    Have a look at the manual Altinex TILT N PLUG DUAL HDMI VGA AUDIO RJ45 US POWER SILVER TNP528S User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 18 Altinex manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Tilt N Plug
    ®
     Interconnect Box User’s Guide 
    400-0567-002  
     
     
     
     
     
     
    1 
     
     
    Welcome!
    We greatly appreciate your purchase of your TNP520 Series Tilt N Plug. We 
    are sure you will find it reliable and simple to use. Superior performance for 
    the right price, backed by solid technical and customer support is what 
    ALTINEX has to offer. 
    We are committed to providing Signal Management Solutions® to our 
    customers for the most demanding audiovisual installations at competitive 
    pricing and we welcome you to join the ranks of our many satisfied 
    customers throughout the world. 
    1. Precautions and Safety Warnings 
    Please read this manual carefully before using your Tilt N Plug. Interconnect 
    Box. Keep this manual handy for future reference. These safety instructions 
    are to ensure the long life of your Tilt N Plug. and to prevent fire and shock 
    hazards. Please read them carefully and heed all warnings. 
    1.1 General 
     Unauthorized personnel shall not open the unit as there are high-voltage 
    components inside. Qualified ALTINEX service personnel or their 
    authorized representatives must perform all service. 
    1.2 Installation Precautions 
     For best results, place the Tilt N Plug in a dry area away from dust. 
     To prevent fire or shock, do not expose this unit to water or moisture. Do 
    not place the unit in direct sunlight, near heaters or heat-radiating 
    appliances, or near any liquid. Exposure to direct sunlight, smoke, or 
    steam can harm internal components. 
     Handle carefully; dropping or jarring can damage the bezel. 
     Never place fingers inside the opening on either side of the unit. This 
    action could cause injury due to sharp edges inside. 
     Do not place heavy objects on top of the Tilt N Plug. Do not use 
    excessive force to push down on the top of the unit. 
     Disconnect the power cord to turn off the power. This supplies power to 
    the socket on the pop-up panel. The power outlet should be installed 
    near the equipment and be easily accessible. 
     We recommend using wall outlets with a Ground Fault Circuit 
    Interrupter (GFCI) for maximum protection. 
     Install all cables according to the instructions found herein. Do not force 
    or pull any cable that is attached to the Tilt N Plug. 
    1.3 Cleaning 
     Surfaces should be cleaned with a dry cloth. Never use strong detergents 
    or solvents such as alcohol or thinner. Do not use a wet cloth or water to 
    clean the unit. 
    1.4 FCC Notice 
     This device complies with Part 15 of the FCC Rules. Operation is subject 
    to the following two conditions: (1) This device may not cause harmful 
    interference, and (2) this device must accept any interference received, 
    including interference that may cause undesired operation. 
     This equipment has been tested and found to comply with the limits for a 
    Class A digital device, pursuant to Part 15 of the FCC Rules. These limits 
    are designed to provide reasonable protection against harmful 
    interference when the equipment is operated in a commercial 
    environment. This equipment generates, uses, and can radiate radio 
    frequency energy and, if not installed and used in accordance with the 
    instructions found herein, may cause harmful interference to radio 
    communications. Operation of this equipment in a residential area is 
    likely to cause harmful interference in which case the user will be 
    required to correct the interference at his expense. 
     Any changes or modifications to the unit not expressly approved by 
    ALTINEX, Inc. could void the user’s authority to operate the equipment. 
     
     2. Installation Procedures 
    Step 1. Cut an opening into the table’s surface. Refer to the ALTINEX website at www.altinex.com for table cutout requirements. 
     Note: The table can be 2.50 in (64 mm) or less in thickness. Always confirm dimensions before cutting to insure that specifications have not changed.  
    Step 2. Insert the TNP520/TNP528 into the table cutout.  
    Step 3. Place the support brackets under the table and place them between the support mount grooves on the side 
    of the unit. Attach the brackets to the groove at the desired height and secure them to the bottom of the 
    table using the thumb screws provided. See Diagram 3 for details. 
    Step 4. To lower the unit, push on the top cover until it locks into place. 
    Step 5. Secure all cables to the underside of the table using the cable clamps and screws 
    included with the TNP. Pass the power cord from the bottom of the housing and 
    attach it to the table separate from the signal cables. 
     Leave enough slack in the service loop to allow for easy opening and closing, but not too much 
    as to cause excess drooping of the service loop. 
    Step 6. Connect the appropriate cables with the correct input connectors on the bottom of the unit.  
    Step 7. Once you have applied power and connected the proper cables on the bottom of the unit you may 
    raise the unit. To raise the unit into position, push down on the front of the top cover; the latching 
    mechanism will then release, allowing the pneumatic spring to raise it into position. 
    NOTE: It may be necessary to adjust the service loop of the cables for optimal performance. 
    3. Limited Warranty/Return Policies 
    Please see the ALTINEX website at www.altinex.com for details on warranty and return policies.  
    						
    							TNP520/528 User’s Guide 
    400-0567-002  
     
     
     
     
     
    2 
     
    4. Technical Specifications 
    Specifications are subject to change. See www.altinex.com for up-to-date information.
    Features/Description TNP 
    TNP 520* 
    Pass-Through AC Power 9-10 ft (2.7-3.0 m) 
      110 VAC, 60 Hz, 5 A NEMA F-M 
    Agency Approval  
      UL/C-UL Listed File E254082 
    TNP 528* 
    Audio, Video, Communication 6 ft (2 m) 
      Computer Video 15-pin HD F-M (2) 
      Computer Audio 3.5mm F-M (2) 
      HDMI HDMI F-M (2) 
      Network CAT-6 (RJ-45) F-M (2) 
      USB Type A F-M (1) 
    Pass-Through AC Power 9-10 ft (2.7-3.0 m) 
      110 VAC, 60 Hz, 5 A NEMA F-M 
    Agency Approval  
      UL/C-UL Listed File E254082 
     TNP520/   528 Models* 
    Accessories Included  
      Hardware   -Mounting screws/brackets   -Cable clamps/screws   -Fastener Tool 
    Table 1. TNP520/528 General 
     Mechanical TNP520 / 528** 
      Max. Table Thickness 2.50 in (64 mm) 
      Height, opened 5.50 in (140 mm) 
      Width 7.86 in (220 mm) 
      Depth 6.53 in (166 mm) 
      Finish TNP520,TNP528:  TNP520S,TNP528S:  Matte Black  Brushed Aluminum 
      Weight (approx.)  TNP520(S)  TNP528(S) 2.85 lb. (1.29 kg) 4.61 lb. (2.09 kg) 
      Shipping Weight 5.51 lb. (2.50 kg) 
      T° Operating  10°C-35°C 
      T° Maximum 40C 
      Humidity 90 non-condensing 
    Table 2. TNP520/528 Mechanical  
     Electrical    (Single outlet panel) TNP520 / 528 ** 
      Power Rating      (pass-through AC power) 120VAC, 60Hz, 12A total current 
    Table 3. TNP520/528 Electrical ** 
      
    ** Dimensions and ratings include models ending in C and S. * Includes models ending in S (brushed aluminum).  
    Models ending in C are customizable. 
      
    						
    							TNP520/528 User’s Guide 
    400-0567-002  
     
     
     
     
     
    3 
     
     
       
    5. About Your Tilt N Plug Interconnect Box 
       New leaf-spring replaces gas shock    Standard high-quality matte black or brushed aluminum finish 
       Pop-up dampening for smooth operation  TNP520, TNP528: Matte Black 
       Simple, drop-in installation  TNP520S,  TNP528S: Brushed Aluminum 
        Custom finishes available (contact ALTINEX for options and pricing)  
    The TNP520 and TNP528 are compact interconnect solutions designed for mounting into tables, podiums, or other furniture as part of a presentation system. 
    Inputs are accessed by pushing down on the top cover allowing the units to tilt open. The inputs are hidden by pressing down on the top cover until the 
    latching mechanism engages. In the closed positions, the top covers lie flush with the tabletop. Signals are passed through the sectional plates to the underside of 
    the table via cables with mating connectors on the opposite end. For example, an RJ-45 F input connector is terminated in an RJ-45 M connector at the end of a 
    6 ft (2 m) cable.   
    The TNP520 is empty with AC power only, but provides slots for 4 single-slot sectional plates that can be configured with various multimedia inputs. See our 
    website for all input plate options. The TNP528 is a package that covers the basic needs of many users and ships complete with 2 standard U.S. power 
    receptacles, 2 computer video (15-pin HD) plus 2 audio (3.5 mm), 2 standard HDMI, 2 network (RJ-45), and 1 USB (Type A) input connectors. All audiovisual 
    connectors have 6 ft. (2 m) cables that feed through to the bottom of the unit. 
     
     
     
    TNP520(S) 
    TNP528(S)  
    						
    							TNP520/528 User’s Guide 
    400-0567-002  
     
     
     
     
     
    4 
     
    6. Application Diagrams 
    Diagram 1: Application Diagram 
     
     
     
     
     
     
     
     
     
     
     
     
      
      
    						
    							TNP520/528 User’s Guide 
    400-0567-002  
     
     
     
     
     
    5 
     
    Diagram 2: Bezel Dimensions 
     
     
     
     
     
     
     
     
     
     
     
     
         
      
    						
    							TNP520/528 User’s Guide 
    400-0567-002  
     
     
     
     
     
    6 
     
    Diagram 3: Unit Dimensions 
     
     
     
     
     
     
     
     
     
     
     
     
         
      
    						
    							TNP520/528 User’s Guide 
    400-0567-002  
     
     
     
     
     
    7 
     
    Diagram 4: Mounting 
     
     
     
     
     
     
     
     
     
     
     
     
      
     
      
    						
    							TNP520/528 User’s Guide 
    400-0567-002  
     
     
     
     
     
    8 
     
    7. Operation 
    7.1 Opening and Closing the Tilt N Plug 
    The Tilt N Plug will open easily when the top is pressed down and then 
    released. 
    When the Tilt N Plug is not in use, simply press the top down until it is level 
    with the surface of the table and then release.  The unit will remain hidden 
    until needed again.  
    7.2 Power/Signal Connections 
    Connect external devices to the appropriate connector on the Tilt N Plug. 
    Remember, the devices plugged into the AC power connectors should not 
    draw more than 12A AC. 
     
     8. Troubleshooting Guide 
    The Tilt N Plug supplied was carefully tested and no problems were detected. However, we would like to offer the following suggestions: 
    Switcher  
    Symptom Resolution 
    Signal quality is poor.  
    1. Please make sure that the highest quality video and network cables are used. 
    2. The TNP is a passive unit and does not alter signals in any way. If there is suspected problem with the signal 
    quality, check the quality of the cables coming into and the TNP and connecting to the output of the TNP. If 
    they are of low quality or improperly assembled, this will affect the overall quality of the signal. 
    Damaged power cord 
    1. Make sure that no cable or power cord is damaged or pinched.  
    2. If there has been damage, do not use the Tilt N Plug. Please call the ALTINEX Customer Service Department at 
    (714) 990-2300 to have the unit repaired. 
    Unit raises too slowly 
    1. If the unit does not rise into position correctly, check the service loops for the signal and power cords on the 
    bottom of the unit. If the service loop is too small the cables will counteract the spring trying to raise the unit into 
    position. 
    Unit tilts up too fast 
    1. If the unit rises into position too fast, check the service loops for the signal and power cords on the bottom of the 
    unit. If the service loop is too large and the cables are putting upward pressure on the unit, the unit will tilt up too 
    fast. 
    Unit does not close all the 
    way 
    1. If the unit does not close flush with the bezel, check the service loops for the signal and power cords on the bottom 
    of the unit. If the service loop is putting upward pressure in the unit, the unit will not be able to seat all the way 
    down. 
     
     
      
    						
    All Altinex manuals Comments (0)