    							Preinstallation Information2–5
    Hitachi Storage Navigator Modular 2 User’s Guide
    Sun Solaris operating systems
    Table 2-4 lists the Navigator 2 requirements for management consoles 
    running a supported Sun Solaris operating system. For information about 
    supported Sun Solaris hosts and their requirements, see:
    • The Hitachi AMS 2100/2300 Getting Started Guide (MK-98DF8152EN) 
    • The Hitachi AMS 2500 Getting Started Guide (MK-97DF8032EN)
    • The interoperability matrix at http://www.hds.com/products/
    interoperability/
     
    Red Hat Linux operating systems
    Table 2-5 on page 2-6 lists the Navigator 2 requirements for management 
    consoles running a supported Red Hat Linux operating system. For 
    information about supported Red Hat Linux hosts and their requirements, 
    see:
    • The Hitachi AMS 2100/2300 Getting Started Guide (MK-98DF8152EN) 
    • The Hitachi AMS 2500 Getting Started Guide (MK-97DF8032EN)
    • The interoperability matrix at http://www.hds.com/products/
    interoperability/
    Table 2-4:  Requirements for Management Consoles 
    Running Sun Solaris 
    ItemRequirement
    Operating systems • Solaris 8 (SPARC)
    •Solaris 9 (SPARC)
    • Solaris 10 (SPARC)
    • Solaris 10 (x86)
    • Solaris 10 (x64)
    Processor • SPARC: 1 GHz (2 GHz or faster recommended)
    • Solaris 10 (x64): 1.8 GHz (2 GHz or faster 
    recommended)
    Random Access Memory 1 GB (2 GB or more recommended)
    Available disk space 1 GB or more
    Video resolution 800 x 600 dots per inch (1024 x 768 or later 
    recommended), 256 colors or more
    Browser (with pop-up 
    blockers disabled)• Mozilla v1.7
    •Firefox 2
    JRE JRE v1.6.0_15 
    						
    							2–6Preinstallation Information
    Hitachi Storage Navigator Modular 2 User’s Guide
    Network requirements
    The management console can be used with the items in Table 2-6.
    Setting of Linux kernel parameters
    When you install Hitachi Storage Navigator Modular 2 to Linux, set the Linux 
    kernel parameters. Otherwise, the installer ends without installing the 
    hsoftware. The only exception is if Navigator 2 has already been installed 
    and used in a Hitachi Storage Command Suite Common Component 
    environment. In this case, you do not need to set the Linux kernel 
    parameters. 
    To set the Linux kernel parameters
    1. Back up the kernel parameters setting file (/etc/sysctl.conf and /etc/
    security/limits.conf).
    Table 2-5:  Requirements for Management Consoles 
    Running Red Hat Linux
    ItemRequirement
    Operating systems • Red Hat Enterprise Linux AS 4.0 update 1 
    • Red Hat Enterprise Linux AS 4.0 update 5
    • Red Hat Enterprise Linux 4.0 update 1
    • Red Hat Enterprise Linux 4.0 update 5
    • Red Hat Enterprise Linux 5.0 update 3
    • Red Hat Enterprise Linux 5.0 update 4
    Processor 1 GHz (2 GHz or faster recommended)
    Random Access Memory 1 GB (2 GB or more recommended)
    Available disk space 1 GB or more
    Video resolution 800 x 600 dots per inch (1024 x 768 or later 
    recommended), 256 colors or more
    Browser (with pop-up 
    blockers disabled)Mozilla v1.7
    JRE JRE v1.6.0_15
    Table 2-6:  Network Requirements
    ItemDescription
    Network Interface Card 
    (NIC)For supported NICs, see the interoperability matrix at 
    http://www.hds.com/products/interoperability/.
    Ethernet cable The management ports support Auto-MDI/MDIX 
    technology, allowing you to use either standard (straight-
    through) or crossover Ethernet cables.
    Switch or hub • For Fibre Channel networks, use a Fibre Channel 
    switch or hub.
    • For iSCSI networks, use an iSCSI switch or hub. 
    						
    							Preinstallation Information2–7
    Hitachi Storage Navigator Modular 2 User’s Guide
    2. Ascertain the IP address of the management console (for example, using 
    ipconfig in a DOS environement). Then change its IP address to 
    192.168.0.
    x where x is a number from 1 to 254, excluding 16 and 17. 
    Write this IP address on a piece of paper. You will be prompted for it 
    during the Storage Navigator Modular 2 installation procedure.
    3. Disable popup blockers in your Web browser. We also recommend that 
    you disable anti-virus and proxy settings on the management console 
    when installing the Storage Navigator Modular 2 software.
    4. To log in to Storage Navigator Modular 2 with a Red Hat Enterprise Linux 
    (RHEL) operating system, modify the kernel settings as follows:
    • SHMMAX parameter. This parameter defines the maximum size, in 
    bytes, of a single shared memory segment that a Linux process 
    can allocate in its virtual address space. If the RHEL default 
    parameter is larger than both the SNM2 and Database values, you 
    do not need to change it.
    • SHMALL parameter. This parameter sets the total amount of 
    shared memory pages that can be used system wide. For SNM2, 
    this value must equal the sum of the default value, SNM2, and 
    Database values.
    • Other parameters. The following parameters follow the same rule 
    as SHMALL and must be the higher of (RHEL current value + 
    value in Navigator 2 column) or the value from the Database 
    value.
    • kernel.shmmni
    • kernel.threads-max
    • kernel.msgmni
    • kernel.sem (second parameter)
    • kernel.sem (fourth parameter)
    •  fs.file-max nofile nproc
    Table 2-7 details recommended values for Linux kernel parameters.
    Table 2-7:  Linux kernel parameters
    Parameter 
    NameStandard 
    RHEL 5.xSample 
    Customer 
    ValuesStorage 
    Navigator 
    Modular 2SNM2 
    DatabaseRequired 
    New Value
    kernel.shmmax 4294967295 4294967295 11542528 20000000
    04294967295
    kernel.shmall 268435456 268435456 22418432 22418432 22418432
    kernel.shmmni 40964096 0 2000 2000
    kernel.threads-
    max65536
    122876
    184 574 123060
    kernel.msgmni 32 32 32 32 64
    kernel.sem  
    (Second 
    parameters)32000 32000 80 7200 32080 
    						
    							2–8Preinstallation Information
    Hitachi Storage Navigator Modular 2 User’s Guide
    5. Open the kernel parameters setting file (/etc/sysctl.conf) with a 
    standard text editor and change referring to the following.
    The parameters are specified using the form, which is [name of 
    parameter]=[value]. Four values separated by space are specified in 
    kernel.sem.
    Then, the parameter must not exceed the maximum value that OS 
    specifies.
    The value can be checked by the following command.
    cat /proc/sys/kernel/shmmax (Case: Check value of 
    kernel.shmmax)
    The default physical management port IP addresses are set to:
    • Controller 0:192.168.0.16
    •  Controller 1: 192.168.0.17
    6. Reboot host.
    kernel.sem 
    (Fourth 
    parameters)128 128 9 1024 1024
    fs.file-max 205701 387230 53898 53898 441128
    nofile 0 0 572 1344 1344
    nproc 0 0 165 512 512
    Table 2-7:  Linux kernel parameters 
    						
    							Preinstallation Information2–9
    Hitachi Storage Navigator Modular 2 User’s Guide
    Collecting user-supplied items
    Before installing Navigator 2, be sure you have the following user-supplied 
    items.
    • Navigator 2 installation CDs or access to the Hitachi Data Systems Web 
    Portal:support.hds.com.
    • A PC that will act as the management console for managing the storage 
    system using Navigator 2. See Navigator 2 operating environment on 
    page 2-3.
    • The IP address of each management port on your AMS 2000 Family 
    storage system that will connect to the Navigator 2 management 
    console. Refer to the document for your AMS hardware.
    • The IP address of the management console. See Getting started (all 
    users) on page 3-2.
    • The port number used to access Navigator 2 from your browser. The 
    default port is 1099.
    • The password you will use to replace the default system account 
    password.
    • License keys required by each program product you want to use. See 
    Obtaining license keys on page 2-12.
    Installing Java runtime
    If the management console does not have the required version of JRE 
    installed, as indicated under Navigator 2 operating environment on page 2-
    3), use the procedures in the following sections to download and install it.
    Downloading and installing JRE
    You can download JRE from the following site and install it by following the 
    on-screen prompts:
    http://java.com/en/download/
    After installing JRE v6.0, refer to the appropriate section that follows to 
    complete the installation for the operating system running on the 
    management console.
    Clients running Microsoft Windows
    To install JRE if your management console runs Microsoft Windows
    1. Click the Windows Start menu, point to Settings, and click Control 
    Panel. The Windows Control Panel appears.
    2. In the Windows Control Panel, double-click Java Control Panel. The 
    Java Control Panel appears.
    3. Click the Java tab. The Java tab appears (see Figure 2-1 on page 2-10). 
    						
    							2–10Preinstallation Information
    Hitachi Storage Navigator Modular 2 User’s Guide
    Figure 2-1:  Java Tab
    4. Click View in the Java Applet Runtime Settings section. The Java 
    Runtime Settings dialog box appears.
    5. In the Java Runtime Parameters field, type -Xmx192m (see 
    Figure 2-2).
    Figure 2-2:  Java Runtime Settings Dialog Box
    6. Click OK to exit the Java Runtime Settings window. 
    						
    							Preinstallation Information2–11
    Hitachi Storage Navigator Modular 2 User’s Guide
    7. Click OK in the Java tab to close the Java Control Panel window.
    8. Close the Windows Control Panel.
    Clients running Solaris or Linux
    To install JRE if your management console runs a supported Solaris 
    or Linux operating system
    1. From an XWindows terminal, execute the /
    bin/jcontrol to run the Java Control Panel.
    2. Click View in the Java Applet Runtime Settings section. The Java 
    Runtime Settings window appears.
    3. In the Java Runtime Parameters field, type -Xmx192m.
    4. Click OK to exit the Java Runtime Settings window.
    5. Click OK in the Java tab to close the Java Control Panel window.
    Firewall considerations
    A firewalls main purpose is to block incoming unsolicited connection 
    attempts to your network. If the AMS 2000 Family storage system is used 
    within an environment that uses a firewall, there will be times when the 
    storage system’s outbound connections will need to traverse the firewall.
    The storage systems incoming indication ports are ephemeral, with the 
    system randomly selecting the first available open port that is not being 
    used by another Transmission Control Protocol (TCP) application. To permit 
    outbound connections from the storage system, you must either disable the 
    firewall or create or revise a source-based firewall rule (not a port-based 
    rule), so that items coming from the storage system are allowed to traverse 
    the firewall.
    Firewalls should be disabled when installing Navigator 2 (refer to the 
    documentation for your firewall). After the installation completes, you can 
    turn on your firewall.
    If you use Windows firewall, the Navigator 2 installer automatically registers 
    the Navigator 2 file and Command Suite Common Components as 
    exceptions to the firewall. Therefore, before you install Navigator 2, confirm 
    that no security problems exist.
    Anti-virus software considerations
    Anti-virus programs, except Microsoft Windows’ built-in firewall, must be 
    disabled before installing Navigator 2. In addition, Navigator 2 cannot 
    operate with firewalls that can terminate local host socket connections. As 
    a result, configure your anti-virus software to prevent socket connections 
    from being terminated at the local host (refer to the documentation for your 
    anti-virus software).
    NOTE:For outgoing traffic from the storage system’s management port, 
    there are no fixed port numbers (ports are ephemeral), so all ports should 
    be open for traffic from the storage system management port. 
    						
    							2–12Preinstallation Information
    Hitachi Storage Navigator Modular 2 User’s Guide
    Obtaining license keys
    Some Program Products require a license key before you can use them. 
    Typically, the license key required to activate these products is furnished 
    with the product. We recommend that you have these license keys available 
    before you activate the Program Products that require them. If you do not 
    have license keys for the Program Products, please contact technical 
    support.
    Reviewing technical guidelines
    The following sections cover technical guidelines to review before installing 
    Navigator 2 on a management console.
    Windows operating systems
    Installation prerequisites
    Before installing Navigator 2 on a management console running one of the 
    supported Microsoft Windows operating systems in Table 2-3 on page 2-4:
    • Log in to Windows as an Administrator or a member of the 
    Administrators group.
    • Disable power management through Windows to prevent the host from 
    entering suspension mode.
    Selecting a destination folder
    During the Navigation 2 installation, you are prompted to select a 
    destination folder. You can accept the default destination folder or select a 
    different destination folder.
    If you select a different destination folder, be sure the folder complies with 
    the following requirements:
    • The folder name should only contain the characters A to Z, a to z, 0 to 
    9, hash mark (#), plus sign (+), hyphen (-), period (.), at mark (@), 
    underscore (_), and the space character.
    • A space character cannot appear at the beginning or end of a folder 
    name.
    • The path name cannot contain any names reserved by the operating 
    system (for example, CON, AUX, NUL, PRN, CLOCK$, COM1 to COM9, 
    and LPT1 to LPT9).
    • The path to the destination folder cannot exceed 100 characters.
    • The path to the destination folder cannot be a route to a drive. 
    Otherwise, the installer displays the following error message during the 
    installation.
    • Do not specify a Uniform Naming Convention (UNC) path. 
    						
    							Preinstallation Information2–13
    Hitachi Storage Navigator Modular 2 User’s Guide
    Solaris and Linux operating systems
    Installation prerequisites
    Before installing Navigator 2 on a management console running one of the 
    supported Solaris and Linux operating systems in Table 2-3 on page 2-4:
    • Log on as a root user.
    •If /opt exists, the normal directory is required, not the symbolic link. 
    However, the file system can be mounted as a mount point.
    • For Solaris v10 (SPARC), apply the appropriate patch.
    •  Apply patch 120664-xx (where xx is 01 or later).
    •  Apply patch 127127-xx (where xx is 11 or later).
    •  Do not apply patches 127111-02 and 127111-03.
    • For Solaris v10 (x64), apply patch 120665-xx (where xx is 01 or later)
    • For Linux, set the kernel parameters described in the following 
    sections.
    Setting Linux kernel parameters
    To set the Linux kernel parameters:
    1. Back up the kernel parameters setting files /etc/sysctl.conf and  
    /etc/security/limits.conf.
    2. Open the kernel parameters setting file /etc/sysctl.conf with a text 
    editor and change the following settings. The parameters are specified 
    using the syntax [name of parameter]=[value]. Four values separated 
    by space are specified in kernel.sem. Your parameter settings must not 
    exceed the maximum value for the operating system. 
    The following example shows how to check whether the value is valid for 
    kernel.shmmax:
    cat /proc/sys/kernel/shmmax
    Table 2-8 provides recommended values and calculation methods for 
    each kernel type. 
    Table 2-8:  Kernel Type Recommended Values 
    Parameter Name
    Recommended Value
    Calculation Method
    Navigator 2Database
    kernel.shmmax 11542528 200000000 Maximum value in current and 
    two recommended values.
    kernel.shmall 22418432 22418432 Total value of current and 
    recommended values. 
    						
    							2–14Preinstallation Information
    Hitachi Storage Navigator Modular 2 User’s Guide
    Open the kernel parameters setting file /etc/security/limits.conf 
    with a text editor and change the following settings. The parameters are 
    specified using the syntax [domain] [type] [name of parameter] 
    [value]. Domains are specified for “*”. The types are specified for both 
    “soft” and “hard.” The soft value must not exceed the hard value. Then, 
    the parameter must not exceed the maximum value that the operating 
    system specifies.
     Table 2-9 shows the recommended values and calculation 
    methods for the kernel parameter types.
    3. Reboot the host.
    Setting Solaris v8 or Solaris v9 kernel parameters
    When installing Navigator 2 on a management console running Solaris v8 
    or Solaris v9, set the Solaris kernel parameters. 
    1. Back up the kernel parameters setting file /etc/system.
    kernel.shmmni 0 2000 The larger value of: 
    • The total value of current 
    and Navigator 2 
    recommended value. 
    •The database 
    recommended value. kernel.threads-max 184 574
    kernel.msgmni 32 32
    kernel.sem
    (Second parameters)80 7200
    kernel.sem
    (Forth parameters)9 1024
    fs.file-max 53898 53898
    Table 2-8:  Kernel Type Recommended Values (Continued)
    Parameter Name
    Recommended Value
    Calculation Method
    Navigator 2Database
    Table 2-9:  Kernel Parameter Recommended Values
    Parameter Name
    Recommended Value
    Calculation Method
    Navigator 2Database
    nofile 572 1344 The larger value of: 
    • The total value of current 
    and Navigator 2 
    recommended value. 
    •The database 
    recommended value. nproc 165 512 
    						