Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation, 
and keep it in a safe place for future reference.
Also read the SETTING MANUAL and OPERATION MANUAL on the bundled CD-ROM.
When the installation is completed, confi gure the system by following the SETTING MANUAL. Otherwise, the system will be non-
functional.
IMPORTANT
Do not install the system until you have completely understood the system and this manual.• 
The system must...

Page 2

2
CONTENTS
PRECAUTIONS ................................ 3
WARNING ....................................... 3
CAUTION ........................................ 3
GENERAL PRECAUTIONS ............ 3
Notes on using this system .......... 4
Notices ............................................ 4
SYSTEM CONFIGURATIONS .......... 4
Entire system  ................................ 4
System confi guration examples .... 5
■ Standard (IP) system ............................ 5
CONNECTIONS  .................................

Page 3

3
PRECAUTIONS
 General Prohibitions     Prohibition to Dismantle the Unit     Prohibition on Subjecting the Unit to Water    
 General Precautions  
WARNING
Negligence could result in death or serious injury.
1. Do not dismantle or alter the unit. Fire or electric shock could 
result.
2. Keep the unit away from water or any other liquid.
Fire or electric shock could result.
3. High voltage is present internally. Do not open the case. 
Electric shock could result.
4. The unit is not of explosion-proof. Do...

Page 4

4
SYSTEM CONFIGURATIONS
The IS system is a commercial and security video intercom system especially designed for applications in facilities such as offi ce 
buildings, factories, schools, hospitals, and prisons. Installed separately from conventional general-purpose internal communications 
systems, the IS system can be used as a video door entry system, emergency announcement system, rescue assistance system, 
urgent call system, public announcement system, and access control system.
The IS system can be...

Page 5

5
System confi guration examples
■ Standard (IP) system
The following is an example of standard (IP) system for controlling security and communication for facilities.
A site must be confi gured with an IP-based system. 
• 
A standard (IP) system can consist of local systems and IP units.• 
A local system (Hard wired network system) without connecting to an IP network can also be an independent system.• 
When using a local system as an independent system, it needs at least one central control unit (IS-CCU)....

Page 6

6
CONNECTIONS 
System connection diagram
The following is an example of standard (IP) system connection diagram.
Refer to page 9 to 26 for details about each unit connection. * 
IPIS-IPC*1
IS-CCU
IS-RCUIS-SCU
IS-RSIS-RS IS-RS IS-MV
IS-DV/IS-DVF
/IS-SS
IS-DV/IS-DVF
/IS-SS IS-MV
PT
PT IS-SS
IS-PU-UL
IS-PU-S
IS-PU-UL
IS-PU-S
IS-PU-UL
IS-PU-SIS-PU-UL
IS-PU-S
Local system
(Max.8)
(Max. 8)
(Max. 4)(Max. 4)
(Max. 2) (Max. 4)
(Max. 1)
(Max. 30)
To Internet/WAN
Monitor
MonitorRecorderRecorder Broadband 
router...

Page 7

7
IP
IP
IS-IPC*1
IS-RCU
IS-RS IS-IPMV
IS-IPDV
/IS-IPDVF
IP
PTIS-SS
IP
PS-2420/D/UL/S*2PS-2420/D/UL/S*2
IS-PU-UL
IS-PU-S
IS-PU-UL
IS-PU-SPoEPoE
AC 
transformer
Maximum number of each unit connectable to a local system and a site of standard (IP) system
Category Model name TypeMax. number
Local system  Standard (IP) system
LocalControl unitIS-CCU Central control unit 1 8*4
IS-SCU Add-on control unit 2 16
IS-RCU Room sub control unit 4 32
Master station IS-MV Color monitor master station 20 160
Sub...

Page 8

8
Cables
Cables and connectors are not included with the products.
Refer to page 9 to 26 for details about each unit connection.
Notes on cables
 
Pair4
Pair3
12345678 12345678
Pair2
Pair1
T568A
Pair4
Pair2Pair3
Pair1
T568B
How to connect or disconnect stranded wires.
8mm(3/8")
Notes on CAT5e/6 cables
Do not bend the cables to an extent where the radius is • less than 25 mm (1”). Communication failure could result.
Do not remove the CAT5e/6 cable jacket more than 
• necessary.
Odd number cables, such...

Page 9

9
UNIT DETAILS 
Control unit common information
The information on this page is common to Central control unit (IS-CCU), Add-on control unit (IS-SCU), Room sub control unit (IS-* 
RCU) and IP control unit (IS-IPC).
■ Accessories
~Mounting bracket × 2
~Installation manual (a booklet)*1 × 1
~Screw (for wall-mounting) × 4
~CD-ROM (Installation manual, Setting manual and Operation manual)*2 × 1
~Screw (for rack-mounting) × 4
~China RoHS paper × 1
~Screw (for fi xing mounting bracket) × 6
■ Mounting...

Page 10

10
Central control unit (
IS-CCU)
■ Part names
NOTE:
The illustration of the unit may differ from the actual one.
■ Specifi cations
Central control unit (IS-CCU)
Power source 48V DC (supplied from the power supply unit)
Current consumption Max. 800mA
Ambient temperature 0 - 40°C (+32°F - +104°F)
Talk channels
~Video 
channelsLocal system: 2 talk & 2 video channels, 
1 chime
Master station(s) Max. 4
Video door station(s)
Max. 4 Audio door station(s)
Room sub station(s)
Add-on control unit Max. 2
Room sub...