    Have a look at the manual Anaheim Brushless DC MDC150012301 Brushless DC Controller Users Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 523 Anaheim manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							April 2012 L010364
    MDC150-012301
    12V, 30A Brushless Controller 
    User’s Guide
    910 East Orangefair Lane, Anaheim, CA 92801
    e-mail: [email protected](714) 992-6990  fax: (714) 992-0471
    website: www.anaheimautomation.com
    ANAHEIM AUTOMATION 
    						
    							April 2012 L010364
    General Description
    The MDC150-012301 driver is designed to drive DC brushless motors at current of up to 30A (peak) and 
    12V.  Using hall sensor feedback, a constant velocity mode can be selected.  The driver is protected against 
    over current (cycle-by-cycle or latched), hall sensor error and under voltage.  When an error occurs, a 
    fault light is turned on to notify the user.  Included on the driver is an internal potentiometer to control the 
    maximum phase current allowed into the motor and an internal potentiometer to control the speed of the 
    motor.  An optional external potentiometer (10K) or external voltage (1-4VDC) can be used to control the 
    speed as well.  The direction of the motor can be preset by the direction control input.  Other inputs to 
    the drive include a run/stop and a motor freewheel input.  When using the run/stop input, there are three 
    ramp up profi les from standstill to select from.  The run/stop input overrides all other inputs into the driver. 
    Fault Protection
    Over current protection can be provided by means of a over current latch function by setting the ‘FLT 
    LATCH’ dip switch on.  If a motor current level exceeding the current limit set by the internal or exter-
    nal current limit potentiometer is produced, and over current latch is activated, shutting off the output.  
    When a fault is detected, the driver turns off the motor current, the red FAULT LED alerts the user a 
    fault occurred and the Fault Output (TB3 - Pin 5) goes low.  The Fault Output is disabled, logic ‘1’ out-
    put, when the ‘FLT LATCH’ dip switch is in the off position and disabled.  This Fault protection alerts the 
    user of the following conditions.
    1.  Invalid Sensor Input Code
    2.  Over Current.  The driver is equipped with cycle-by-cycle current limiting or over current    
       latch.
    3.  Undervoltage Lockout activation at 9.1VDC for the input voltage and 4.5VDC for the    
        Hall Sensor voltage.
    MDC150-012301 Driver Features
    • Maximum Current Limit Setting from 10.0-30.0 Amps (peak)
    • Internal or External Potentiometer Speed Control
    • 2-Quadrant Operation
    • Hall Sensor Feedback
    • Constant Velocity Mode
    • Short Circuit Protection
    • Requires 12VDC
    • Speed Out     • TTL-CMOS Compatible Inputs
    • Fault Out           • Compact Size (5.25”x3.06”x1.65”)
    • Brake, Disable and Direction Inputs   • Dual Mounting Option
    • Selectable Ramp Up/Down      • Detachable, Screw Type Terminal Block
    Ordering Information
    Part # Description
    MDC150-012301 Featured BLDC driver 30A, 12V
    CBL-AA5420 Cable, 3 Pins 12in. Long, For External Pot 
    						
    							April 2012 L010364
    Specifi cations
    Control Inputs: (TB3, Pins 2-4)
    TTL-CMOS Compatible
    Logic “0” = 0-0.8VDC
    Logic “1” = OPEN
    All three inputs (run/stop, freewheel and direction) are pulled up to through 20k ohm resistors.
    Freewheel: (TB3, Pin 3)
    Logic “1” (open) - Motor is Enabled
    Logic “0” - Motor is de-energized and will coast
    Direction Control: (TB3, Pin 2)
    Logic “1” (open) - Clockwise
    Logic “0” - Counterclockwise
    Run/Stop: (TB3, Pin 4)
    Logic “1” (open) - Motor will not run and if running will come to a hard stop
    Logic “0” - Motor will run and will accelerate according to ramp dip switch setting
    Fault Output: (TB3, Pin 5)
    Logic “1” (5V out) - Status good, normal operation.
    Logic “0” - One of the three fault conditions listed in the ‘Fault Protection’ section has occurred.
    Speed Output: (TB3, Pin 1)
    A 5V signal pulse out is available at a rate of 4 pulses for 1 revolution of an 8-pole motor, 3 pulses for 1 
    revolution of a 6-pole motor, and 2 pulses for 1 revolution of a 4-pole motor.
    8-pole motor RPM = 15 * PG OUT (in Hz)
    6-pole motor RPM = 20 * PG OUT (in Hz)
    4-pole motor RPM = 30 * PG OUT (in Hz)
    Output Current Rating:
    Adjustable 10.0 - 30.0 amperes per phase maximum operating peak current
      (5.0 - 15.0 amperes per phase maximum operating continuous current)
    Power Requirements: (TB2, Pins 1 and 2)
    10VDC (min) - 15VDC (max)
    Operating Temperature
    Heat Sink: 0°-70° C
    Hall Sensor Power Output:
    6.25V @30mA maximum.  Typical current draw from hall sensors in 20mA.
    All three Hall Sensor inputs are pulled up through 20K ohm resistors.
    The external speed control potentiometer must be 10K Ohms.
    Heating Considerations
    The temperature of the heat sink should never be allowed to rise above 70° C.  If necessary, mount the unit 
    to an additional heat sink or air should be blown across the heat sink to maintain suitable temperatures. 
    						
    							April 2012 L010364
    Commutation Sequence
    + = Top Transistor ON, Bottom Transistor OFF, Current fl ows into this wire
    - = Top Transistor OFF,  Bottom Transistor ON, Current fl ows out of this wire
    Z = Top Transistor OFF, Bottom Transistor OFF,  No current into or out of this wire (High Impedance)
    Motor Connection
    Refer to the hookup diagram for typical driver applications.  When connecting a motor for the fi rst time, 
    connect the hall sensor wires (5 of them) to the driver.  DO NOT CONNECT THE PHASES YET.  Turn 
    on power and rotate the motor by hand.  If the RED FAULT LED comes on, the hall phases are incor-
    rectly wired.  If the RED FAULT LED does not come on then the hall wires are connected correctly.  
    Power the unit down and proceed to connect the motor phases.  If the motor does not run or runs 
    erratically, power down and check the speed potentiometer and make sure the phases are connected 
    correctly.  There are six different ways to connect the phase wires, and normally only two will allow the 
    motor to rotate, but only one is correct.  If the direction of the motor is changed and the no-load current 
    of the motor is approximately the same and the motor runs smoothly in both directions then the phase 
    wires are correct.
    The wiring of the motor phases should be separated from the hall and input connections to not allow a 
    possible source of interference.
    Step
    123456
    Phase A + Z - - Z +
    Phase B Z + + Z - -
    Phase C - - Z + + Z
    Hall A110001
    Hall B011100
    Hall C000111
    Step
    123456
    Phase A - Z + + Z -
    Phase B Z - - Z + +
    Phase C + + Z - - Z
    Hall A110001
    Hall B011100
    Hall C000111
    Step
    123456
    Phase A + Z - - Z +
    Phase B Z + + Z - -
    Phase C - - Z + + Z
    Hall A111000
    Hall B011100
    Hall C001110
    Step
    123456
    Phase A - Z + + Z -
    Phase B Z - - Z + +
    Phase C + + Z - - Z
    Hall A 1 1 1 0 0 0
    Hall B 0 1 1 1 0 0
    Hall C 0 0 1 1 1 0
    120° Hall Spacing Sequence Forward120° Hall Spacing Sequence Reverse
    60° Hall Spacing Sequence Forward
    60° Hall Spacing Sequence Reverse 
    						
    							April 2012 L010364
    Dip Switch and Jumper Settings Terminal and Dip Switch Descriptions
    TB1: Motor Hall Terminals
    Pin # Description
    1 Hall Sensor Power
    2 Hall Sensor A
    3 Hall Sensor B
    4 Hall Sensor C
    5 Hall Sensor Ground
    Function SW1 SW2 SW3 SW4 SW5 JP2
    Constant Speed Mode (Closed Looped) Off --- --- --- --- ---
    Voltage Controlled Speed Mode (Open Loop) On --- --- --- --- ---
    Over Current Latching --- On --- --- --- ---
    Over Current Cycle by Cycle --- Off --- --- --- ---
    Ramp Profi le 1 (4 Sec) --- --- Off Off --- ---
    Ramp Profi le 2 (2 Sec) --- --- Off On --- ---
    Ramp Profi le 3 (1 Sec) --- --- On Off --- ---
    Ramp Profi le 4 (500mSec) --- --- On On --- ---
    60° Hall Sensor Spacing --- --- --- --- Off ---
    120° Hall Sensor Spacing --- --- --- --- On ---
    Internal Speed Control (JP2) --- --- --- --- --- 1-2
    External Speed Control (JP2) --- --- --- --- --- 2-3
    Standard Product (Ready to Ship) Off Off Off Off On 1-2
    Pin # Description
    1 Power In (10-15VDC)
    2 Ground
    3 Phase C
    4 Phase B
    5 Phase A
    Pin # Description
    1 PG OUT
    2 Direction
    3 Freewheel
    q Run/Stop
    5 Fault Out
    6 GND
    TB2: Power and Motor 
    Phase Terminals
    TB3: Control Inputs and 
    Outputs
    P1: 10K External Pot
    Pin # Description
    1 +4.0V (Pot Top)
    2 Pot Wiper
    3 +1.0V (Pot Bottom)
    SW: Dip Switch
    SW # Description
    1 O/C LOOP
    2 FLT LATCH
    3 RAMP 1
    4 RAMP 2
    5 60/120 
    						
    							April 2012 L010364
    Motor Freewheel
    The motor freewheel feature allows the de-energizing of the motor phases.  A high (open) input at this input 
    causes the motor to run at the given speed, while a low at this input causes the motor to coast to a stop.
    Motor Run/Stop
    The motor run/stop feature allows the stopping of a motor by shorting out the bottom drives of the three 
    phases.  A low at this input allows the motor to run,  while a high (open) input does not allow motor opera-
    tion and if operating causes rapid deceleration.
    Motor Direction
    The motor direction feature allows the changing of the rotation of the motor.  This input should not be 
    changed while motion is in progress.  A high (open) input causes the motor to turn in the CW direction, 
    while a low at this input causes the motor to turn in the CCW direction.
    Speed Adjust Setting
    There are two ways to set the speed on this drive.  One is to use the on board potentiometer.  The other 
    is to use an external 10K potentiometer.   To use the on board potentiometer, set jumper JP2 to position 
    1-2 (default).  To use the external 10K potentiometer or external 1V to 4V voltage speed setting, remove 
    cover and set jumper JP2 to position 2-3.  A voltage of 1V-4V to control the speed of the motor can be 
    tied to the Pot Wiper connection of P1 with 0V tied to pin 6 of TB3 (GND). 
    The mating connector for the external 10K potentiometer is Molex part number 3-640440-3.
    Speed Output
    The PG OUT terminal (TB3 - pin 1) is used to determine the speed of the motor shaft.  A 5V signal pulse 
    out is shown at a rate of 4 pulses for 1 revolution of an 8-pole motor, 3 pulse for 1 revolution of a 6-pole 
    motor, and 2 pulses for 1 revolution of a 4-pole motor.
    Fault Output
    The Fault Output is only active when the Fault Latch is enabled, setting the ‘FLT LATCH’ dip switch on.  
    The TTL level Fault Output indicates an over current or failure in the motor/driver operation.  The Fault 
    Output is normally at a TTL logic level 1.  If a fault occurs, the Fault Output will go to a TTL logic level 0.
    # Poles RPM
    8 15 * PG OUT (in Hz)
    6 20 * PG OUT (in Hz)
    4 30 * PG OUT (in Hz) 
    						
    							April 2012 L010364
    Typical Hookup Drawing
    Dimensions 
    						
    							April 2012 L010364
    ANAHEIM AUTOMATION
    COPYRIGHT 
    Copyright 2007 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, 
    transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by 
    any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior 
    written permission of Anaheim Automation, 910 E. Orangefair Lane, Anaheim, CA 92801. 
    DISCLAIMER
    Though every effort has been made to supply complete and accurate information in this manual, the 
    contents are subject to change without notice or obligation to inform the buyer. In no event will Anaheim 
    Automation be liable for direct, indirect, special, incidental, or consequential damages arising out 
    of the use or inability to use the product or documentation.  
    Anaheim Automation’s general policy does not recommend the use of its’ products in life support applications 
    wherein a failure or malfunction of the product may directly threaten life or injury.  Per Anaheim Automation’s 
    Terms and Conditions, the user of Anaheim Automation products in life support applications assumes all 
    risks of such use and indemnifi es Anaheim Automation against all damages.
    LIMITED WARRANTY
    All Anaheim Automation products are warranted against defects in workmanship, materials and construction, 
    when used under Normal Operating Conditions and when used in accordance with specifi cations.  This 
    warranty shall be in effect for a period of twelve months from the date of purchase or eighteen months 
    from the date of manufacture, whichever comes fi rst. Warranty provisions may be voided if products 
    are subjected to physical modifi cations, damage, abuse, or misuse.
    Anaheim Automation will repair or replace at its’ option, any product which has been found to be defective 
    and is within the warranty period, provided that the item is shipped freight prepaid, with previous authorization 
    (RMA#) to Anaheim Automation’s plant in Anaheim, California. 
    TECHNICAL SUPPORT
    If you should require technical support or if you have problems using any of the equipment covered by this 
    manual, please read the manual completely to see if it will answer the questions you have. If you need 
    assistance beyond what this manual can provide, contact your Local Distributor where you purchased the 
    unit, or contact the factory direct. 
    						