    							RTH2300/RTH221
    Programmable Thermostat
    Quick Installation Guide
    69-2448ES-03 
    						
    							69-2448ES—03 ii
    Quick Installation Guide
    Identify System Type
    This thermostat is compatible with the following systems:
    Gas, oil or electric furnace•	
    Central air conditioner•	
    Hot water system with or without pump•	
    Millivolt system•	
    Central heating and cooling system•	
    Heat pump without auxiliary/backup heat•	
    Do you need assistance?
    We are here to help.
    Call 1-800-468-1502.
    This thermostat cannot be used on heat pumps with auxiliary/backup heat or on multistage systems. 
    						
    							 1 69-2448ES—03
    RTH2300/RTH221
    1
    Turn Off Power to Heating/ 
    Cooling System
    M28097 
    						
    							69 -2448ES—03 2
    Quick Installation Guide
    Remove Old Thermostat2
    M28099
    Old thermostat
    Cover
    Remove old thermostat but leave wallplate with  wires attached.
    Do not remove wallplate yet
    MERCURY NOTICE  Do not put your old thermostat in the trash if it contains mercury in a sealed tube. Contact your local waste management authority for instructions regarding recycling and proper disposal. 
    						
    							 3 69-2448ES—03
    RTH2300/RTH221
    If any wires are not attached to your old thermostat or are attached to a terminal marked C or C1, they will not be connected to your new thermostat. Wrap the bare metal end of each of these wires with electrical tape, so it can-not touch and short other wires.
    Identify Wires3
    M29988
    Disconnect wires and remove the old wallplate only after all wires are labeled. Wrap the wires around a pencil to prevent them from falling though the wall opening.
    Do not use non-connected wires.
    Do not use C or C1 wires.
    Identify and label each wire.
    IGNORE WIRE COLORS:  Use terminal screw designations to identify wires. 
    						
    							69 -2448ES—03 4
    Quick Installation Guide
    Mount New Wallplate
    Loosen the locking screw at the bottom of the 1. thermostat. Note that the screw is captive and cannot be removed from the wallplate.
    Separate the thermostat from the wallplate as per 2. Figure 1.
    Position the wallplate against the wall and mark hole 3. positions with a pencil.  NOTE: Levelling is for esthetics only and will not affect the performance of the thermostat.
    Drill holes at the marked positions and insert supplied 4. wall anchors.
    Pass the wires through the large opening located at 5. the bottom center of the wallplate as per Figure 2.
    Secure the wallplate to the wall with supplied mounting 6. screws as per Figure 3.
    Connect the wires to the terminals.7. 
    4
    Figure 1Figure 2Figure 3
    M32154 
    						
    							 5 69-2448ES—03
    RTH2300/RTH221
    Connect Wires (typical wiring)
    Loosen the terminal screws using a screwdriver, insert 2. the wires, then tighten the screws.
    Push any excess wire back into the wall opening.3. 
    Labels don’t match?  If a wire does not match any terminal designation, see next page.
    5
    Match each labeled wire with the terminal having the 1. same letter.
    O/B       Y        RC         R        G          WM32155A
    REMOVE JUMPER
    IF YOU HA VE BOTH 
    R A ND RC WIRES 
    						
    							69 -2448ES—03 6
    Quick Installation Guide
    Connect Wires (alternate wiring)5
    If labeled wire does not match any terminal designation, see diagram below.
    M32169A
    REMOVE JUMPER BETWEEN R AND RC IF YOU HAVE 
    WIRES ON BOTH  R AND RC.
    DO NOT USE C, C1, OR X WIRE.  DO NOT USE B WIRE 
    IF YOU ALREADY HAVE 0 WIRE.  WRAP BARE END OF 
    WIRE WITH ELECTRICAL TAPE.
    PLACE A JUMPER (PIECE OF WIRE) BETWEEN Y AND 
    W IF YOU ARE USING A HEAT PUMP WITHOUT 
    AUXILIARY/BACKUP HEAT.
    1
    2
    3
    O/B       Y        RC         R         G          W
    2331
    1
    OR
    C1 X
    B OR
    B
    H OR
    Y1 M OR
    RH 4
    V OR
    F OR
    W1
    H
    1
    ORR 
    						
    							 7 69-2448ES—03
    RTH2300/RTH221
    Set jumper JP1, on the back of the thermostat, if you have connected a wire to the G terminal.
    Set Heating Fan Control6
    HGLeave the jumper in this factory-set position if you have a gas or oil furnace.
    HEPlace the jumper to this position if you have an electric furnace.
    Incorrect jumper setting: An incorrect setting is notice-able in a gas or oil heating system. When heating starts, you will initially feel cold air coming out of the vents as the fan is running before the furnace has enough time to heat up the air.
    JP1 
    						
    							69 -2448ES—03 8
    Quick Installation Guide
    Set jumper JP2, on the back of the thermostat, if you have a heat pump.
    Set Heat Pump Reversing Valve7
    OLeave the jumper in this factory-set position if you have connected O wire to the O/B terminal.
    BPlace the jumper to this position if you have connected B wire to the O/B terminal.
    Incorrect jumper setting: The heat pump operation will be reversed, i.e., it will cool in Heat mode and will heat in Cool mode.