Page 11
10 5. OPERATION Water temperature selector Press the button to select water temperature. The water temperature [60 C ➔95C➔Cold ➔ 30 C ➔40C] can be selected in Cotton. 95C is selected for Cotton and Baby Care. Option Rinse+ Used to additional rinse, which may assist in removing traces of detergent residue. • By selecting Rinse+ function, the rinse time and the rinse water are increased. Pre Wash If the laundry is heavily soiled, “Pre Wash” course is effective. Pre Wash is available in Cotton and...
Page 12
11 Start/Pause button Use the button to start or pause wash cycle. The power turn off automatically 4 minutes after the pause button is pressed. Spin WD-10480S/N/T WD-10490S/N/T Rinse Hold ➔No Spin ➔ 400 ➔ 800 ➔ 1000 WD-80480S/N/T WD-80490S/N/T Rinse Hold ➔No Spin ➔ 400 ➔ 800 Time Time Save By selecting the Time Save option, the wash time may be reduced, depending on the program selected. Time Delay Press the button when reservation washing is needed. When the button is pressed, [ ] is...
Page 13
12 6. WIRING DIAGRAM/ PROGRAM CHART YL BK WASHING HEATER BLYL * Water Supply : WÆS * Intermittent Spin : IÆS * Disentangle : DÆT * Basic Cycle * Optional Cycle * Pre-Setting Time : Water Supply - 120 sec. * Basic time is minute i Drain - 60 sec....
Page 15
14 7-5.ERROR DISPLAY. ERROR SYMPTOM CAUSE 1WATER INLETWater has not reached to the pre-set level within 4 min. since ERRORinlet valve operated, or water has not reached to the normal level within 25 min. 2IMBALANCEThe appliance is tilted. ERRORLaundry is gathered to one side. Non distributable things are put into the drum. 3DRAIN ERROR Water has not drained enough within 5 min. 4OVERFLOW Water is automatically being pumped out because too much ERROR water is in the tub. 5SENSOR PRESSURE The sensor...
Page 16
15 8-1.DIAGNOSIS AND ANSWER FOR ABNORMAL OPERATION 8. ERROR DIAGNOSIS AND CHECK LIST SYMPTOM GUIDE FOR SERVICE CALL NO POWER Water inlet trouble YES YES YES NO NO YES NO NO Is the power plug connected firmly to 220-240V~ outlet? Power failure? or Breaker opened? Is the outlet controlled by a switch. Visit to check Is displayed? Is the tap opened? Is the tap frozen? Is the water supply shut-off? Is filter in the inlet valve clogged with foreign material? Visit to check Clean the filter of inlet valve
Page 17
16 SYMPTOM GUIDE FOR SERVICE CALL DOOR OPEN ERROR Refer to 7-3 ERROR DISPLAY Drain Trouble NOYES YES NO NO YES Did you press the Start/Pausebutton when the door is open? Visit to check Check if the door switch is O.K Is displayed? Is the debris filter clogged with foreign material such as pins, coins, etc.? Is the drain hose frozen with water, kinked, or crushed? Visit to check Close the door Clean up the filter.
Page 18
17 SYMPTOM GUIDE FOR SERVICE CALL Suds overflow from the appliance. (In this condition, wash and spin do not operate normally) No effect of softener YES YES YES YES YES Is low-sudsing detergent for the durm washing machine used? Is the proper amount of detergent used as recommended? Recommend to reduce the amount of detergent. Is softener put in the correct compartment of drawer? Is the drawer closed during wash? Is the softener cap...
Page 19
18 8-2.FAULT DIAGNOSIS AND TROUBLESHOOTING 1. Be careful of electric shock or disconnecting the parts while troubleshooting. 2. First of all, check the connection of each part terminal with wiring diagram. 3. If you replace the PWB assembly (Main), put in the connectors correctly. CAUTION NO NOYES YES YES NO NO YES PWB ASSEMBLY 12 Check the fuse Check the harness Assembly. When measuring the voltage of the outlet, is the voltage AC 220-240V? When measuring the voltage of pin
Page 20
19 NO YES NO YESNO YES NO NO YES YES YESNO NO NO YES Wiring diagram option (HOT) option (HOT) MAIN WASH : Detergent WASHPRE - WMAIN SOFTENERASH MAXmax Is the water supply shut-off? Is the tap opened? Is the inlet valve filter clogged with impurity? Is resistance of the inlet valve connector between the 2 to 8 kΩ? Check the voltage between each terminals of inlet Valve is 220 - 240V~. (Refer to 7-2 TEST MODE) Is water supplied? Are receptacles correctly connected to the terminals of inlet valve? Is...