TC-M Systems
    WIRING DIAGRAM (AX Series):
    MOUNTING:
    IE-SS/A
    (or IE-SSR)
    TORX
    screws
    2-GANG BOX
    INSTALLATION:
    1. For flush mounting, install sub station in standard 2-gang electrical box with min. 2-1/2 depth.
    2. For surface mounting, install sub station in the SBX-2G surface mount enclosure. 
    3. IMPORTANT!These units are designed for use in normal weather conditions, and to allow drainage and 
    evaporation of moisture that naturally gets into the unit. Do not apply caulking or silicone sealant around the 
    unit when installing, and do not use weather stripping around the perimeter of the box when mounting.If 
    sealing the unit is required, the bottom must remain unsealed.Sealing the unit will prevent or inhibit moisture from 
    dissipating from inside the unit, which may cause corrosion or deterioration to the internal components over time.
    Do not apply 
    sealant between 
    unit and box.
    Pg. 1
    IE-SS/A / IE-SSR
    Red
    Blk
    NOTE:
    1 PS-2420UL per system 
    when all subs are audio-only. 
    If any video door stations are 
    on the system, 2 PS-2420UL 
    power supplies are required.
    CAT-5e
    CAT-5e
    Note: Wire from sub can be 2-
    conductor, but must be spliced to 
    CAT-5e with RJ-45 jack at CEU.
    AX Central Exchange Unit
    Homerun each sub to 
    AX-084C, AX-248C, or 
    AX-320C CEU.
    Red
    Blk
    IE-SS/A / IE-SSR
    TIA/EIA 568B Standard:
    Connect 3/6 pair (green) to “Red”
    Connect 7/8 pair (brown) to “Black”CAT5e
    Illustration of converting from 
    2-conductor to CAT-5e cable.
    Use your preferred method for splicing cables to 
    interface a standard 2-conductor cable run from 
    the door station to the CAT-5 cable and RJ45 
    jack, required for connection to the CEU.
    IE-SS/A IE-SSR 
    						
    							Aiphone Communication Systems
    1700 130th Ave. N.E.
    Bellevue, WA  98005
    (425) 455-0510
    FAX (425) 455-0071IE-SS/A, IE-SSR Instr.
    0711JD
    SPECIFICATIONS:
    Power Source: Supplied by master station
    Speaker: Baffle protected, Water proof and puncture resistant, 2.4 oz. magnet
    Microphone: Baffle protected
    Call Button: SPST call button. Call tone is activated at master when call button is pressed
    IE-SS/A: Limited stop button. IE-SSR: Limited stop, red mushroom button
    Communication: Hands free at sub.  Master uses handset.
    Faceplate: 12 gauge stainless steel
    Mounting: Flush mount into a 2-gang box. Surface mount into SBX-2G, sold separately.  
    Tamper proof screws included (6x32 for use with flush gang box) with T-10 TORX bit.
    Use hardware included with SBX-2G when installing sub into that unit. 
    Terminations: Color-coded prewired pigtails
    Operating Temperature: Flush Switch rating: 14°F to 158°F; Mushroom Switch rating: -22°F to 185°F
    Speaker rating: -67°F  to 187°F
    Wiring: 2 conductors. Use Aiphone #822202
    Wiring Distance: See system that unit is being used with for distance specifications
    Dimensions (H x W x D):  IE-SS/A / IE-SSR alone:  4-11/16 x 4-11/16 x 2
    With SBX-2G:  4-3/4 x 4-7/8 x 3-5/8 (Top) 2-3/8 (Bottom)
    +
    - WIRING DIAGRAM (TD-H Series):
    1*
    ~
    24
    C
    D
    +
    -
    TD-H Master
    PS-1225UL
    Red
    Blk
    IE-SS/A / IE-SSRC
    1
    2
    D
    +
    -
    DE-URTD-H Masters:
    TD-3H/B
    TD-6H/B
    TD-12H/B
    TD-24H/B
    NOTES:
    1. The TD-1H/B does not have a “D” terminal for use with a door station. 
    2. Max. two door stations can be used on the TD-H/B system, each requiring a DE-UR. Set A-B switch on 
    each one to differentiate intermittent tremolo tone when doors call in.
    2. Refer to the standard TD-H/B instructions for complete installation and wiring information.
    ~
    ~
    1/D1
    2/E1
    +
    -
    IE-series IE-SS/A / IE-SSR
    PT-1210N
    Red
    BlkIE Series 
    2-door systems:
    IE-2AD
    IE-8MD
    ~
    ~
    D1
    E1
    D2
    E2
    +
    -
    IE-series IE-SS/A / IE-SSR
    PT-1210N
    Red
    Blk
    IE-SS/A / IE-SSR
    Red
    Blk WIRING DIAGRAM (IE Series):IE Series 
    1-door systems:
    IE-1AD (1 / 2)
    IE-1GD (D1/E1)
    * Connect to desired station number, 1 ~ 12.
    TOLL FREE TECHNICAL SUPPORT:
    (800) 692-0200
    E-MAIL: [email protected] 
    						