    Editing Commands
    Command format Description
    General format rthveeeyyyyxxxx See below
    Print direction r ‘1’, ’2’, ’3’ or ‘4’ (rotation)
    Object type  t ‘0’ to ‘9’ and ‘:’ (fonts) **,
    ‘A’ to ‘Z’ and ‘a’ to ‘z’ (bar
    codes),
    ‘X’   (lines or boxes),
    ‘Y’   (graphics).
    See Object Table below
    Width multiplier   h  ‘1’ to 9 and  ‘A’ to ’ O’.
    ‘0’ stands for default.
    Height multiplier     v ‘1’ to ‘9’  and  ‘A’ to ’ O’,
    ‘0’ stands for default.
    Bar code height      eee This is ignored for box, line and
    graphics.
    It represents point size for font
    ‘9’ and symbol set for Courier
    font.
    Y coordinate           yyyy
    X coordinate                  xxxx
    Data                          Depends on object types
    Note: **The model FM403TT does not include Courier fonts. 
    						
    							Users Guide 31
    Object Table
    The following table is used for the Object Type, t, in the Editing Command Table.
    Object String Description
    L : line Lwwwhhh www : width,
    hhh   : height.
    L : line Lwwwwhhhh wwww : width,
    hhhh   : height.
    B : box Baaabbbcccddd aaa :  horizontal width
    bbb : vertical height
    ccc :  thickness of top and bottom edges
    ddd : thickness of left and right bars
    B : box Baaaavvvvccccdddd aaaa :  horizontal width
    vvvv : vertical height
    cccc : thickness of top and bottom edges
    dddd : thickness of left and right bars
    bar code
    (Range ‘A’ to ‘Z’ or
    ‘a’ to ‘z’)bar code data Bar codes (and human readable text) will be
    printed according to the selected bar code
    type (‘A’ to ‘Z’ or ‘a’ to ‘z’).
    Text
    (Range ‘0’ to ‘9’)text data Text data will be printed according to the
    selected font (‘0’ to ‘9’).
    Yfile name ‘Y’ and the file that was downloaded by
    I command. 
    						
    							Users Guide 32
    Font Downloading Commands
    Such commands are only used for soft fonts with PCL format.
    Command Description
    ESC *c###D assign the soft fonts ID number (### : 100 ~ 999)
    ESC )s###W download font descriptor (### : length of font descriptor)
    ESC *c###E set character code (### : 1 ~ 255)
    ESC (s###W download character descriptor and image
    (### : length of character descriptor and image)
    Note: No spaces are after the escape character. 
    						
    							Users Guide 33
    Command Set for the PPLB
    All PPLB commands must end with  or + codes.  No spaces are allowed between
    parameters and leading command character.
    Command Description Parameter
    Ax,y,rot,font,hm,vm,nr,stringPrint text.font:  1to 5 for internal font and A to Z
    for soft font.
    Bx,y,rot,bar,nw,ww,v,hum,stringPrint Bar Code.
    bar: barcode
    selectionnw:     width of narrow bar
    ww:    width of wide bar
    v:       bar code height
    hum:  B for printing readable code
    and N for disabling.
    bx,y,type,[…]Print 2D Bar Codetype:  M for Maxi code and P for PDF
    417
    Ccn,dn,just,step,stringCounter declarationcn:    counter index
    dn:    digit number
    just:   L,R,C and N for field justification
    step:  step value
    Dp1Heat setting p1:    density, 0 to 15
    EI Print soft font
    names
    EKstringDelete soft fontstring: soft font name or “*” to delete
    all soft fonts
    ESstring,…. Download soft font
    FE End form store
    FI Print form names
    FKstringDelete formstring: form name or “*” to delete all
    forms
    FSstringExecute formstring: form name
    FSstringSave formstring: form name
    GGx,y,stringPrint graphicsstring: graphic name
    GI Print graphic list
    GKstringDelete graphicsstring: graphic name or “*” to delete
    all graphics
    GMstring,size… Store graphicsstring: graphic name
    size: graphic size in bytes 
    						
    							Users Guide 34
    Command (Cont) Description Parameter
    Ip1,p2,001 Select symbol set**p1:    7 or 8 data bits
    p2:    symbol set
    JB
    JFDisable back feed**
    Enable back feed**
    LEx,y,hlen,vlenLine draw by
    exclusivehlen:  horizontal length
    vlen:  vertical length
    LOx,y,hlen,vlenLine draw by OR
    LWx,y,hlen,vlenDraw white line
    N Clear frame buffer
    O[,C][,N][,D] Select options**
    Pp1[,p2] Print labelp1:    label set number
    p2:    copy number of each label
    PAp1[,p2] Print automatic
    Qp1,p2[,+p3]Set label and gap
    length**p1:    label length
    p2:    gap length
    p3:    offset length
    qwSet label width**w:     label width
    Rx,ySet origin point**
    Sp1Set print speedp1:   speed value, 1 to 3
    U Print configuration
    UN
    USDisable Error Report
    Enable Error Report
    Vvn,dn,just,stringDefine variablevn:   variable index
    dn:   digit number
    just:  L,R,C and N for field justification
    Xx,y,thick,ex,eyDraw boxex, ey:  end position
    thick:    line thickness
    YbaudSetup serial port**baud:   38,19,96,48 or 24
    ZT
    ZBSet print direction ZS:      print from top
    ZB:      print from bottom
    ZS
    ZNEnable/disable
    store-to-Flash++power-on default is ZN(disabled)
    ? Download variables
    or counters 
    						
    							Users Guide 35
    Command (Cont) Description Parameter
    d0,euroEnable/disable
    European dollar
    mark
    **
    0:   disable European dollar mark.
    1:   enable
    d1,hadjSet horizontal
    position adjustment**hadj: adjustment in dots.
    d2,hadjSame as d1 except the parameter is not saved to non-
    volatile memory.
    Notes:
    1.  x and y represents horizontal and vertical co-ordinate values.
    2.  hm and vm stand for horizontal and vertical multipliers.
    3.  rot is the rotation direction, its value is from 0 to 3.
    4.  nr is either N for normal printing or R for reverse printing.
    5.  string is bracket by double quote marks, e.g. “text”.
    6.  ** Commands will cause the printer to save the parameters to non-volatile memory.
    7.  ZS takes effect only if flash memory board is installed. 
    						
    							Users Guide 36
    PRINTER DRIVER
    The bundled printer driver is used for applications under Windows 95/98/2000 and Windows NT.
    You may run any popular software application, such as MS-Word, as long as they are for Windows
    and printing the contents to the printer through the designated driver.
    Before starting installation you should:
    ♦ Check the contents of the driver to ensure it is complete.
    ♦ Make a backup copy of the driver.
    ♦ Read the README.TXT file for installation guide and change notices.
    Under the root directory of the floppy there are some sub-directories
    - WIN98
    - WIN95
    - NT40
    - WIN2000
    Select the proper directory for installation according to your operating system.
    Driver Installation
    ♦ Windows needs to be running.
    ♦ Insert the appropriate printer driver diskette into the floppy disk drive.
    1. Click the “Start” button.
    2. Select “Settings”, then “Printers”
    3. Double click the “Add Printer” icon.
    4. At the Add Printer Wizard, Click “Next”.
    5. Specify the “Network” or “Local” button and click the “Next” button.
    6. Select “Installation from Floppy Disk” or Have Disk.
    7. Enter the floppy drive and path.
    A:\WIN95 A:\NT40
    A:\WIN98 A:\WIN2000
    8. Select the printer name to be installed on the  “List of Printers”, window.  Click “Next”.
    9. Select the communication port for the label printer. For parallel port, select “LPT1:”,
    “LPT2:” or “LPT3”, for serial port select “COM1:” or “COM2:”., Click Next. 
    						
    							Users Guide 37
    10. You may wish to change the Printer Name to be more descriptive.  Also select this
    printer as the Default printer.  Click Next.
    11. Select whether you want a test page to be printed, then click on Finish.
    12. After the related files have been copied to your system, the procedure is complete.
     
    Notes:
    1. If you are just updating your driver, make sure to delete the previous version first.
    2. If you install new bar code application software like BarTender, LabelView or CodeSoft, the
    driver should be activated and set as the current printer driver. 
    						
    							Users Guide 38
    How to Use the Driver
    After the driver is installed, you can open the Printers dialogue box and make parameter settings:
    Windows 95/98/2000/NT4.0 - Start ➩ Settings ➩ Printers ➩ Printer Name ➩ Properties
    Parameter setting:
    After entering the Selected Printer you can change the parameters to meet your configuration and
    needs.  The following Format is from Windows 98. 
    						
    							Users Guide 39
    Details Tab
    Print to the following port
    This allows you to select the IO port to link with the printer. The port may be one of
    parallel (LPT), serial (COM), network port or file.
    If the communication port is the serial port (COM1: or COM2:), check the baud rate and
    flow control as they must be consistent between host and printer.  The printer’s baud rate
    is printed on the following the self-test page.  The factory default baud rate is 9600.
    Print using the following driver
    This must match the printer that is attached  (for the FM402DT, FM402TT or FM403TT)
    when using the label printer. 
    						