Kenmore Quiet Comfort 7 Manual
Have a look at the manual Kenmore Quiet Comfort 7 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 23 Kenmore manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CleaningofHumidifier CAUTION:Toreducetheriskof injury,fireordamagetohumidifier, useonlycleanersspecificallyrec- ommendedforhumidifiers.Never useflammable,combustibleorpoi- sonousmaterialstocleanyour humidifier.Toavoidscaldsand damagetohumidifier,neverputhot waterinhumidifier. CAUTION:Localwaterpuritymay varyfromareatoareaandundercer- tainconditionswaterimpuritiesand airbornebacteriamaypromotethe growthofmicroorganismsintheres- ervoirofahumidifier. Toretardbacteriagrowththatmay causeodorsandbeharmfultoyour health,useonlySearsreplacement filters.Weals0recommendusinga EPAapprovedbacteriostat,42-14900 andhumidifiercleaner42-14713, availableatyourlocalSearsstore. NOTE:Ifitisnecessarytouseapproved bacteriostat,fotlowttledirectionscor- rectly. Thebottleofthewhoiehousehumidifierwill hold2-I/2gallonsofwater. Step! Tomakecleaningeasier,thewaterresero voirshouldbeemptyandcompletely driedout.Toaccomplishthis.usethefol- lowingmethod: a.A_lowthehumidifiertorununtilthe automaticshutoffturnsthehumidifier OFF, b.Unplughumidifier WARNING:Ifhumidifierisnot] unplugged,fancouldstartafter 1 housingisremoved. c,Followinstructionsinstep2belowTo RemoveParts d.Afterremovingtheparts,dryoutthe bottomofthehumidifiercabinet, e.ProceedtoBi-WeeklyMaintenance_or EndofSeasonMaintenance. Step2 TORemoveParts a,Removethewaterbottlecoverandthe waterbottle.Setpartsaside b.Liftand_ernovethefanassemblyand setaside. c.RemovethefitterhousingBefore removingtheinternalpartsofthe flurnidifiercabinet,werecommend movingthehumidifiertoanareawhere floorcoveringsarenotsusceplib_eto waterdamage,i.e.,kitchenorbath area. d,Removethefiltersandthewater_evel float. eThecabinetshouldbeempty,ifany waterisinthecabinet,emptyasnec- essary f,ProceedtoBi-WeeklyMaintenanceo_ EndofSeasonMaintenanceCon- tinuetocleancabinetandinternal padsasdescribedbelow Step3 Installnewfilters(purchasetheco_ec_ evaporativewickingfilterpads42.-14909 foryourhumidifier)intothelocationwhere theoldfilterswerepositionedReplacefit- terhousingReinstallthewaterlevelfloat intothecabinet,Positionthefanassenrbly ontopofthecabinetandreplacethe waterbottleandwaterbottlecoverThe unitisreadyforstorageoroperational _Jse, 11
CleaningofHumidifier(continued)------------ Bi-WeeklyMaintenanceRinsewithwateruntilbleachsmeltis RemovingScale 1.Fillthewaterreservoirwithone8oz. cupofundilutedwhitevnegarLet solutionstay20minutes. 2.Cleannitinteriorsurfaceswithsoft brush.Dampensoftclothwithundiluted whitevinegarandwipeoutthewater reservoirtoremovescale 3.Rinsethoroughlywithcleanwarmwater toremovescaleandcleaningsolution beforedisinfectingthewaterreservoir. 4.Dustthefanassemblyandoutsidesur- faceswithasoftclothonly. DisinfectingWaterReservoir andBase gone.Allowunittodryoutcompletely. 3.Waterbottleshouldbecleanedinsame manner. EndofSeasonMaintenance 1,Followbi=weeklymaintenanceinstruc- tionsatendofhumidificationseasonor whenhumidifierwillnotbeusedforat leastoneweekormore. 2.Removeandthrowawayfilters. 3.Lethumidifierdrycompletelybefore storing.Donotstorewithwaterinside cabinetorwaterbottle, 4.Storeincool,drylocation. 5.Installnewfiltersincleanhumidifier beforenextseasonbegins. 1.FillwaterreservoirwithIteaspoon chlorinebleachin1gallonwater.Let solutionstay20minutes,swishing everyfewminutes.Wetallsurfaces normallyexposedtowater. 2.Emotywaterreservoirafter20minutes. 1:2
Troubleshooting--.,.,.,,..,., TroubleProbableCause Unitwiltnotrun.oHumiditylevelistoohigh -Nopower *Floatisnotfree Unitwil_notshutoff. Unitwillnotdryout completely Bottlecontinuesto empty. Unitisnotemptying. Unitrunsandshuts offbeforebottleis empty •Waterispresentinthe system •Highhumidityorlow temperatureresultingin i stowevaporation Airisenteringwaterreser- voirs. Dirtyfilter Reservoircapplunger missingpostinbottomof cabinet. *Humiditylevelistoohigh .Unitisnotsetuponalevel surface(Floatwillnot sensewaterattherearof thecabinet. Remedy Raisehumidistatsetting •Check120voltpowersource •Freefloatfromobstruction ,Thisisnormal.Asmall amountofwaterremainsin thecabinet. •Allowunittocontinueopera- tion. •CheckE-Z-FillSide-Capsto •ensuretightness. Checkforleakinwaterbottle. •AregasketsforE-Z-FillSide- Capsinplace(seerepair partsfist). •Changetoafreshnewfi}ter. •Checkorientationofbottle. Repositionsothatreservoir capplungerisdepressedby postinbottomofcabinet. ,Raisehumidistatsetting(if possible) •Positionunitlevel(Somecar- petpaddingmayallowunitto setlowerontheleftsidethan therightsideduetotheweight ofthewaterbottleonleftside. Installcoastersunderleftcast- ers.) CAUTION:Useonly42-14900EPARegisteredBacteriostatavailablefrom SearsRetailstore, Useofotherwatertreatmentproductsmaydamagethefilterelements. Undernocircumstancesshouldyouusewatertreatmentproductsdesigned forRotobeltorUltrasonichumidifiers. t3
RepairParts PartsListForSearsHumidifiers ModelNo.758.144510 22 _6 / t4
RepairParts., PartsListForSearsHumidifiers ModelNo.758.144510 Alwaysorderbypartnumber.Notbykeynumber PartNo. iI825807 825837 825809 822452-2 825857 822406-1 816069-2 822405-6 STD611007 10823735 11825848 1242-14909 i13825847 i14I14909 15822120 16825867 17823712-2 18824101-1 19STD610803 20825806 21823728 22825855 2313805-02 24818983 25825858 26i822419-2 27819027 28819026 29821421-1 30819024 31824690 32825849 _821904 SP6054 Description Cover;Bottle LidStationary CoverControl Knob LabelControl Fan ScrPanHdAB#6x1-3/4 Motor *Scr.PanHd,TyAB°10x3/4 SupportMotor HousingFilter 1FilterEvaporative RailKick Scr,PanHd.TyB#4x5/8 CasterTwinWheel Cabinet FloatWaterLevel RetainerFloat *ScrewPanHd.TyAB8x3/8 CoverElectronics SwitchMicro RetainerMicroSwitch Humidistat SwitchThreeSpeed LightPilot CapValve StemValve SpringValve RingO SealValve E-Z-FillSide*Cap Bottle Cordw/Ptug OwnersManual(NotIllustrated) *StandardHardwareItem-Maybepurchasedlocally 1Stockitem-MaybesecuredthroughtheHardwareDepartmentofmostSearsretail stores. 15
Forthe Call7am-7pro,7daysaweek 1-800-366-PART (1-800-366-7278) Forin-homemajorbrandrepairservice Call24hoursaday,7daysaweek 1-800-4-REPAIR (1-800-473-7247) Forthelocationofa SearsRepairServiceCenterinyourarea Call24hoursaday,7daysaweek 1-800-488-1222 ForinformationoupurchasingaSears MaintenanceAgreementortoinquire abouta,existingAgreement Call9am-5pro,Monday-Saturday 1-800-827-6655 S£/ARS AmericasR_p_rSpecialists ThemodelnumberwillbefoundontheHumidifierIdentification label. Whenrequestingserviceororderingparts,alwaysprovidethe followinginformation: •ProductTypeoModelNumber •PartNumber.PartDescription ©1998EmersonElectricCo. Sears,RoebuckandCo.,HoffmanEstates,1L60179U.S.A. PartNo,SP6054FormNoSP6054-1PrintedinCanada6/98