American ALDES Ventilation Corporation 800.255.7749 • www.aldes.us Zone Register Terminal (ZRT®) Selection Guide Use this table to select the appropriate Zone Register Terminal for your project. Reading the Model Code DUCT SIZE 4 = 8” x 8” w/4” collar 6 = 10” x 10” w/6” collarVOLTAGE 24 = 24 VAC 120 = 120 VAC SERIES 1 = No Minimum Flow Control 2 = With Minimum Flow Control MAXIMUM FLOW CONTROL “Blank” = No Maximum Flow Control MAX = With Maximum Flow Control SPECIFIED CFMMAX / MIN (Added to part number when ordering) WIRELESS COMMUNICATION OPTIONS “Blank” = None WCA* = Wireless communication relay provided and installed by Aldes FMA* = Communication relay provided by others and installed by Aldes WCOSG = Stand-alone occupancy sensor and communication relay by Aldes WCWS = Stand-alone wireless wall switch and communication relay by Aldes *Wireless communication relays by Telkonet®, InnCom®, and Magnum Energy Solutions™ only. Contact factory for availability of controls by others. APPLICATION “Blank” = Standard Ceiling Mount FR = With Ceiling Radiant Fire Damper W = Wall Mount W-FR = Wall-Mount with Fire Damper IL = In-Line S = Supply ExampleZRT- W -2 -4 -24 MAX -XX /XX WCA* MODEL NAME USE MOUNTING INCLUDED ExhaustSupplyCeiling WallIn-Line Fire Damper Grille ZRT X X X ZRT-S XX X ZRT-FR XX XX ZRT -FRS XX XX ZRT -W XX X ZRT-WS XX X ZRT-W-FR XXXX ZRT -W-FRS XX XX ZRT -IL XX X
American ALDES Ventilation Corporation 800.255.7749 • www.aldes.us Parallel Damper In-Line Zone Terminal (ZRT-PDIL) Selection Guide Use this table to select the appropriate Parallel Damper In-Line Zone Terminal for your project. Reading the Model Code DUCT SIZE 12x6 = 12” x 6” 16x8 = 16” x 8” 20x10 = 20” x 10” 24x12 = 24” x 12” 28x10 = 28” x 10”30x10 = 30” x 10” 34x12 = 34” x 12” 36x12 = 36” x 12” VOLTAGE 24 = 24 VAC 120 = 120 VAC PRESSURE RANGE “Blank” = Standard Pressure HP = High-Pressure MAXIMUM CFM (BOOST 1) The maximum CFM range that coordinates to the desired minimum setpoint and the duct size MAXIMUM CFM (BOOST 2) 3PDIL ONLY The maximum CFM range that coordinates to the desired setpoint and the duct size MINIMUM CFM The desired minimum setpoint APPLICATION PDIL = Parallel Damper In-Line PDIL-HP = Parallel Damper In-Line High Pressure 3PDIL = Three Parallel Damper In-Line 3PDIL-HP = Three Parallel Damper In-Line High Pressure ExampleZRT- PDIL -HP-12x6 -24 XX /XX/XX MODEL NAME SETPOINTSMOUNTING STATIC PRESSURE RANGE Standard 0.2-0.8 in. w.g. High 0.6-2.4 in. w.g. ZRT -PDIL 2In-LineX ZRT-PDIL-HP 2In-LineX ZRT-3PDIL 3In-LineX ZRT-3PDIL-HP 3In-LineX