    							American ALDES Ventilation Corporation
    800.255.7749    •  www.aldes.us
    Zone Register Terminal (ZRT®)
    Selection Guide
    Use this table to select the appropriate Zone Register Terminal for your project.
    Reading the Model Code
    DUCT SIZE
    4 = 8” x 8” w/4” collar 6 = 10” x 10” w/6” collarVOLTAGE 
    24 = 24 VAC
    120 = 120 VAC
    SERIES
    1 = No Minimum Flow Control 2 = With Minimum Flow Control
    MAXIMUM FLOW CONTROL
     “Blank” = No Maximum Flow Control MAX = With Maximum Flow Control
    SPECIFIED CFMMAX / MIN 
    (Added to part number  when ordering)
    WIRELESS COMMUNICATION OPTIONS
    “Blank” = None WCA* = Wireless communication relay provided 
    and installed by Aldes FMA* = Communication relay provided by others 
    and installed by Aldes WCOSG = Stand-alone occupancy sensor and 
    communication relay by Aldes WCWS = Stand-alone wireless wall switch and 
    communication relay by Aldes
    *Wireless communication relays by Telkonet®, InnCom®, and Magnum Energy 
    Solutions™ only. Contact factory for availability of controls by others.
    APPLICATION
     “Blank” = Standard Ceiling Mount FR = With Ceiling Radiant Fire Damper
    W = Wall Mount
    W-FR = Wall-Mount with Fire Damper
    IL = In-Line
    S = Supply
    ExampleZRT- W -2 -4 -24 MAX -XX /XX WCA*
    MODEL NAME USE
    MOUNTING INCLUDED
    ExhaustSupplyCeiling WallIn-Line Fire Damper Grille
    
    ZRT
    X X X
    
    ZRT-S
    XX X
    
    ZRT-FR
    XX XX
    
    ZRT -FRS
    XX XX
    
    ZRT -W
    XX X
    
    ZRT-WS
    XX X
    
    ZRT-W-FR
    XXXX
    
    ZRT -W-FRS
    XX XX
    
    ZRT -IL
    XX X  
    						
    							American ALDES Ventilation Corporation
    800.255.7749    •  www.aldes.us
    Parallel Damper In-Line Zone Terminal (ZRT-PDIL) 
    Selection Guide
    Use this table to select the appropriate Parallel Damper In-Line Zone 
    Terminal for your project.
    Reading the Model Code
    DUCT SIZE
    12x6 = 12” x 6”
    16x8 = 16” x 8” 20x10 = 20” x 10”
    24x12 = 24” x 12”
    28x10 = 28” x 10”30x10 = 30” x 10”
    34x12 = 34” x 12”
    36x12 = 36” x 12”
    VOLTAGE 
    24 = 24 VAC
    120 = 120 VAC
    PRESSURE RANGE
    “Blank” = Standard Pressure HP = High-Pressure
    MAXIMUM CFM
    (BOOST 1)
     The maximum CFM  range that coordinates 
    to the desired  minimum setpoint and 
    the duct size
    MAXIMUM CFM (BOOST 2)
    3PDIL ONLY
    The maximum CFM range that  coordinates to the desired setpoint and the duct size
    MINIMUM CFM
    The desired minimum setpoint
    APPLICATION PDIL = Parallel Damper In-Line
    PDIL-HP = Parallel Damper In-Line High Pressure
    3PDIL = Three Parallel Damper In-Line
    3PDIL-HP = Three Parallel Damper In-Line High Pressure
    ExampleZRT- PDIL -HP-12x6 -24 XX /XX/XX
    MODEL NAME SETPOINTSMOUNTING STATIC PRESSURE RANGE
    Standard  
    0.2-0.8 in. w.g. High
     
    0.6-2.4 in. w.g.
    
    ZRT -PDIL
    2In-LineX
    
    ZRT-PDIL-HP
    2In-LineX
    
    ZRT-3PDIL
    3In-LineX
    
    ZRT-3PDIL-HP
    3In-LineX  
    						