Have a look at the manual Honeywell thermostat ST9100A 1 Day Single Channel Time Switch User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

11 OPerATING YOUr ST9100A Overriding the Operation Without Changing the Programme In AUTO and ONCe operating modes, the OVerrIDe button switches the system ON or OFF without altering the programme. When the indicator lamp is ON, pressing the OVerrIDe button switches the system OFF until the next programmed ON time. When the indicator lamp is OFF, pressing the OVerrIDe button switches the system ON until the next programmed OFF time. The LoT™ Display will provide you with information about the override. The extra Hour Function The eXTrA HOUr button allows you to switch the system ON for up to 3 extra hours without altering the programme. Pressing the button once will give one extra hour. The LoT™ Display will display the message ‘+ 1 HOUR’, to confirm the button has been pressed. When the green INDICATOr LAmP is OFF, pressing the eXTrA HOUr button switches the system ON for just one hour. When the green INDICATOr LAmP is ON, pressing the eXTrA HOUr button extends the programmed ON period by one hour. Further presses of the eXTrA HOUr button will increase the extra hour period by one hour for each button press, up to a maximum of 3 hours. The LoT™ Display will continue to provide information on the extra hour status. To cancel the extra hours, just keep pressing the eXTrA HOUr button until the ‘CANCELLED’ message appears on the LoT™ Display.

12 FINe TUNING YOUr ST9100A Changing from Am/Pm Time Display to the 2 Hour Clock Your ST9100A can operate on the 12 hour AM/PM or 24 hour clock formats. To change the format, ensure the slider is in the rUN position then press and hold the and buttons together for about 2 seconds. Ignore the ‘NOT VALID’ message that will appear briefly. All the displayed times will be automatically changed to the new format. Repeating this procedure will change the clock display back to the original format. Changing the Installer Parameters The ST9100A has a special Installer Mode where some features can be adjusted to suit your lifestyle or preferences – these are called Installer Parameters, and are listed in the table below, along with a description of the options that are possible. INSTALLer PArAmeTerParameter NumberDefault ValueOptionsDescription 24hr or am/pm clock display.11212, 2412 = am/pm display,24 = 24hr display Configure backlight operation.220, 1, 20 = off, 1 = on if button pressed,2 = on continuously Enable/disable auto time change.310, 10 = disabled, 1 = enabled Number of ON/OFFs per day.522, 32 = 2 on/offs per day,3 = 3 on/offs per day Select default time programme.6AA, b, CA = standard, b = at home,C = economy Reset all parameters810, 10 = do not reset1 = default parameters

1 FINe TUNING YOUr ST9100A To enter Installer mode: a. Ensure the slider is in the rUN position, then press and hold and buttons together for 8 seconds. Ignore the ‘NOT VALID’ message that is displayed for a few seconds. The message ‘SET UP MENU’ will show briefly, followed by ‘SET INSTALLER OK ?’ b. Press the button to take you into the Installer Mode Parameter Menu. c. Parameter 1 is now available to change. This is to allow you to change the clock format from 12 hour AM/PM to 24 hour. At every step, the LoT™ Display will inform you what the parameter means and what option you have selected. The parameter number is shown on the display separated by a colon from the parameter value. d. You can change the parameter value by pressing the or buttons. At this point the description in the LoT™ Display will change and the parameter value will flash. If you press the value will stop flashing and be saved for use. e. Press to move to the next parameter available for editing. f. Keep pressing to step around the list of parameters, and use or buttons to change the parameter value. g. Any parameter changes that have been confirmed with the button will be saved and used. To exit Installer mode: h. You can exit Installer Mode at any time by moving the slider to the next position and then back again to rUN. Note: Installer Mode will exit automatically after 10 minutes if the slider is not moved.

1 FAQ AND TrOUBLeSHOOTING How do I set the time only, if the ST9100A clock is not correct? Your ST9100A contains a very accurate digital clock that is factory pre-set. Should you ever need to change the time, just follow this procedure: a. Move the slider to the DAY/TIme position. b. Keep pressing the green button until the message ‘SET THE TIME’ is displayed. To change the time, press the or buttons until the correct time is shown. The message ‘IS TIME OK?’ will be displayed. Press the green button to confirm the time is correct. If you have made a change, the message ‘TIME SAVED’ will show, followed quickly by ‘DATE + TIME COMPLETE’. c. Move the slider to the rUN position, to complete changing the time. What do I do when the clocks go back in October and forward in march? Your ST9100A is factory-set to adjust the clock automatically at the correct dates, so you should never need to adjust the clock forward or backwards yourself. It is possible to disable this particular feature, as described in the section ‘Changing the Installer Parameters’ (page 12). You may also check the section ‘Configuration & Service Data’ (page 18) to see how your Installer has configured your product. What should I do if I get ‘lost’ while programming the ST9100A? The LoT™ Display on ST9100A will provide you with help and tips to work through the programming. Should you ever get ‘lost’, the simplest thing to do is to move the slider to the rUN position, and then move it back to the appropriate programming position where you got lost. At this point just follow the instructions again. What happens if there is a power failure? In the event of a mains power failure, the ST9100A display will go blank, the indicator lamp will go out, and the control output will switch off. The real time will be constantly maintained by means of the built-in battery backup, ready to power back up as if nothing had happened when the mains power is restored. In addition, all programmes and settings are stored in a special memory (called NV memory) which requires no power to maintain information, and so will be retained indefinitely. Should the correct time and date ever be lost, for whatever reason, the message ‘SET DATE + TIME’ will be displayed whilst the slider is in the rUN position. In this case, simply follow the procedure described under ‘Step 1: Setting the Date & Time’ (page 4). It should not be necessary to make any changes to your programmes.

1 SymptomPossible Causeremedy ST9100A has a blank LCD displayNo power to the systemCheck that there is power to the system Fault in ST9100ACall Installer ST9100A indicates that the system is ON, but radiators are cold and/or taps are running with cold water. Temperature controls are switched off or set too low Check that the temperature controls in the system are set to appropriate levels Boiler or other system controls have malfunctioned Call Installer ST9100A shows the message ‘INTERNAL FAULT’ Fault in ST9100ACall Installer Troubleshooting Guide This is a quick guide to help you diagnose and cope with possible problems with ST9100A. For further assistance, please contact your Installer. FAQ AND TrOUBLeSHOOTING

150022737-001 B CONFIGUrATION & SerVICe DATA Configurable FeaturesOptionsInstaller Configured (tick appropriate box) 24hr or am/pm clock displayam/pm display 24hr display Display backlight operationOff On if button pressed On continuously Automatic time changeEnabled Disabled Number of ON/OFFs per day2 on/offs per day 3 on/offs per day Default programmeA = standard b = at home C = economy Configuration Data (to be completed by Installer) The table below is for the Installer to complete to indicate how your ST9100A has been configured.