Home > Aiphone > Telephone > Aiphone IS IP Network Direct Install Manual

Aiphone IS IP Network Direct Install Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Aiphone IS IP Network Direct Install Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 161 Aiphone manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation, 
    and keep it in a safe place for future reference.
    Also read the SETTING MANUAL and OPERATION MANUAL on the CD-ROM included with the IP master station (IS-IPMV).
    * Refer to the manuals for the standard (IP) system as needed.
    When the installation is completed, confi gure the system by following the SETTING MANUAL. Otherwise, the system will be non-
    functional.
    IMPORTANT
    Do not install the system until you have completely understood the system and this manual.• 
    The system must be installed and wired by a qualifi ed technician well-versed in network construction.• 
    Please note that the illustrations in this manual may differ from the actual ones.
    IS SERIES
    Commercial & Security IP Video Intercom system
    Network Direct System
    INSTALLATION MANUAL
    FK1628  B   P0811JZ 
    						
    							2
    CONTENTS
    PRECAUTIONS ................................ 3
    WARNING ....................................... 3
    CAUTION ........................................ 3
    GENERAL PRECAUTIONS ............ 3
    Notes on using this system .......... 4
    Notices ............................................ 4
    SYSTEM CONFIGURATIONS 
    AND CONNECTIONS ...................... 4
    Entire system  ................................ 4
    Network direct system 
    connection diagram ....................... 5
    Cables ............................................. 6
    UNIT DETAILS  ................................ 7
    Color monitor IP master station 
    (IS-IPMV) ......................................... 7
    ■ Accessories .......................................... 7
    ■ Mounting ............................................... 7
    ■ Connections ......................................... 8
    IP vandal-resistant video door 
    station (IS-IPDV, IS-IPDVF) ............ 9
    ■ Accessories .......................................... 9
    ■ Mounting locations
     ................................... 9
    ■ Mounting positions and image view 
    area of IP video door station ................ 9
    ■ Mounting ............................................. 10
    ■ Connections 
    (IS-IPDV and IS-IPDVF) .....................11
    TECHNICAL DATA AND 
    PRECAUTIONS .............................. 12
    WARRANTY ................................... 13
    ABOUT THIS MANUAL
    The IS system provides various manuals to meet various system planning and work processes. Use the manuals necessary for your 
    system.
    Manual confi gurations
    The following manuals are provided for a network direct system. Read all the manuals for installing, setting up, and using a network 
    direct system, or provide the manuals to the persons working with the system.
    *  These manuals may also be needed when installing an IP master station or IP video door station in a standard (IP) system.
    INSTALLATION MANUAL (This manual included with the IP master station (IS-IPMV))
    Used for installing and connecting stations. (For an installer or serviceman)
    SETTING MANUAL (An electronic manual on the CD-ROM included with the IP master station (IS-IPMV))
    Used for making the system settings and system maintenance. (For an installer or serviceman)
    OPERATION MANUAL (An electronic manual on the CD-ROM included with the IP master station (IS-IPMV))
    This manual describes how to use this system for calling, communicating, paging, monitoring, etc. (For users of the 
    system)
    *  If you will use these products in a standard (IP) system, also refer to the INSTALLATION MANUAL, SETTING MANUAL and 
    OPERATION MANUAL on the CD-ROM included with an IP control unit (IS-IPC).
    After unpacking, check the included parts for each product 
    referring to the corresponding pages. 
    						
    							3
    PRECAUTIONS
     General Prohibitions     Prohibition to Dismantle the Unit     Prohibition on Subjecting the Unit to Water    
     General Precautions  
    WARNING
    Negligence could result in death or serious injury.
    1. Do not dismantle or alter the unit. Fire or electric shock could 
    result.
    2. Keep the unit away from water or any other liquid.
    Fire or electric shock could result.
    3. High voltage is present internally. Do not open the case. 
    Electric shock could result.
    4. The unit is not of explosion-proof. Do not install or use near 
    gases or fl ammable materials. Fire or explosion could result.
    5. Do not connect any non-specifi ed power source to the +, - 
    terminals. Also, do not install two power supplies in parallel to a 
    single input. Fire or damage to the unit could result. Be sure to 
    connect a single power supply unit to the unit.
    6. Do not connect any terminal on the unit to an AC power line. 
    Fire or electric shock could result.
    7. Do not use power supply with a voltage other than specifi ed. 
    Fire or electric shock could result.
    8. Keep AC cord from being marred or crushed. If the AC cord is 
    fractured, fi re or electric shock could result.
    9. Do not plug or unplug with wet hands. Electric shock could 
    result.
    10. Insert AC plug completely and securely into AC outlet. 
    Otherwise, fi re or electric shock could result.
    11. Do not put any metal or fl ammable material into the unit 
    through the openings. Fire, electric shock, or unit trouble could 
    result.
    12. The unit must be installed and wired by a qualifi ed technician.
    13. Existing wiring such as chime wiring, etc. may contain high 
    voltage AC electricity. Damage to the unit or electric shock 
    could result. Wiring and installation should be done by a 
    qualifi ed technician.
    CAUTION
    Negligence could result in injury to people or damage to property.
    1.Do not install or make any wire terminations while power supply 
    is plugged in. It can cause electrical shock or damage to the unit.
    2. When mounting the unit on a wall, install the unit in a 
    convenient location, but not where it could be jarred or 
    bumped. Injury could result.
    3. Before turning on power, make sure wires are correctly 
    connected, not crossed or not shorted. If not, fi re or electric 
    shock could result.
    4.Do not install the unit in locations subject to frequent vibration or 
    impact. It may fall or tip over, resulting in damage to the unit or 
    personal injury.
    5. For power supply, use Aiphone power supply model or model 
    specifi ed for use with system. If non-specifi ed product is used, 
    fi re or malfunction could result.
    6. On products with ground terminals, connect to an earth ground. 
    Fire or malfunction could result.
    7. Do not put high pressure on the monitor. If fractured, injury 
    could result.
    8. If LCD is punctured, do not allow contact with the liquid crystal 
    inside. Infl ammation could result. If necessary, gargle your 
    mouth and clean your eyes or skin with clear water for at least 
    15 minutes, and consult your doctor.
    9. Do not put anything on the unit or cover the unit with cloth, etc. 
    Fire or unit trouble could result.
    10. Do not install the unit in any of the following locations. Fire, 
    electric shock, or unit trouble could result.
    Places under direct sunlight or places near heating  * 
    equipment that varies in temperature.
    Places subject to dust, oil, chemicals, hydrogen sulfi de (hot  * 
    spring).
    Places subject to moisture and humidity extremes, such as  * 
    bathrooms, cellars, greenhouses, etc.
    Places where the temperature is quite low, such as inside a  * 
    refrigerated area or in front of an air conditioner.
    Places subject to steam or smoke (near heating or cooking  * 
    surfaces).
    Where noise generating devices such as dimmer switches or  * 
    inverter electrical appliances are closeby.
    Locations subject to frequent vibration or impact. * 
    11. Do not use the handset when you perform a call test or check 
    the volume, otherwise it may cause damage to your ear. Be 
    sure to use the built-in speaker.
    12. Be sure to perform a call test or check the volume with the 
    handset on the hook. If you operate the hook switch with the 
    handset on your ear, a sudden call etc. may arrive causing 
    damage to your ear.
    GENERAL PRECAUTIONS
    1. Keep the unit more than 1 m (3.3) away from radio or TV.
    2. Keep the intercom wires more than 30cm (12)  away from AC 
    100-240V wiring. AC induced noise and/or unit malfunction could 
    result.
    3. Install the unit in an area that will be accessible for future 
    inspections, repairs, and maintenance.
    4. As to other manufacturer’s devices (such as door releases) used 
    with this system, comply with the Specifi cations and Warranty 
    conditions that the manufacturers or venders present.
    5. If the unit is down or does not operate properly, unplug the power 
    supply.
    6. If it is used close to a cellular phone, the unit may malfunction.
    7. The unit can be damaged if dropped. Handle with care.
    8. The unit turns inoperative during power failure.
    9. In areas where broadcasting station antennas are close by, the 
    intercom system may be affected by radio frequency interference.
    10. All the units, except for door station, is designed for indoor use 
    only. Do not use outdoor.
    11. This product, being a control unit of door release, should not be 
    used as a crime prevention device.
    12. It must be noted in advance that the LCD panel, though 
    manufactured with very high precision techniques, inevitably will 
    have a very small portion of its picture elements always lit or not lit 
    at all. This is not considered a unit malfunction.
    13. Door station is weather-resistant, but do not spray with high-
    pressure water. Unit trouble could result.
    14. For wiring, specify CAT5e/6 straight cable. 
    						
    							4
    SYSTEM CONFIGURATIONS AND CONNECTIONS
    The IS system is a commercial and security video intercom system especially designed for applications in facilities such as offi ce 
    buildings, factories, schools, hospitals, and prisons. Installed separately from conventional general-purpose internal communications 
    systems, the IS system can be used as a video door entry system, emergency announcement system, rescue assistance system, 
    urgent call system, public announcement system, and access control system.
    The IS system can be constructed on an IP network so multiple sites of IS system can be connected and controlled as a global 
    system. You can design the system to any scale depending on your needs. 
    Entire system 
    You can construct a large-scale IS system by connecting up to 32 sites (a site can consist of up to 32 IP units) on an IP network. In 
    this system, calling, communication, etc. are possible among sites.
    Site 1
    Site 2
    Site 3Site 4Site 32 15. Due to the environmental sound around the unit, it may hinder 
    smooth communication, but this is not a malfunction.
    16. When outside temperature lowers sharply after rainfall, etc., the 
    inside of camera may fog up slightly, causing a blurry picture, but 
    this is not a malfunction. Normal operation will be restored when 
    moisture evaporates.
    17. Do not locate the units in a location with restricted access. It 
    impedes maintenance inspection or repairs. Also, unit trouble 
    could result.
    Notes on using this system
    The ID/Password to access the web server for setting the system • is the customers responsibility. Make sure you set a password that 
    cannot be easily guessed by a third party. We recommend that you 
    change the ID/Password on a regular basis.
    Notices
    We will under no conditions be liable for damage that occurs due • to failures in network equipment; failures due to internet providers 
    and cell phone companies; failures such as disconnected lines and 
    other losses in communication, which render it impossible to provide 
    this service or in any way delay this service due to causes outside 
    of our responsibility; or if an error or missing data occurs during 
    transmission.We will under no conditions be liable for damage that occurs due 
    • to the inability to communicate due to malfunctions, problems, or 
    operational errors in this product.
    We will under no conditions be liable for damage caused if a 
    • customers password or transmitted information are leaked through 
    bugging or unlawful computer access over Internet communication.
    We will under no conditions be liable for any damages or losses 
    • resulting from this products contents or specifi cations.
    This manual was created by Aiphone Co., Ltd., all rights reserved. 
    • Copying a part of or this entire manual without prior permission from 
    Aiphone Co., Ltd. is strictly forbidden.
    Please note that images depicted in this manual may differ from the 
    • actual images.
    Please note that this manual may be revised or changed without 
    • prior notice.
    Please note that product specifi cations may be changed for the sake 
    • of improvement without prior notice.
    Please be aware that it is the customers responsibility to ensure that 
    • their computer is secure. We will under no conditions be liable for 
    security failures.
    This system is not intended for life support or crime prevention. It is 
    • just a supplementary means of conveying information. Aiphone will 
    under no conditions be liable for loss of life or property which occurs 
    while the system is being operated. 
    						
    							5
    Network direct system connection diagram
    The following is an example of network direct system for controlling security and communication for facilities.
    A site must be confi gured with an IP-based system. 
    • 
    A network direct system can consist of IP units.• 
    An IP unit (PC master station, IP door station or IP master station) can be connected directly to a LAN.• 
    In a site, up to 32 IP units can be connected.• 
    IS-IPMV
    IS-IPDV
    /IS-IPDVF
    PT
    PS-2420/D/UL/S*1PS-2420/D/UL/S*1
    PoEPoE
    IS-IPDV
    /IS-IPDVF
    PT
    PS-2420/D/UL/S*1
    PoE
    Network direct system: Control offi ce, etc.
    Internet / WAN Site 1
    Site 2Site 3Site 32
    AC 
    transformerAC 
    transformer
    oror or
    LAN (IP network)
    PC master station
    (IS-SOFT)
    Audio 
    recorderSwitch (Hub) Switch (Hub)Switch (Hub) Switch (Hub)
    EL-12S
    Electric door strikeEL-12S
    Electric door strike
    : IS system product
    *1: Do not use PS-2420S in Europe.
    Maximum number of units connectable to a site of network direct system
    Category Model name TypeMax. number
    IPMaster stationIS-IPMV Color monitor IP master station32*2IS-SOFT (PC master station) PC master station
    Sub stationIS-IPDV IP vandal-resistant video door station (surface-mount)
    IS-IPDVF IP vandal-resistant video door station (fl ush-mount)
    *
    2:  Up to 31 PC master stations (IS-SOFT) can be connected within an IP network per site. If you do so, at least one color monitor IP master station 
    (IS-IPMV) or IP vandal-resistant video door station (IS-IPDV or IS-IPDVF) must be also connected. (A site of network direct system cannot consist 
    of PC master stations (IS-SOFT) only.) 
    						
    							6
    Cables
    Cables and connectors are not included with the products.
    Refer to page 7 to 11 for details about each unit connection.
    Notes on cables
     
    Pair4
    Pair3
    12345678 12345678
    Pair2
    Pair1
    T568A
    Pair4
    Pair2Pair3
    Pair1
    T568B
    How to connect or disconnect stranded wires.
    8mm(3/8")
    Notes on CAT5e/6 cables
    Do not bend the cables to an extent where the radius is • less than 25 mm (1”). Communication failure could result.
    Do not remove the CAT5e/6 cable jacket more than 
    • necessary.
    Odd number cables, such as • three conductor wire, cannot be 
    used. Unless otherwise noted, never use individual • conductors, twisted pair cable or coaxial cable.
    CAT5e/6 cable
    25mm (1) or more
    Less than 25mm (1) CAT5e/6 cableArrange the color code of the RJ45 connections in accordance 
    • with EIA/TIA-568A or 568B.
    Be sure to check the condition of cable connections with a 
    • LAN checker before connecting with a LAN cable.
    An RJ45 connector with a cover cannot be connected to the port 
    • for CAT5e/6 on IP master stations or IP door stations. Use a cable 
    without a cover.
    Do not pull or put excess strain on CAT5e/6 cables.
    • 
    Use a straight-through cable for connecting units. Use a • crossover cable when connecting with a PC directly.
    e.g.) IS-IPMV (back)
    Release button
    Twist the strands together, then insert the • wire into one of the quick coupling terminals.
    To ensure that the wire wont bend, press the release button while inserting into terminal.
    •  
    						
    							7
    Color monitor IP master station (IS-IPMV)
    For the part names and their functions, see the OPERATION MANUAL.* 
    ■ Accessories
    ~Mounting bracket × 1
    ~Screw (15mm (5/8), for wall-mounting) × 4
    ~Desktop stand × 1
    ~Screw (25mm (1), for gang box) × 4
    ~Tie-wrap × 1
    ~Screw (10mm (7/16), for desktop stand) × 4
    ~Name plate × 1
    ~Installation manual (a booklet in English) × 1
    ~Name card × 1
    ~CD-ROM (Installation manual, Setting manual and Operation manual) × 1
    ~China RoHS paper × 1
    ■ Mounting
    When mounting on a wall
    
    
    UNIT DETAILS 
    Mounting bracket 
    (attached to the unit with shipment)
    Mounting bracket 
    (attached to the unit with shipment) 3-gang box
    The unit
    Screw (for gang box) × 4 (included)
    Option wires (and power wires)
    CAT5e/6 cable
    83.5mm (3-5/16) 92mm (3-5/8)
    NOTE:
    A single-gang box can also be 
    used for wiring. When using 
    a single-gang box, fasten the 
    mounting bracket to the wall 
    directly by using the screw holes 
    for 3-gang box.
    Screw (for wall-mounting) × 4 (included)
    The unit
    Fasten the mounting 1 bracket to the wall.
    Connect the CAT5e/6 cable 2 and option wires to the unit.
    Mount the unit on the 3 mounting bracket.
    Connect the CAT5e/6 cable and option wires 
    to the unit and route them as shown.
    Filling in the target names on 
    the name card
    1  Remove the transparent name plate by 
    pushing either upper or lower side of the 
    plate.
     
    * Remove the name card if necessary.
    2  Fill in the target names on the white 
    space of the name card.
    3  Replace the name plate.
    *2: The name plate and name card are 
    attached to the unit with shipment.
    Name card × 1 (included*2)
    Name plate × 1 (included*
    2) 
    						
    							8
    When mounting on a desktop stand
    30r
    45r
    60r
    ■ Connections
    LAN/PoE
    AAAUDIO
    OUTPUT
    DC24V
    P
    CAT5e/6
    NP
    *1:  A power supply unit is not needed when using a switch or injector that has a PoE (Power over Ethernet) function. The unit is supplied with power 
    along with data signal via a LAN cable.
    NOTES:
    Do not use the unoccupied terminals and ports for other purposes.
    In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
    For connecting other manufacturer’s products, refer to the instruction manuals for those products.
    The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.
    NOTES:
    Attach the screws to the screw holes for 3-gang box on the mounting bracket to make both 
    
    sides of the mounting bracket contact the desktop stand.
    If necessary, secure the CAT5e/6 cable with the tie-wrap (included).
    
    The unit
    Screw (for desktop stand) × 4 
    (included)
    Desktop stand
    (included)
    Set up the desktop 1 stand.
    Set up the desktop stand on  * 
    a level surface etc. so that it 
    is stabilized. Fix the desktop 
    stand in place if needed.
    The desktop stand allows you  * 
    to adjust it in 3 setup angles.
    Put the leg in a groove on the 
    base that corresponds to the 
    desired angle.Fasten the mounting 2 bracket to the desktop 
    stand.
    Connect the CAT5e/6 cable 3 and option wires to the unit.
    Mount the unit on the 4 mounting bracket.
    Leg
    Base
    Audio output 
    (50mVrms, 600Ω)
    Audio 
    recorder, etc.
    (non-shielded)
    Switch (Hub)
    Power supply unit *1
    (PS-2420/D/UL/S)
    Mounting bracket 
    (attached to the unit 
    with shipment)
    Option wires (and power wires)
    CAT5e/6 cable
    15m (50) 100m (330) 15m (50)
    φ
    0.65-1.2 (22-16AWG)-2C 10BASE-T/100BASE-TX φ
    0.65-1.2 (22-16AWG)-2C
    NP: Non-polarized
    P: Polarized 
    						
    							9
    IP vandal-resistant video door station (IS-IPDV, IS-IPDVF)
    ■ Accessories
    ~Screw (for wall-mounting) × 4 (IS-IPDV only)
    ~Special screwdriver × 1
    ~Anchor × 4 (IS-IPDV only)
    ~Back box × 1 (IS-IPDVF only)
    ~Transparent name plate × 2
    ~China RoHS paper × 1
    ~Special screw × 4 (IS-IPDVF only)
    ■ Mounting locations
    Do not install this unit in any of the following locations where lighting or the ambient environment could impact the display on the 
    video monitor due to the characteristics of the door stations camera.
    a  Locations subject to 
    direct sunlightb  There is a white wall behind 
    the callerc  Other locations subject to strong 
    lighting or backlighting conditions
    ■ Mounting positions and image view area of IP video door station
     Wide picture
      An area over a range of approx. 170°  in a 500 mm 
    (20) radius from the camera displays.
      (The display range is a rough estimation and may 
    change due to the installation environment.)
    Up/DownMounting position
    1,500 mm (5)Mounting position 
    1,300 mm (4 3)
    Left/Right
    Unit centerApprox. 1,050 mm (3 5) Approx. 2,050 mm (6 9)
    Approx. 1,000 mm (3 4)
    1,500 mm (5)
    500 mm (20)
    500 mm (20)
    Approx. 170°
    Approx. 1,050 mm (3 5) Approx. 1,850 mm (6 1)
    Approx. 800 mm (2 7)Unit center
    1,300 mm (4 3)
    500 mm (20)
    Up/Down
    Left/Right
    Zoom 
    Unit center
    Approx. 2,300 mm (7 7)
    Approx. 850 mm (2 9)
    Approx. 1,450 mm (4 9)
    500 mm 
    (20)1,500 mm (5)Zoom Approx. 750 mm (2 5) Approx. 1,600 mm (5 4)
    Approx. 850 mm (2 9)
    500 mm (20)
    Unit center
    1,500 mm (5)
    Zoom 
    500 mm (20)
    Approx. 100 mm (4)
    Approx. 1,300 mm (4 3)
    Zoom 
    500 mm (20)
    Approx. 900 mm (3)
    Zoom 
    500 mm (20)
    Approx. 1,300 mm (4 3) Approx. 100 mm 
    (4)
     Wide picture
     Zoom picture
      The zoom position can be changed.
      (Refer to the OPERATION MANUAL.)
      The factory setting is Center for Zoom mode.Approx. 
    1,050 mm
    (3 5)
    Approx. 700 mm (2 3)
    Approx. 900 mm (3)
     Objects appear 
    smaller due to 
    greater distortion 
    in the surrounding 
    sections compared to 
    the central section, 
    but a wider area is 
    displayed.
      The display range is 
    a rough estimation 
    and may change due 
    to the installation 
    environment.
     Zoom picture (when mounting position is 1,500 mm (5))
    Zoom 
    1,500 mm (5)
    Approx. 1,900 mm (6 3)
    Approx. 700 mm (2 3)
    Approx. 1,200 mm (3 11)Unit center
    500 mm (20) 
    						
    							10
    ■ Mounting
    IS-IPDV (surface-mount)
    ABCDEFG
    IS-IPDVF (fl ush-mount)
    Special 
    screwdriver
    (included) Loosen
    Tighten
    Vandal-resistant 
    front panel
    81 mm (3-1/4)
    194 mm (7-11/16)
    Water escape holes
    Do not block the holes.
    Ø 6 mm
    (Ø 1/4)35 mm
    (1-3/8)
    Anchor x 4 
    (included)Screw mounting 
    hole x 4
    To insertion openingTo  
    insertion 
    opening
    NOTE
    Make room for threading a screw.
    1  Peel off the protective seals on the plate (both sides).
    2  Fill in the name on the transparent name plate.
     Be sure to leave 25 mm (1) of white space on the 
    right end to account for insertion.
    3 Insert the fi lled-in transparent name plate at the 
    specifi ed insertion opening (indicated with 
     in 
    diagram).
    2 mm (1/8)25 mm
    (1)
    Mounting height
    GL=1,500 mm (5)
    Tighten
    Special screw x 4 
    (included) Vandal-resistant front panel with the unit attachedFlush mount back box (included)
    Transparent name plate45 mm
    (1-13/16) 120 mm
    (4-3/4)
    235 mm
    (9-5/16)
    90 mm (3-9/16) 
    25 mm (1) 
    25 mm (1) 
    Unit center
    Unit 
    center
    The unit
    Screw (for wall-mounting) × 4 
    (included)
    Loosen the screw 1 with the special 
    screwdriver, and 
    remove the front 
    panel.
    Insert the transparent name plate.
    2 (IS-IPDV and IS-IPDVF)Open the terminal cover, and 
    3 connect the CAT5e/6 cable and 
    option wires to the unit. Fasten the unit to the 
    4 mounting surface.
    Use board anchors or concrete * plugs as needed.
    Attach the front panel to the unit by 5 hanging the upper 2 parts on the unit.
    Tighten the screw with the lower part of * the front panel pressed to the wall.
    Mounting height (box center)
    GL=1,500 mm (5)Loosen
    Special screwdriver
    (included)
    Install the back box in the wall, and 1 then connect the CAT5e/6 cable 
    and option wires to the unit with the 
    terminal cover open.
    Insert the transparent name plate. 
    2 See above for details.* 
    Fasten the front panel to the 3 back box with the special screws.
    Option wires 
    (and power wires)
    CAT5e/6 cable 
    						
    All Aiphone manuals Comments (0)