Page 31

*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.
5 - 13
SOFTWARE ADJUSTMENT (continued)
ADJUSTMENT
ITEM (2)
S-METER
(MAIN BAND)
(SUB BAND)
ADJUSTMENT ADJUSTMENT CONDITION DISPLAY OPERATION
• Enter software adjustment mode (Refer
page 5-12).
• Push [2] key to enter the S-meter adjust-
ment
• Connect an SSG to [VHF ANT] connector
and set as :
Frequency : 146.0200 MHz
Level : OFF
• Receiving
• Set an SSG as :
Frequency : 146.0200 MHz
Level : 3.2 µV* (–97 dBm)
•...

Page 32

*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.
5 - 14
SOFTWARE ADJUSTMENT (continued)
S-METER
(SUB BAND)
ADJUSTMENT
ITEM (3)
NOISE SQL
(MAIN BAND)
(SUB BAND)
ADJUSTMENT ADJUSTMENT CONDITION DISPLAY OPERATION
• Set an SSG as :
Frequency : 146.0200 MHz
Level : OFF
• Receiving
• Set an SSG as :
Frequency : 146.0200 MHz
Level : 3.2 µV* (–97 dBm)
Modulation : OFF
• Receiving
• Set an SSG as :
Frequency : 146.0200 MHz
Level : 32 µV* (–77 dBm)
• Receiving
• Connect...

Page 33

*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.
5 - 15
SOFTWARE ADJUSTMENT (continued)
ADJUSTMENT
ITEM (4)
CENTER
(MAIN BAND)
ADJUSTMENT
ITEM (5)
FILTER
CALIBRATION
(MAIN BAND)
(SUB BAND)
ADJUSTMENT ADJUSTMENT CONDITION DISPLAY OPERATION
• Connect an SSG to [VHF ANT] connector
and set as :
Frequency : 146.0200 MHz
Level : 5.6 µV* (–92 dBm)
Modulation : OFF
• Receiving
• Connect an SSG to [VHF ANT] connector
and set as :
Frequency : 146.0200 MHz
Level : 5.6 µV*...

Page 34

*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.
5 - 16
SOFTWARE ADJUSTMENT (continued)
ADJUSTMENT
ITEM (6)
RF PEAK
ADJUSTMENT
ITEM (7)
TX POWER/
METER
(for 144 M)
(for 1200 M)
ADJUSTMENT ADJUSTMENT CONDITION DISPLAY OPERATION
• Enter software adjustment mode (Refer
page 5-12).
• Push [6] key to enter the RF peak adjust-
ment for TX.
• Connect an RF power meter to [VHF ANT]
connector.
• Connect an SSG to P501 on the PA unit
via the JIG cable (A) and set as:...

Page 35

5 - 17
SOFTWARE ADJUSTMENT (continued)
TX POWER/
METER
(for 430 M)
ADJUSTMENT
ITEM (8)
DEVIATION
ADJUSTMENT ADJUSTMENT CONDITION DISPLAY OPERATION
• Connect an RF power meter to [UHF ANT]
connector.
• Enter software adjustment mode (Refer
page 5-12).
• Push [8] key to enter the deviation adjust-
ment.
• MIC gain : Center
• Connect an FM deviation meter to [VHF
ANT] connector through an attenuator and
set as:
HPF : OFF
LPF : 20 kHz
De-emphasis : OFF
Detector : (P–P)/2
• Connect an audio generator to [MIC]...

Page 36

*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.
5 - 18
5-7 UX-910 ADJUSTMENTS
2ND LO LOCK
VOLTAGE
1ST LO LOCK
VOLTAGE
RECEIVER
GAIN
ATT GAIN
IDLING
POWER
BALLANCE
TRANSMITTER
GAIN
ADJUSTMENT
ADJUSTMENT ADJUSTMENT CONDITIONMEASUREMENT
VALUEPOINT
UNIT LOCATION UNIT ADJUST
1
1
2
1
1
1
1
2
3
4
1• Connect an optional UX-910 (1200
MHz band unit).
• Display frequency: 1270.5000 MHz
• Receiving
• Display frequency: 1240.0000 MHz
• Receiving
• Display frequency:...

Page 37

5 - 19
CP501
1st LO lock voltage 
check point
C332
Power ballance 
adjustment
CP322
Idling check point
CP321
Idling check point
R13
Idling adjustment
R67
APC adjustment
R83
Transmitter gain 
adjustment
R224
Receiver gain 
adjustment
CP15
APC check point
CP701
2nd LO lock voltage 
check point
CP311
Receiver gain
check point
CP401
APC check point
R61
APC adjustment
R37
APC adjustment
R288
Attenuator adjustment 

Page 38

*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.
5 - 20
UX-910 ADJUSTMENTS (continued)
APC
(POWER SET)
ADJUSTMENT
ADJUSTMENT ADJUSTMENT CONDITIONMEASUREMENT
VALUEPOINT
UNIT LOCATION UNIT ADJUST
1
2
3
4
5• Display frequency: 1270.0000 MHz
• Mode : CW
• Connect an SSG to the check point
CP311 and set as :
Frequency : 10.8500 MHz
• Transmitting
• Transmitting
• Transmitting
• Transmitting
• TransmittingRear
panel
MAIN
(UX-910)
Rear
panel
MAIN
(UX-910)
Connect an...

Page 39

5 - 21
R67
APC adjustment
CP15
APC check point
CP311
Pre-setting for 
APC adjustment
CP401
APC check point
R61
APC adjustment
R37
APC adjustment 

Page 40

[DISPLAY BOARD]
6-1 IC-910
[FRONT UNIT]
S.=Surface mount
W1 8900006700 CABLE OPC-645 (N:6 L:60) 
W2 8900006700 CABLE OPC-645 (N:6 L:60)
W3 8900006700 CABLE OPC-645 (N:6 L:60)
W4 8900009240 CABLE OPC-909 (P=1 N=10 L=110)
W5 8900006700 CABLE OPC-645 (N:6 L:60)
W6 8900006700 CABLE OPC-645 (N:6 L:60) 
EP1 6910012480 E.OTHER RMS20-250-201-1R 
EP2 6450001230 E.OTHER HLJ0999-01-480 
IC1 1140009671 S.IC M30622MAA-868FP 
IC2 1130009970 S.IC SED1540F0A
IC3 1130009100 S.IC BU4052BCFV-E2
IC4 1130009100 S.IC...