    							IS-DVF-2RA-FR
    Stainless Steel Flush Mount Video Door Station with Standard & Emergency Call Buttons
    -INSTRUCTIONS-
    STEADY  GREEN INDICA TES CALL  ANSW EREDCALL
    EMERGENCY
    IS-DVF-2RA-FR
    Pg.1
    The IS-DVF-2RA-FR is a stainless steel flush mount video door station with standard and emergency 
    call buttons. The unit is equipped with signage in French for both the standard and em\
    ergency 
    buttons. A call status indicator is included to meet rescue assistance requirement\
    s. 
    The IS-DVF-2RA-FR must connect to the IS-CCU or IS-SCU control units.
    1
    2
    3
    4
    5
    6
    7
    8
    9
    IS-DVF-2RA-FR NAMES & FUNCTIONS: 
    1. Camera     
    6. Call status indicator
    2. Microphone    7. French Signage
    3. LED Light      8. Call button
    4. Speaker      9. Emergency button
    5. Name Placard
    FEATURES: 
    •  Audio communication with visual indentification 
    of calling area
    •  Two call buttons: Standard and Emergency
    •  LED call status indicator
    •  CCTV input
    •  Red mushroom button for emergency call
    •  Two programmable relay outputs for activation 
    of external systems/devices
    •  Name placard
    •  Stainless steel faceplate with tamper resistant 
    screws
    PACKAGE CONTENTS:
    IS-DVF-2RA-FR
    Vandal-resistant Door Station
    Semi-flush backbox & 
    tamper-resistant screws Security Driver
    Blank name placard
    INSTALLATION: 
    •  For flush mounting, cut a hole in the wall and 
    use supplied back box.  
    Box dimensions are:  
    11-1/16” H x 5-13/16” W x 1-3/4” D 
    •  For surface mounting, use the SBX-ISDVFRA 
    surface mount box. This box can mount to a 
    standard 1-gang box or to any flat surface. 
    						
    							Pg. 2
    IS-DVF-2RA-FR Instr.
    0716
    WIRING DIAGRAM:
    IS-DVF-2RA-FRIS-CCU
    IS-MV
    IS-PU-UL
    N/O Dry Contact 
    0.5 Amp
    CAT-5e
    CAT-5e
    NO
    COM
    NC
    FCC WARNING:This device complies with Part 15 of the FCC rules.
    Operation is subject to the following two conditions:
    (1)  This device may not cause harmful interference.
    (2)  This device must accept any interference that may cause undesired operation.
    •  For proper regulatory compliance, the drain wire should be disconnected at the power 
    supply end of the cable.
    •  Changes or modifications not expressly approved by the party responsible for 
    compliance could void the user’s authority to operate the equipment.
    SPECIFICATIONS:
    Camera unit:    CMOS camera
    Scanning line:   525 lines
    Min. illumination:  5 Lux at 1’6”
    Terminations:    RJ45 jack for audio/video
          Screw terminals for door release and relay outputs
    Relay rating:    24V AC/DC 0.5A on Door station, 24V AC/DC 1.0A on relay board
    Operating Temp:  14° ~ 140°F / -10° ~ 60°C
    Wiring Distance:  980’ with Cat5e/6 cable
    Dimensions:    11-3/4” H x 7” W
    w/SBX-ISDVFRA:  11-11/16” H x 7-1/16” W x 2-13/16” D (top), 1-13/16” D (bottom)
    OFFON
    NO
    NOC
    NC
    C
    NC1234
    RELAY BOARD WIRING AND SETTINGS:
    Relay 1 Output
    N/O, COM, N/C
    Relay 2 Output
    N/O, COM, N/C
    *Relay 2 External Reset
    Connect to N/O dry switch
    Configuration Switch  See Settings to right
    OFF ONNO
    NOC
    NC
    C
    NC1234
    Board on back of unit See wiring below
    ON
    1 234
    Default Configuration when shipped
    Optional Configuration
    Normal Call
    Emergency Call
    Talking
    Door Release Trigger Source RY1 Triggered? RY1 Remains ON 
    During Talking?
    RY2 Triggered?RY2 Remains ON 
    During Talking? RY2 Requires 
    Reset?YES
    NO N/A
    YES
    YES
    YESYES
    YES NO
    NO
    NO
    NO N/A
    N/A
    N/AN/A
    N/A
    N/A
    YES YES
    ON
    1
    234
    Contact Technical Support if additional switch configurations 
    are required.  
    Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.  
    Relay 2 triggers on emergency call and remains on during communication.
    Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.  
    Relay 2 triggers on an emergency call and remains on during communicatio\
    n.  Relay 2 requires reset.
    Normal Call
    Emergency Call
    Talking
    Door Release Trigger Source RY1 Triggered? RY1 Remains ON 
    During Talking?
    RY2 Triggered?RY2 Remains ON 
    During Talking? RY2 Requires 
    Reset?YES
    NO N/A
    YES
    NO
    N/A
    N/A N/A
    YES YES
    YES
    YES
    YES
    YESN/A
    N/A
    N/A
    NO
    NO YES*