Hitachi Cp X2510n Projector Technical Manual
Here you can view all the pages of manual Hitachi Cp X2510n Projector Technical Manual. The Hitachi manuals for Projector are available online for free. You can easily download all the documents as PDF.
Page 21
21 NamesOperation Type Header Command Data CRC Action TypeSetting Code H SIZE GetBE EF0306 00 B5 82 02 0002 21 00 00 Increment BE EF0306 00 D3 82 04 0002 21 00 00 Decrement BE EF0306 00 02 8305 0002 21 00 00 H SIZE Reset ExecuteBE EF0306 00 68 D2 06 0004 70 00 00 AUTO ADJUST EXECUTE Execute BE EF0306 00 91 D0 06 000A 20 00 00 PROGRESSIVE SetOFF BE EF0306 00 4A 72 01 0007 22 00 00 TV BE EF0306 00 DA 73 01 0007 22 01 00 FILM BE EF0306 00 2A 73 01 0007 22 02...
Page 22
22 (continued on next page) RS-232C Communication / Network command table (continued) NamesOperation Type Header Command Data CRC Action TypeSetting Code FRAME LOCK – COMPUTER IN1 Set OFF BE EF0306 00 3B C2 01 0050 30 00 00 ON BE EF0306 00 AB C3 01 0050 30 01 00 Get BE EF0306 00 08 C2 02 0050 30 00 00 FRAME LOCK – COMPUTER IN2 Set OFF BE EF0306 00 0B C3 01 0054 30 00 00 ON BE EF0306 00 9B C2 01 0054 30 01 00 Get BE EF0306 00 38 C3 02 0054 30 00 00 AUTO KEYSTONE V...
Page 23
23 (continued on next page) RS-232C Communication / Network command table (continued) Names Operation Type Header Command Data CRC Action TypeSetting Code VOLUME - COMPUTER IN2 Get BE EF0306 00 FD CD 02 0064 20 00 00 Increment BE EF0306 00 9B CD 04 0064 20 00 00 Decrement BE EF0306 00 4A CC 05 0064 20 00 00 VOLUME - COMPONENT Get BE EF0306 00 01 CC 02 0065 20 00 00 Increment BE EF0306 00 67 CC 04 0065 20 00 00 Decrement BE EF0306 00 B6 CD 05 0065 20 00 00 VOLUME -...
Page 24
24 (continued on next page) RS-232C Communication / Network command table (continued) Names Operation Type Header Command Data CRC Action TypeSetting Code AUDIO OUT STANDBY SetAUDIO IN1 BE EF0306 00 7A DF 01 003F 20 01 00 AUDIO IN2 BE EF0306 00 8A DF 01 003F 20 02 00 AUDIO IN3 BE EF0306 00 1A DE 01 003F 20 03 00 OFF BE EF0306 00 EA DE 01 003F 20 00 00 Get BE EF0306 00 D9 DE 02 003F 20 00 00 LANGUAGE * SetENGLISH BE EF0306 00 F7 D3 01 0005 30 00 00 FRANÇAIS BE EF0306...
Page 25
25 (continued on next page) RS-232C Communication / Network command table (continued) Names Operation Type Header Command Data CRC Action TypeSetting Code BLANK SetMyScreen BE EF0306 00 FB CA 01 0000 30 20 00 ORIGINAL BE EF0306 00 FB E2 01 0000 30 40 00 BLUE BE EF0306 00 CB D3 01 0000 30 03 00 WHITE BE EF0306 00 6B D0 01 0000 30 05 00 BLACK BE EF0306 00 9B D0 01 0000 30 06 00 Get BE EF0306 00 08 D3 02 0000 30 00 00 BLANK On/Off SetOFF BE EF0306 00 FB D8 01 0020 30...
Page 26
26 RS-232C Communication / Network command table (continued) Names Operation Type Header Command Data CRC Action TypeSetting Code AUTO OFF GetBE EF0306 00 08 8602 0010 31 00 00 Increment BE EF0306 00 6E 86 04 0010 31 00 00 Decrement BE EF0306 00 BF 87 05 0010 31 00 00 LAMP TIME GetBE EF0306 00 C2 FF 02 0090 10 00 00 LAMP TIME Reset ExecuteBE EF0306 00 58 DC 06 0030 70 00 00 FILTER TIME GetBE EF0306 00 C2 F0 02 00A0 10 00 00 FILTER TIME Reset ExecuteBE EF0306 00 98...
Page 27
27 Names Operation Type Header Command Data CRC Action TypeSetting Code REMOTE FREQ. HIGH Set OFF BE EF0306 00 03 3C 01 0031 2600 00 ON BE EF0306 00 93 3D 01 0031 2601 00 Get BE EF0306 00 30 3C 02 0031 2600 00 MY IMAGE SetOFF BE EF0306 00 3A C3 01 0000 3500 00 IMAGE-1 BE EF0306 00 AA C2 01 0000 3501 00 IMAGE-2 BE EF0306 00 5A C2 01 0000 3502 00 IMAGE-3 BE EF0306 00 CA C3 01 0000 3503 00 IMAGE-4 BE EF0306 00 FA C1 01 0000 3504 00 Get BE EF0306 00 09 C3 02 0000 3500 00 MY IMAGE IMAGE-1...
Page 28
28 PJLink command PJLink command CommandsControl Description Parameter or Response POWR Power Contorol 0 = Standby 1 = Power On POWR ? Power Status inquiry 0 = Standby 1 = Power On 2 = Cool Down INPT Input Source selection 11 = COMPUTER IN 1 12 = COMPUTER IN 2 21 = COMPONENT 22 = S-VIDEO 23 = VIDEO INPT ? Input Source inquiry 11 = COMPUTER IN 1 12 = COMPUTER IN 2 21 = COMPONENT 22 = S-VIDEO 23 = VIDEO AVMT AV Mute10 = BLANK off 11 = BLANK on 20 = Mute off 21 = Mute on 30 = AV Mute off 31 = AV Mute on...
Page 29
29 PJLink command (continued) CommandsControl Description Parameter or Response ERST ? Error Status inquiry 1st byte: Refers to Fan error; one of 0 to 2 2nd byte: Refers to Lamp error; one of 0 to 2 3rd byte: Refers to Temptrature error; one of 0 to 2 4th byte: Refers to Cover error; one of 0 to 2 5th byte: Refers to Filter error; one of 0 to 2 6th byte: Refers to Other error; one of 0 to 2 The mearning of 0 to 2 is as given below 0 = Error is not detected; 1 = Warning; 2 = Error LAMP ? Lamp Status...