Page 151

8 - 33
UPC-E0 Addenda Separator
When this feature is On, there is a space between the data from the bar code and the data from the addenda.  When turned 
Off, there is no space.  Default = Off.
UPC-E0 Redundancy
If you are encountering errors when reading UPC-E0 bar codes, you may want to adjust the redundancy count.  Redun-
dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  
Note that the higher the redundancy count, the longer it will...

Page 152

8 - 34
EAN/JAN-13 Check Digit
This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.  
Default = On.
EAN/JAN-13 Addenda
This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data.  Default = Off for both 2 Digit and 5 Digit 
Addenda.
EAN/JAN-13 Addenda Required
When Required is scanned, the scanner will only read EAN/JAN-13 bar codes that have addenda.  Default = Not Required.
* Do not Convert  UPC-A
*  On
Off
2 Digit...

Page 153

8 - 35
EAN-13 Beginning with 2 Addenda Required
This setting programs the scanner to require a 2 digit addenda only on EAN-13 bar codes that begin with a “2.”  The follow-
ing settings can be programmed:
Require 2 Digit Addenda:  All EAN-13 bar codes that begin with a “2” must have a 2 digit addendum.  The EAN-13 bar 
code with the 2 digit addendum is then transmitted as a single, concatenated bar code.  If a 2 digit addendum is not found 
within the Addenda Timeout period, the EAN-13 bar code is...

Page 154

8 - 36
EAN-13 Beginning with 378/379 Addenda Required 
This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar 
codes that begin with a “378” or “379.”  The following settings can be programmed:
Require Addenda:  All EAN-13 bar codes that begin with a “378” or “379” must have a 2 digit addenda, a 5 digit addenda, 
or a combination of these addenda.  The EAN-13 bar code with the addenda is then transmitted as a single, concatenated 
bar code....

Page 155

8 - 37
EAN-13 Beginning with 434/439 Addenda Required 
This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar 
codes that begin with a “434” or “439.”  The following settings can be programmed:
Require Addenda:  All EAN-13 bar codes that begin with a “434” or “439” must have a 2 digit addenda, a 5 digit addenda, 
or a combination of these addenda.  The EAN-13 bar code with the addenda is then transmitted as a single, concatenated 
bar code....

Page 156

8 - 38
Default = Don’t Require 2 Digit Addenda.
EAN-13 Beginning with 978 Addenda Required
These settings program the scanner to require a 5 digit addenda only on EAN-13 bar codes that begin with “978.”  The fol-
lowing settings can be programmed:
Require 5 Digit Addenda:  All EAN-13 bar codes that begin with “978” must have a 5 digit addendum.  The EAN-13 bar 
code with the 5 digit addendum is then transmitted as a single, concatenated bar code.  If a 5 digit addendum is not found 
within the Addenda...

Page 157

8 - 39
Addenda Timeout
You can set a time during which the scanner looks for an addenda.  If an addenda is not found within this time period, the 
data can be either transmitted or discarded, based on the setting you are using for EAN/JAN-13 Addenda Required.  Set 
the length (in milliseconds) for this timeout by scanning the bar code below, then setting the timeout (from 0-65535 millisec-
onds) by scanning digits from the Programming Chart, then scanning Save.  Default = 100.
Note: The Addenda Timeout...

Page 158

8 - 40
Convert ISBN to 13-Digit
When translating EAN-13 codes to the ISBN format, you can convert the bar code to a 13 digit format by scanning the 
Convert to 13-Digit On bar code below.  Default = Convert to 13-Digit Off.
ISBN Reformat
In normal use, the first two or three digits of an EAN-13 bar code identify the country of origin.  The country prefixes are 
978 and 979.  To reformat ISBN codes so the country prefix is dropped out, scan the Reformat On bar code below.  
Default = Refor mat Off.
ISSN...

Page 159

8 - 41
ISSN Reformat
When Reformat On is scanned, EAN-13 977 Bookland symbols are translated into their equivalent 8-digit ISSN num-
ber format, with hyphens added to the output.  For example, 9770123456787 will be transmitted as 0123-456-0.  (You 
must first scan ISSN On (page 8-40) before scanning Reformat On.)  Default = Reformat Off.
EAN/JAN-8

EAN/JAN-8 On/Off
EAN/JAN-8 Check Digit
This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or...

Page 160

8 - 42
EAN/JAN-8 Addenda
This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data.  Default = Off for both 2 Digit and 5 Digit 
Addenda.
EAN/JAN-8 Addenda Required
When Required is scanned, the scanner will only read EAN/JAN-8 bar codes that have addenda.  Default = Not Required.
Addenda Timeout
You can set a time during which the scanner looks for an addenda.  If an addenda is not found within this time period, the 
data can be either transmitted or discarded, based on the setting you...