    							IS-DVF-2RA
    Stainless Steel Flush Mount Video Door Station with 
    Standard & Emergency Call Buttons
    -INSTRUCTIONS-
    Pg.1
    The IS-DVF-2RA is a stainless steel flush mount video door station with standard and emergency 
    call buttons.  The unit is equipped with ADA compliant lettering and Braille signage for both the 
    standard and emergency buttons.  A call status indicator is included to meet ADA rescue assistance 
    requirements.  The IS-DVF-2RA must connect to the IS-CCU or IS-SCU control units.
    1
    2
    3
    4
    5
    6
    7
    8
    9
    IS-DVF-2RANAMES & FUNCTIONS: 
    1. Camera     6. Call status indicator
    2. Microphone   7. Signage with Braille
    3. LED Light     8. Call button
    4. Speaker     9. Emergency button
    5. Name Placard
    FEATURES: 
    • Audio communication with visual indentification 
    of calling area
    • Two call buttons: Standard and Emergency
    • ADA compliant lettering and Braille signage
    • LED call status indicator
    • CCTV input
    • Red mushroom button for emergency call
    • Two programmable relay outputs for activation 
    of external systems/devices
    • Name placard
    • Stainless steel faceplate with tamper resistant 
    screws
    STEADY GREEN INDICATES CALL ANSWEREDCALL
    EMERGENCY
    PACKAGE CONTENTS:
    IS-DVF-2RAVandal-resistant Door Station
    Semi-flush backbox & tamper-resistant screws
    Security Driver
    Blank nameplacard
    INSTALLATION: 
    • For flush mounting, cut a hole in the wall and 
    use supplied back box. 
    Box dimensions are: 
    11-1/16” H x 5-13/16” W x 1-3/4” D 
    • For surface mounting, use the SBX-ISDVFRA 
    surface mount box.  This box can mount to a 
    standard 1-gang box or to any flat surface. 
    						
    							Pg. 2IS-DVF-2RA Instr.0411JD
    Aiphone Corporation1700 130th AVE NE * Bellevue, WA 98005Ph: (800) 692-0200 * Fax: (425) [email protected]
    WIRING DIAGRAM:
    IS-DVF-2RA
    IS-CCUIS-MV
    IS-PU-UL
    N/O Dry Contact 0.5 Amp
    CAT-5e
    CAT-5e
    NOCOMNC
    FCC WARNING:This device complies with Part 15 of the FCC rules.
    Operation is subject to the following two conditions:(1)  This device may not cause harmful interference.(2)  This device must accept any interference that may cause undesired operation.• For proper regulatory compliance, the drain wire should be disconnected at the power supply end of the cable.• Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
    TOLL FREE TECHNICAL SUPPORT:
    (800) 692-0200
    E-MAIL: [email protected]
    SPECIFICATIONS:
    Camera unit:   CMOS camera
    Scanning line:  525 lines
    Min. illumination: 5 Lux at 1’6”
    Terminations:   RJ45 jack for audio/video
         Screw terminals for door release and relay outputs
    Relay rating:   24V AC/DC 0.5A on Door station, 24V AC/DC 1.0A on relay board
    Operating Temp: 14° ~ 140°F / -10° ~ 60°C
    Wiring Distance: 980’ with Cat5e/6 cable
    Dimensions:   11-3/4” H x 7” W
    w/SBX-ISDVFRA: 11-11/16” H x 7-1/16” W x 2-13/16” D (top), 1-13/16” D (bottom)
    OFFON
    NO
    NO C
    NC
    C
    NC1 2 3 4
    RELAY BOARD WIRING AND SETTINGS:
    Relay 1 OutputN/O, COM, N/C
    Relay 2 OutputN/O, COM, N/C
    *Relay 2 External ResetConnect to N/O dry switch
    Configuration Switch See Settings to right
    OFF ONNO
    NOC
    NC
    C
    NC1 2 3 4
    Board on back of unitSee wiring below
    ON
    1234
    Default Configuration when shipped
    Optional Configuration
    Normal CallEmergency CallTalkingDoor Release
    Trigger SourceRY1 Triggered?RY1 Remains ON During Talking?RY2 Triggered?RY2 Remains ON During Talking?RY2 Requires Reset?YES
    NON/A
    YESYESYESYESYESNONO
    NONO
    N/A
    N/AN/A
    N/A
    N/AN/A
    YESYES
    ON
    1234
    Contact Technical Support if additional switch configurations 
    are required.  
    Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.  Relay 2 triggers on emergency call and remains on during communication.
    Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.  Relay 2 triggers on an emergency call and remains on during communicatio\
    n.  Relay 2 requires reset.
    Normal CallEmergency CallTalkingDoor Release
    Trigger SourceRY1 Triggered?RY1 Remains ON During Talking?RY2 Triggered?RY2 Remains ON During Talking?RY2 Requires Reset?YES
    NON/A
    YESNON/A
    N/AN/AYES
    YESYESYESYESYESN/A
    N/AN/ANONO
    YES* 
    						