Page 21

21
DT92E OPERATING INDICATORS
Low Battery Indicator / Battery Replacement
The battery symbol will start 
to flash if the battery power is 
running low. From this point, 
there will be a minimum of 4 
weeks before the product will 
cease to function.
Batteries are accessed by 
unclipping the front cover at the 
bottom. Note battery polarity. 
Reverse process to refit front 
cover.
Use 2xLR6 (AA) alkaline 
batteries only. 
Immediately on power up, DT92E will try to communicate and synchronise with...

Page 22

22
DT92E ENERGY SAVING ECO FEATURE
The ECO button allows you to change to a lower, energy saving set temperature for 
a period of your choice, from 1 to 24 hours. This temperature is pre-set in the DT92E 
Installer Mode, but you can adjust this to any temperature you want when ECO mode 
has been activated. The default ECO temperature is 18°C.
At the end of the time period, the thermostat will return to its original set 
temperature.
Entering ECO Mode and Setting 
the Energy Saving Time Period
Press the...

Page 23

23
DT92E ENERGY SAVING ECO FEATURE
FINE TUNING YOUR  DT92E
Changing the DT92E Installer Parameters
The DT92E has a special Installer Mode where some features can be adjusted to suit 
your lifestyle or preferences – these are called Installer Parameters, and are listed in 
the table below, along with a description of the options that are possible.
Your installer should set this up for you to suit your application (see \
CONFIGURATION 
& SERVICE DATA section). However, you may wish to alter some of the...

Page 24

24
To Enter Installer Mode:
a. Hold the 
 button for 2 seconds until DT92E is in standby mode.
b. Hold 
 and  buttons for 3 seconds until the word ‘Inst’ appears on the 
display.
c.  Press the 
 button.
The first parameter is now ready to be changed.
To Select a Parameter:
Use the 
 and  buttons to move from one parameter 
to the next. Stop at the Parameter you wish to change.
To Change a Parameter:
Use the standby button to select the parameter value, then the 
 and  buttons to 
change the value....

Page 25

25
BDR91T Controls Layout
Automatic Operation
The BDR91T relay box simply switches the boiler 
on and off according to a wireless signal it receives 
from the ST9520C. It is mainly used when the boiler 
is installed  in a remote location where it may be 
difficult to run wires direct from the timer. The green 
light indicates the status of the relay output:
Green light on = relay on
Green light off = relay off
Temporary Manual Override
In normal operation it should not be necessary to 
interact with the...

Page 26

26
How do I set the time only, if the ST9520C clock is not correct?
Your ST9520C contains an accurate digital clock that is factory set. Should you ever 
need to change the time, just follow this procedure:
a. Move the slider to the DAY/TIME position.
b.  Keep pressing the green 
 button until the message ‘SET THE TIME’ is 
displayed. To change the time, press the   or  buttons until the correct 
time is shown. The message ‘IS TIME OK?’ will be displayed. Press the green  
button to confirm the time is...

Page 27

27
How reliable is 2-way RF communication?
The 2-way RF communication (also known as wireless communication) used by 
Honeywell is extremely robust and reliable. When installed correctly the Signal 
Strength test feature allows the Installer to locate the system components where 
mutual signal reception is strong. During communication, signals are sent several 
times to ensure receipt, and if any message is garbled, the error detection software 
recognises this and ensures the message is repeated again....

Page 28

28
Troubleshooting Guide
This is a quick guide to help you diagnose and cope with possible problems with 
your wireless control system. For further assistance, please contact your Installer.
SymptomPossible CauseRemedy
ST9520C has a blank LCD 
display No power to the 
heating system.Check that there is power to the 
heating system.
Fault in ST9520C
Call Installer
ST9520C indicates that 
Heating Zones are ON, but 
radiators are cold
Temperature controls 
are switched off or 
set too low.Check that the...

Page 29

29
SymptomPossible CauseRemedy
The ST9520C screen shows 
the message: Your boiler service 
is overdue and 
the boiler has 
been automatically 
switched off to 
ensure your safety.Arrange an immediate boiler 
service.
If set to do so, it may be 
possible to obtain limited use 
of the boiler by pressing any 
EXTRA HOUR button. Each 
button press will allow operation 
of the boiler for 1 hour at a time, 
and the screen will display the 
message ‘On 1h’.
After servicing your boiler, the 
Service Engineer /...

Page 30

30
SymptomPossible CauseRemedy
ST9520C shows the 
message ‘NO SIGNAL’ and 
a flashing radiator symbol 
 for one of the zones
DT92E shows a flashing RF 
symbol 
Your DT92E 
batteries are 
running low on 
power. Change the DT92E batteries 
(see page 21 for how to do this).
RF communication 
path between 
ST9520C and 
DT92E is blocked, 
possibly by a metal 
object. Check direct path between both 
products and re-position any 
objects that may be blocking 
the signal.
Relocate the DT92E, if possible.
ST9520C...