    Have a look at the manual AirComm Corporation Bell 429 Heating System 429H201M1 Rev3 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 74 AirComm Corporation manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							HEATER SERVICE MANUAL 429H-201M-1 
    Revision 2    Page 7-1 
     
     
     
    CHAPTER 7 
    TROUBLESHOOTING 
     
    1. SYSTEM TROUBLESHOOTING 
     
    Prior to troubleshooting a defective system, it is advisable to conduct a visual inspection for 
    general condition, and obvious signs of damage or failure.  
     
    The following matrix lists the easiest checks, and the most likely problems. 
     
    Problem Probable Cause  Solution 
    No Heat 
     
     Bleed air shutoff valve not 
    open Operate heater switch to ON 
    position 
    No Heat 
     
     Heater System Control Valve 
    in the off position Operate the heater system control 
    valve to the ON position 
    No Heat 
     Shutoff valve failure  Replace shutoff valve 
    No Heat 
     HTR Circuit breaker tripped  Reset breaker 
    No Heat. Heater OVER TEMP 
    light illuminated 
     
     Malfunction of Temp Sensor 
    Switch Check switches – all switches 
    should be electrically open (See 
    figures 3.10 and 3.12) 
    No Heat. Heater OVER TEMP 
    light illuminated 
     Air blockage of heater inlet or 
    outlets Remove blockage 
    No Heat. Heater OVER TEMP 
    light illuminated 
     
     Bleed air line fitting loose 
    causing an over temperature 
    condition Check all lines and fittings for 
    security 
    HEATER DUCT HOT light 
    illuminated. Thermal Snap Switch too 
    close to duct assembly Inspect snap switches to ensure a 
    minimum 0.8 inch clearance 
    between the snap switch and the 
    duct. 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
               
    						
    							HEATER SERVICE MANUAL 429H-201M-1 
    Revision 1    Page A-1 
     
    APPENDIX A 
     
     
     
    Weight and Balance Information 
     
     
    Weight breakdown – Bell 429 Provisions: 
     
    Item Drawing Number Wt. 
    (lbs) X-Arm 
    (in) Y-Arm 
    (in) X-M 
    (in-lb) Y-M 
    (in-lb) 
           
    Misc Heater Provisions Instl 429H-514-1 2.29 163.4 -1.4 373 -3 
    Plumbing Provisions, Cabin 
    Roof to Control Valve Instl 429H-534-1 7.23 157.5 -19.0  1139  -137 
    Plumbing Provisions, Control 
    Valve to Ejectors Instl (Tubes) 429H-544-1  5.84  154.0  0.4  899  2 
    Plumbing Provisions, Control 
    Valve to Ejectors Instl 
    (Fittings) 429H-544-1 1.17 151.6 0.2 177 0 
    Electrical Provisions Instl  429H-814-1  0.11 222.0 11.0  23  1 
           
    Total (English Units)  429H-201 16.63 157.1 -8.8 2612 -137 
           
    Total (Metric Units)  429H-201 7.54 3989.7 -223.9 30095  -1577 
     