    							CHAPTER 3  TROUBLESHOOTING
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 63
    PN-DAIF 
    (DAIF)RUN lamp is not 
    flashing.Abnormal operation 
    of DAIF card1 Reset the MB switch.
    (Down→Up→Down)
    2 If the fault cannot be 
    cleared, replace the card.
    LINK lamp is not on. Layer 2 link connec-
    tion failure between 
    DAID and DAIE1 Check to see if the cable 
    between DAID and DAIE is 
    correctly connected. Refer 
    to Connection Between 
    Main Site and Remote Site 
    on Page 47.
    2 Reset the MB switch.
    (Down→Up→Down)
    3 Check whether cable 
    between DAIF cards is 
    correctly connected. Refer 
    to Connection Between 
    Main Site and Remote Site 
    on Page 47.
    RMT lamp is on. Remote alarm Check to see if the cable 
    between DAIF cards (sending 
    side) is correctly connected. 
    Refer to Connection Between 
    Main Site and Remote Site on 
    Page 47.
    PN-DAIF 
    (DAIF)PWR lamp is on. PCM signal loss Check to see if the cable 
    between DAID and DAIE is 
    correctly connected. Refer to 
    Connection Between Main 
    Site and Remote Site on Page 
    47.
    Table 3-1  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUS FAULT CONTENT REMEDIAL ACTION 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 64  ND-70917 (E), Issue 1.0
    CHAPTER 3  TROUBLESHOOTING
    PN-M10 (M10) CK0 lamp is not on. Cable connection 
    failure between Digi-
    tal Trunk Interface 
    and No. 0 circuit of 
    M101 Check to see if the cable 
    between Digital Trunk Inter-
    face and M10 is correctly 
    connected.
    2 Check the switch setting of 
    M10.
    3 If the fault cannot be 
    cleared, replace the card.
    CK1 lamp is not on. Cable connection 
    failure between Digi-
    tal Trunk Interface 
    and No. 1 circuit of 
    M101 Check to see if the cable 
    between Digital Trunk 
    Interface and M10 is 
    correctly connected.
    2 Check the switch setting of 
    M10.
    3 If the fault cannot be 
    cleared, replace the card.
    TALM lamp is on. Optical output line 
    fault1 Check to see if the cable 
    between Digital Trunk Inter-
    face and M10 is correctly 
    connected.
    2 Check the switch setting of 
    M10.
    3 If the fault cannot be 
    cleared, replace the card.
    RALM lamp is on. Optical input line 
    fault1 Check to see if the optical 
    cable between the own side 
    M10 and remote side M10 is 
    correctly connected.
    2 Check the switch setting of 
    M10s on both side.
    3 If the fault cannot be 
    cleared, replace the card.
    Table 3-1  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUS FAULT CONTENT REMEDIAL ACTION 
    						
    							NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 65
    CHAPTER 4
    CIRCUIT CARD 
    INFORMATION
    This chapter explains the mounting location, the meaning of lamp in-
    dications, and the method of switch settings of each circuit card for the
    Remote PIM. 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 66  ND-70917 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    How to Read This Chapter
    HOW TO READ THIS CHAPTER
    This chapter explains each circuit card used in this system. Explanations are given in alphabeti-
    cal order of the circuit card names within each circuit card category (Control, Application Proces-
    sor, and Line/Trunk).
    (1) Locations of Lamps, Switches, and Connectors
    The locations of lamps, switches, and connectors of each circuit card are shown by a face 
    layout.
    (2) Lamp Indications
    The name, color, and functions of each indicator lamp equipped on each circuit card are 
    described in a table.
    (3) Switch Settings
    The name, settings, and functions of each switch equipped on each circuit card are 
    described in a table.
    Each switch setting table has a CHECK column. Make necessary entries in the CHECK column
    during and/or after the system installation and maintenance, and use each table as a reference
    for subsequent system maintenance and operations. 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    Mounting Location of Circuit Card
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 67
    MOUNTING LOCATION OF CIRCUIT CARD
    This section explains the conditions for mounting circuit cards for the Remote PIM.
    Figure 4-1 shows circuit card mounting slots allocated in the PIM.
    Figure 4-1  Mounting Location of Circuit Card
    *1PN-CP15 card must be mounted in FP11 slot on Main Site PIM0 for Remote PIM system.
    *2PN-CP15 card in FP12 slot on Main Site PIM2, 4.
    *3PN-DAIA/PN-DAID card in the AP00-AP11 slots on Main Site PIM0, 2, 4.
    For mounting the DAIA/DAID card on the AP11 slot, the CN connector on the DAIA/DAID 
    card should be used.
    When the clock signal is supplied from the T1/E1 line, mount DAIA/DAID cards (DAIA0/
    DAID0, DAIA1/DAID1) on PIM0 in order to receive the clock signal.
    *4PN-DAIB/PN-DAIE card in the MP slot on the Remote PIM.
    *5PN-DAIC/PN-DAIF card in the AP00-AP11 slots on Main Site PIM0, 2, 4, and in the AP00-
    AP11 slots on the Remote PIM.
    *6PN-M10 card in the LT00-LT11 slots on Main Site PIM0, 2, 4, and on the Remote PIM.
    LT09/AP09LT08/AP08LT07/AP07
    LTC1LTC0LTC2
    PIM
    FRONTAC/DC
    PWR
    LT10/AP10LT00/AP00LT01/AP01LT02/AP02LT03/AP03LT04/AP04LT05/AP05LT06/AP06LT11/AP11/FP11MP12/FP12
    LTC3
    DC/DC
    PWR
    PFTVM
    *3*2
    *4
    BWB
    *1*5 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 68  ND-70917 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    List of Required Cards
    LIST OF REQUIRED CARDS
    Table 4-1 shows the required cards that are explained in this section.
    *MB = Make Busy
    Table 4-1  List of Required Cards
    NAME
    (FUNCTIONAL
    NAME)LAMP
    X: PROVIDED
    –: NOT 
    PROVIDEDSWITCH
    X: PROVIDED
    –: NOT 
    PROVIDEDEXTRACTION/
    INSERTION WITH 
    POWER ON
    X: ALLOWED
    : ALLOWED 
    AFTER MB*
    –: NOT ALLOWEDREFERENCE
    PA G E
    PN-CP15 (FP) X XPage 69
    PN-DAIA (DAI) X XPage 71
    PN-DAIB (DAI) X XPage 76
    PN-DAIC (DAI) X XPage 80
    PN-DAID (DAI) X XPage 83
    PN-DAIE (DAI) X XPage 89
    PN-DAIF (DAI) X XPage 93
    PN-M10 (M10) X XPage 97 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-CP15 (FP)
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 69
    PN-CP15 (FP)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while the circuit card is operating normally
    SENSE
    RU N
    MB
    SW1 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 70  ND-70917 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-CP15 (FP)
    Switch Settings
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and    , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
    ging the circuit card. 
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE 
    (Rotary SW)
    NOTE 10-3For setting FP No.
    0 For mounting this card in PIM0
    1 For mounting this card in PIM2
    2 For mounting this card in PIM4
    3 For mounting this card in PIM6
    4-F Not used
    MB (Toggle SW)
    NOTE 2
    UPFor make-busy
    For normal operation
    SW1
    (Piano Key SW)1-3Not used
    4For normal operation
    OFFNot used
    0
    1
    2
    3
    ON
    DOWN
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    ON 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-DAIA (DAI)
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 71
    PN-DAIA (DAI)
    Location of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally
    LINK Green Remains lit when a link between this card and a distant office is 
    normally connected
    Goes out after 15 seconds of link disconnection
    RED Red Remains lit when detecting PCM signal loss or Frame Alignment 
    signal loss
    RMT Red Remains lit when receiving the alarm signal from a distant office
    LOOP – Not used
    PWR – Not used
    BL Red Remains lit while data transmission on control channel (D ch)
    Flashes while FP data downloading
    JPS
    JPR
    SW2
    SW3BUS
    PCM1
    PCM0
    CNSENSE
    RUN
    MB
    SW1LINK 
    RED 
    RMT 
    LOOP 
    PWR 
    BL 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 72  ND-70917 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-DAIA (DAI)
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 10-FFP (Firmware Processor) Number setting for the
    DA I A c a rd
    By this setting, the system regards the DAIA card
    and the opposite DAIB card as one Firmware Pro-
    cessor
    0 Not used
    1FP No. 1
    2FP No. 2
    3FP No. 3
    4 – F Not used
    MB (Toggle SW)
    NOTE 2
    UP For make-busy
    For normal operation
    SW1
    (Piano Key SW)1
    NOTE 3ONFor supplying 1.5 MHz clock to 
    PLO 0
    No clock supply to PLO 0
    2
    NOTE 3ONFor supplying 1.5 MHz clock to 
    PLO 1
    No clock supply to PLO 1
    3 Always set to OFF
    4 Always set to OFF
    (Continued)
    1
    32
    ON
    DOWN
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF
    OFF 
    						