Page 21
20 Transmit Enter the command [ACO] to go into the converse mode. Type text from the keyboard, then hit the enter key at the end of the text. NNNNNNNN [CR] NNNNNNNN ASCII character [CR] Carriage Return Note: Maximum data length is 2046 bytes per packet. To send binary data, add [FE] (hexadecimal) to a header and footer with the data. FE BBBBBBBBBBBBBBBB FE BBBBBBBBBBBBBBB Binary data FE ID...
Page 22
21 Digital Image Communication Note: An optional memory module is required to use this function. Receive W hen valid digital image data is received, it will be decoded and output as a video image from the VIDEO OUT connector. If received data is missing during a transmission, that portion will be displayed as invalid (like noise). Transmit W hen pin - 4 of the microphone connector is grounded, the ARD9800 starts sending the image. Note: W hen the Video Through Function is...
Page 23
22 Specifications OFDM Band W idth: 300 Hz ~ 2.5 KHz, 36 carrier Symbol Rate 20 mS (50 Baud) Guard Interval 4 mS Tone Space 62.5 Hz Modulation Method Individual Tone Modulation Method 36 carrier: DQPSK(3.6K) Auto Frequency Offset +/- 125 Hz Error Correction Data: Reed Solomon + Vitabi Decoder Voice: Golay + Hamming Header 1 second, 3 tone + BPSK training pattern for synchronization Digital Audio AMBE ® 2020 Coder/Decoder Mode Selection Receive:...
Page 24
23 Control Commands Interfacing to a PC Using the supplied PC interface cable, connect between the COM connector at the rear panel (marked as [10101] ) to the serial port of a PC. NOTE: Be sure your PC’s serial port is active. Check for correct hardware and software settings! Below are the pin assignments of the COM connector of the ARD9800. ARD9800 COM connector Serial connector of a PC (D-Sub 9 – pin) Pin #...
Page 25
24 Command Format Run a terminal software program, and then turn the power of the ARD9800 on. The following message should appear on the PC screen: cmd> This indicates the ARD9800 is ready to accept commands from the PC. Each command consists of three (3) alphabetical characters. cmd>CCC_NN [CR] CCC: Command (Must be a capital letter) _: Space NN: Parameter [CR]: Carriage Return Entering a command without a parameter will display the current parameter...
Page 26
25 Command List Command Function AAQ Send VIDEO In signal to VIDEO OUT (to a monitor screen) Capture image into memory of the ARD9800 ACO Enter the Converse mode ADC List the current commands ADS Display current settings AFC Activate AFC (Automatic Frequency control) function AHL Set the duration of the synchronization header ALF Add the LF (Line Feed) code at the end of the CR code ARA Monitor both digital/analog voice signal or monitor digital voice only AT T Select output level for...
Page 27
26 Command details AAQ Function Send VIDEO In signal to the VIDEO OUT (to the monitor screen) Capture image into memory of the ARD9800 Default None Format AAQ {0 / 1} [CR] Parameter 1: Send VIDEO In signal to a VIDEO OUT (to the monitor screen) 0: Capture image into memory of the ARD9800 Details W hile AVT command is OFF, [AAQ 0] will be accepted. Entering AAQ[CR] will respond with the current status. AAQ ON --- Video signal is passed to the VIDEO OUT port AAQ OFF ----...
Page 28
27 ADC Function List the current commands Default None Format ADC [CR] Parameter None Details Lists the current commands Example ADC [CR] ADS Function Display current settings Default Headerlen : 1.00 AFC = ON Analog : ON Format ADS [CR] Parameter None Details Displays the current parameter settings Example ADS [CR] AFC Function Activate AFC (Automatic Frequency control) function Default On Format AFC {ON/OFF} [CR] Parameter ON: Activates the AFC function OFF:...
Page 29
28 AHL Function Set the duration of the synchronization header Default 100 (1 second) Format AHL {050 – 198} [CR] Parameter 050 – 198 (0.02 incremental) Details Sets the duration of the synchronization header {100} represents 1.00 second . Example AFC_146 [CR]
Page 30
29 AT T Function Selects the output level to the radio equipment Default ON Format ATT_ {ON/OFF} [CR] Parameter ON : Lower level OFF : Higher level Details Selects the output level to the radio equipment Refer to Level Adjustment at page XX for details Example ATT_ON [CR] AT X Function Send digital image Default None Format ATX [CR] Parameter None Details An image must be captured and stored into memory before it can be sent. Note: Optional memory module MUST be...