    							NEAX2400 IMX Feature Programming Manual
    ND-70184 (E), Issue 3
    Page 87
    Brokerage - Hotline B-6
    B-6 Brokerage - Hotline
    General Description
    This feature provides a HOT LINE [H-1] function for Dterm.
    Operating Procedure
    1. Lift handset or press the SPEAKER key.
    2. Press sub-line key associated with the predetermined desired station. The destination station is
    automatically dialed; Ringback tone is heard, the destination station answers.
    3. After completion of conversation, hang up or press the SPEAKER key.
    Note:
    To make another HOT LINE [H-1] call instantaneously, press another sub-line key without going on-hook and off-
    hook.
    4. If the desired station is busy, while hearing busy tone, press the EXECUTIVE RIGHT-OF-WAY (OVER)
    key; receive warning tone. The caller can override the call in progress.
    Service Conditions
    1. One of the line/feature keys must be assigned as a My Line.
    2. A station Hot Line (calling party) cannot belong to a Hunt [S-7, 8, or 9] or UCD [U-1] group.
    3. Single line station or virtual lines (SOFTWARE LINE APPEARANCE [S-33]) can be assigned as a
    BROKERAGE HOT LINE destination.
    4. When a Hot Line call is made from a D
    term, the Dterms display shows the destination telephone number
    but doesnt show the SERVICE DISPLAY [S-25] of hot line.
    5. This hot line feature is applicable for intra-office connection within the system.
    6. My Line of a D
    term cannot be assigned as a Hot Line feature button.
    7. Destinations must be stations or an ATTENDANT CONSOLE [A-3] of the system.
    8. When a destination is an ATTENDANT CONSOLE [A-3], the Hot Line call terminates as an ATND call.
    9. ATTENDANT CAMP-ON [A-1], EXECUTIVE RIGHT-OF-WAY [E-1], CALL WAITING [C-31] and
    CALL BACK [C-1] can be prohibited to the hot line connection through CLASS OF SERVICE -
    INDIVIDUAL [C-15].
    10. When a destination station is busy, STEP CALL [S-13], CALL BACK [C-1], CALL WAITING [C-31],
    or MESSAGE REMINDER - D
    term [M-19D] cannot be activated.
    11. Station Hunting works if the destination station is in a hunt group.
    12. UCD function works if the destination station is a UCD station, but busy tone is given if all the UCD
    stations within the group are busy (no UCD queuing).
    13. CALL FORWARDING [C-2, 3, 5] is allowed if the destination station has set Call Forwarding, but CALL
    FORWARDING - OUTSIDE [C-28] cannot be provided.
    14. Overriding is available only via the OVER key on D
    term. If switch hook flash is attempted, the caller
    receives reorder tone.
    15. In the following cases, overriding by the OVER key is not available, and the caller receives reorder tone. 
    a.) the conference-function trunks are all busy.
    b.) the destination station is not engaged in a two party call, as when
     call is terminating to the destination station.
     the destination station has a call on hold. 
    						
    							NEAX2400 IMX Feature Programming Manual
    Page 88ND-70184 (E), Issue 3
    B-6 Brokerage - Hotline
    Service Conditions (cont’d)
     the destination station is off-hook.
     the destination station is already engaged in a three-party call.
    c.) the destination is the Attendant or is connected to an outside party.
    16. When EXECUTIVE RIGHT-OF-WAY [E-1, E-1D] is used with this feature, it is not activated under any
    of the following conditions:
     when utilizing EXECUTIVE RIGHT-OF-WAY [E-1, E-1D] service using switch hook flash and
    access code.
     when all three-party conference trunks are busy.
     when the destination is not in the two-party connection (an incoming call is in the middle of terminating
    to the destination or the destination places a call on hold or the destination is in off-hook status or the
    three-party connection including the destination has already been established).
     when the destination is connected with the Attendant Console or the C.O. trunk.
    17. This feature can be activated via FCCS.
    18. Only the station assigned a telephone number is available for the station assignment when activating this
    feature via FCCS.
    19. The station, the Attendant Console/Desk Console (operator call), and the trunk can be a destination for
    Hotline.
    20. When Call Forwarding - All Calls/Busy Line/Don’t Answer service has been set to the called station, these
    features are available for the call to the station.
    21. When a calling party encounters a busy station, the call may bridge into the connection, depending on the
    data assigned by the ASYD command.
    Programming
    STEP 1:ASDT - Assign to a PA-16LC circuit the following data:
    TN: Tenant Number
    STN: Station Number
    LENS: Line Equipment Number (6 digits) - Actual LENS for TEC 14, Virtual LENS for TEC 18
    TEC: Telephone Class (1-31)
    1: DP (10pps)
    2: PB
    3: DP/PB
    12: D
    term
    13: Data terminal via Dterm
    14: HOTLINE
    15: CAS Line
    18: Virtual Circuit
    RSC: Route Restriction class (0-15)
    SFC:  Service Feature Class (0-15)
    STEP 2:AHLS - Assign the station numbers programmed above for the following parameters:
    HOT TN:Hotline Tenant
    STN: Hotline Station
    TYPE: 1 = station
    CON TN: Connecting Station’s Tenant
    CON STN: Connecting Station Number 
    						
    							NEAX2400 IMX Feature Programming Manual
    ND-70184 (E), Issue 3
    Page 89
    Brokerage - Hotline B-6
    Programming (cont’d)
    STEP 3:AKYD - Assign to a D
    term a line appearance of the Hotline station number.
    TN: 1
    STN: Station Number
    TP: Type of D
    term (0/1)
    KYN: Key Number (1-40)
    KYI: Service Index
    0: Key not used
    1: Feature Key
    2: Multi-line Key
    KD: 0
    TN, STN:Tenant Number and Station Number of Multi-line (Virtual)
    RG: Ringing Assignment per Multi-Line Appearance
    0: No Ringing
    1: Ringing in Day Mode Only
    2: Ringing in Night Mode Only
    3: Ringing Day and Night
    FCCS Programming 
    This data setting describes only the additional or replacement commands used to activate FCCS
    services. When used as an FCCS feature, these commands replace the non-network commands (for
    example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
    on the node.
    AHLSN - This data must be assigned to the NCN.
    UGN: User Group Number
    TELN: Telephone Number of the calling party
    TYPE: 1 (the called party is a station)
    CON UGN: User Group Number of the called party
    CON TELN: Telephone Number of the called party
    Note:
    The current data should also be set in addition to the command above.
    The command to be set to the node accommodating the calling party: ASDT/AKYD
    The following ASFC command data must be assigned at all nodes to be set BROKERAGE HOTLINE service. SFI=36
    (Brokerage Hotline), RES=1 (allowed)
    Single Line
    TEC: 14
    Assign as STN and 
    CON STN in AHLS
    NEC
    Dterm
    Assign Subline as 
    Virtual: TEC 18
    Assign as STN and 
    CON STN in AHLS Hotline 
    						
    							NEAX2400 IMX Feature Programming Manual
    Page 90ND-70184 (E), Issue 3
    B-8 Boss - Secretary - Message Waiting Lamp Control
    B-8  Boss - Secretary - Message Waiting Lamp Control
    General Description
    This feature allows a secretary, via her station, to control the Call Indicator Lamp (Note) or Message Waiting (MW)
    display on the boss station.
    Note:
    The Call Indicator Lamp is used as the MW Lamp.
    Operating Procedure
    1. CALL FORWARDING [C-3, 5] is not set on Boss station.
    2. An incoming call for Boss station is answered on Secretarys D
    term.
    3. Secretary sets the Call Indicator Lamp or MW display on Boss station. See Procedure 1 below.
    4. Bosss station Call Indicator Lamp or the MW display is on.
    5. Secretary cancels the Call Indicator Lamp or MW display on Boss station.
    To set Message Waiting at a Boss station:
    Procedure 1 (Secretarys station requires a Dterm with a LED)
    1. While remaining connected to the calling party, press the MW SET line/feature key.
    2. The LCD display will indicate MW SET (for 5 seconds, in place of time display). 
    3. MW is set on Boss station. Call Indicator Lamp or the MW display is on.
    4. Secretary will not hear service set tone.
    Procedure 2 
    1. Secretary releases the call after taking the message and presses the RECALL key. Dial tone is heard.
    2. Secretary presses the MW SET line/feature key. LCD will indicate MW SET. Secretary will hear service
    set tone.
    3. MW is set to Boss station. Call Indicator Lamp or the MW display is ON.
    To cancel Message Waiting indication:
    Procedure 1 
    1. While remaining connected, Secretary presses the MW CANCEL line/feature key.
    2. The LCD display will indicate MW CANCEL (For 5 seconds, in place of time display).
    3. Boss MW indication is then cancelled. Call Indicator Lamp or the MW display is OFF.
    Procedure 2 
    1. Secretary presses Boss line appearance. Dial tone is heard.
    2. Press the MW CANCEL line/feature key. Service set tone is heard.
    3. Secretarys LCD will display MW CANCEL.
    4. Boss MW indication is cancelled.
    Service Conditions
    1. Any number of Dterm stations within the system can be assigned to activate this feature.
    2. Secretary must have a D
    term.
    3. Any attempt to set BOSS-SECRETARY MW LAMP CONTROL to a station that already has an MW
    indication will receive MW BUSY following Procedure 1 or a busy tone following Procedure 2.
    4. Any station provided with the sub-line can set or cancel BOSS-SECRETARY MW LAMP CONTROL
    indication on that sub-line.
    5. This feature is not restricted by CLASS OF SERVICE - INDIVIDUAL [C-15] on either the boss or
    secretary stations. 
    						
    							NEAX2400 IMX Feature Programming Manual
    ND-70184 (E), Issue 3
    Page 91
    Boss - Secretary - Message Waiting Lamp Control B-8
    Service Conditions (cont’d)
    6. BOSS-SECRETARY MW LAMP CONTROL indication is cleared by system initialization or a Local
    Processor initialization.
    7. MW control is provided to stations using the D
    term sub-line when: 
    a.) one station is talking with another station.
    b.) a special purpose button is pushed after a call is established. 
    c.) the station is calling another station in the network. 
    d.) CALL WAITING [C-12, 13] is being set up. 
    e.) the station is using VOICE CALL - D
    term [V-2D].
    f.) the ATTENDANT CONSOLE [A-3] indication shows an incoming call.
    8. MW for one station of the network can be controlled from the ATTENDANT CONSOLE [A-3] and any
    other station at the same time. The controlled station cannot identify the controlling party.
    9. The MW indication on the boss’ station appears as follows:
    10. The LCD on the secretary’s station displays the following messages:
    11. MW cannot be activated on a virtual line. The LCD displays MW REST, and the reorder tone is heard
    when activation from a virtual line is attempted.
    Note:
    The reorder tone is not heard while talking to the calling party.
    12. This feature can control the Call Indicator Lamp or MW display from the sub-line during:
    a.) conversation with the calling party.
    b.) special code dialing after replacing the handset or pressing the SPEAKER key.
    c.) ringback tone for station calling.
    d.) MUSIC ON HOLD [M-7] when the other party has pressed the HOLD key.
    e.) dialing of telephone number.
    Type of Station Set Message Waiting Indication
    Dterm Series E
    Status of Boss’ Station LCD Dterm Series E Type of Tone
    MESSAGE 
    WAITING 
    (already set)SETTING
    CANCELLING
    MESSAGE 
    WAITING (not 
    set)SETTINGCall Indicator 
    is ON
    MW
    (Time Display)
    MW                            BUSY
    (Time Display)
    MW
    (Time Display)                           CANCEL
    MW                               SET
    (Time Display) 
    						
    							NEAX2400 IMX Feature Programming Manual
    Page 92ND-70184 (E), Issue 3
    B-8 Boss - Secretary - Message Waiting Lamp Control
    Service Conditions (cont’d)
    f.) trunk origination or called-number dialing.
    g.) calls to or talking to Attendant.
    h.) THREE-WAY CALLING [T-2].
    i.) CONSULTATION HOLD - ALL CALLS [C-17].
    j.) calls by VOICE CALL - D
    term [V-2D].
    k.) Call Waiting ringback tone with Call Waiting set.
    l.) secretary calls to boss by BOSS-SECRETARY TRANSFER [B-11].
    13. MW can be cancelled for a station in the same module group using the MY Line during: 
    a.) conversation with the calling party.
    b.) ringback tone for station calling.
    c.) MUSIC ON HOLD [M-7] when the other party has pressed the HOLD key.
    d.) THREE-WAY CALLING [T-2].
    e.) CONSULTATION HOLD - ALL CALLS [C-17].
    f.) calls by VOICE CALL - D
    term [V-2D].
    g.) Call Waiting ringback tone with Call Waiting set.
    14. CALL WAITING [C-12, 13] set from any other station causes the MW Indication for the party setting the
    call waiting to go off.
    15. THREE-WAY CALLING [T-2] established by EXECUTIVE RIGHT-OF-WAY - D
    term [E-1D] causes
    the MW Indication connected to the interrupted party to go off when the interrupting party presses the MW
    CANCEL button. When using a soft key, press the MW OFF to cancel.
    16. FCCS link is not available for this feature.
    Interactions
    1. Use of the following features has no effect on this feature. BOSS-SECRETARY MW LAMP CONTROL
    can be set/cancelled to a station that has previously activated any of the following features:
    a.) DO NOT DISTURB - D
    term [D-21D]
    b.) CALL BACK - Dterm [C-1D] set to boss’ station
    c.) CALL BACK - Dterm [C-1D] set from boss’ station
    d.) CALL FORWARDING ALL CALLS - Dterm [C-5D] will not follow forwarding data
    e.) CALL FORWARDING DON’T ANSWER - Dterm [C-3D] will not follow forwarding data
    f.) CALL FORWARDING BUSY - Dterm [C-2D] will not follow forwarding data.
    2. When the boss’ line is answered by the secretary, the following services may be activated either by the
    secretary or by another station towards the secretary. These services will not interfere with the secretary’s
    ability to set/cancel MW.
    a.) PRIVACY - D
    term [P-14D]
    b.) CONSULTATION HOLD - ALL CALLS [C-17]
    c.) CALL WAITING - ORIGINATING [C-31] set to boss’ station
    d.) CALL WAITING - ORIGINATING [C-31] set from boss’ station
    e.) ATTENDANT CAMP ON WITH TONE INDICATION [A-1] set to boss’ station
    f.) THREE-WAY CALLING - D
    term [T-2D]
    g.) NON-EXCLUSIVE HOLD - Dterm [N-7D], EXCLUSIVE HOLD - Dterm [E-4D] or DUAL
    HOLD [D-32]. 
    						
    							NEAX2400 IMX Feature Programming Manual
    ND-70184 (E), Issue 3
    Page 93
    Boss - Secretary - Message Waiting Lamp Control B-8
    Programming
    STEP 1:AKYD - Assign to a programmable line/feature key a MW Lamp Set key; Type:Function:BOSS-
    SECRETARY MSG WAIT-SET [9] and a MW Lamp Cancel key; Type:Function:BOSS-
    SECRETARY MSG WAIT-CNCL [11].
    STEP 2:ADSL - Assign SN=4 (Communication in Progress) when operating Procedure 1, SN=2 (Originating)
    when operating Procedure 2. Assign FKY=9 (MW Lamp Set key; MWSET) and FKY=11 (MW Lamp
    Cancel key; MWOFF).
    This command is required only for assigning the function to each soft key.
    STEP 3:ASFC - Assign the stations a feature class that allows; SFI:74 (MW Called) and SFI:82 (MW Set). 
    						
    							NEAX2400 IMX Feature Programming Manual
    Page 94ND-70184 (E), Issue 3
    B-11 Boss - Secretary Transfer
    B-11 Boss - Secretary Transfer
    General Description
    This feature allows a secretary to voice-announce a call to a boss when the secretary answers a call to the boss line.
    Operating Procedure
    To transfer from Dterm to Dterm:
    1. Call terminates to Boss line. 
    2. Secretary answers the call on the sub-line of Secretarys D
    term. 
    3. Secretary presses the line key of answered call; Boss and Secretary talk by Voice Call. LCD displays:
    4. Boss answers the call. LCD displays:
    5.  Secretary hangs up; calling party talks to Boss. LCD displays:
    To transfer from Dterm to a single line telephone:
    1. Call terminates to Boss line.
    2. Secretary answers the call on the sub-line of Secretarys D
    term.
    3. Secretary presses the line key of the answered call. Boss station rings. LCD displays (Secretary): 
    4. Boss answers the call.
    5. Secretary hangs up; calling party talks to Boss.
    To cancel:
    1. Secretary presses the line key.
    2. Secretary talks to the calling party.
    Service Conditions
    1. Secretary must have boss My Line appearing on the Dterm in a multi-line operation.
    2. Secretary must have a D
    term for this operation. Boss may have a single line telephone.
    3. This service feature is only available when the secretary is talking on the boss My Line.ICM
    (Time Display)
    XXXX Boss/Secretary
    TRANSFER
    (Time Display)
    XXXX Secretary
    (Time Display)
    XXXX Calling Party
    TRANSFER
    (Time Display)
    XXXX 
    						
    							NEAX2400 IMX Feature Programming Manual
    ND-70184 (E), Issue 3
    Page 95
    Boss - Secretary Transfer B-11
    Service Conditions (cont’d)
    4. This feature must be allowed in CLASS OF SERVICE - INDIVIDUAL [C-15] via System Data
    programming.
    5. BOSS-SECRETARY TRANSFER [B-11] is denied if the secretary is connected to the ATTENDANT
    CONSOLE [A-3].
    6. If provided in the system, the held caller will hear MUSIC ON HOLD [M-7].
    7. The call is recorded in SMDR [S-10] for the boss station.
    8. This feature will override CALL FORWARDING - BUSY LINE [C-2] set for the boss, unless the boss’
    line is forwarded to the secretary.
    9. THREE-WAY CALLING [T-2] (Boss, Secretary and calling party) is not available.
    10. A BOSS-SECRETARY TRANSFER call cannot be picked up by CALL PICKUP [C-7, 30].
    11. Name Display service is not available when the secretary is calling the boss or when the secretary is talking
    to the boss.
    12. When the boss is using a D
    term, the boss must always press the line key in order to answer the call
    transferred from the secretary.
    13. FCCS link is not available for this feature.
    Programming
    STEP 1:ANPD - Reserve a number level for feature access. Assign for Normal (N), Hooking (H), and Busy
    (B). Assign NND in accordance with a predetermined numbering plan.
    STEP 2:ASFC - Assign station to receive Boss-Secretary Override a feature class that allows the following
    SFIs: 5, 6, 10, 11 and 51. Assign these SFIs as Data “1”.
    STEP 3:AKYD - Boss’ My line must be assigned as a sub-line on the secretary’s phone. 
    						
    							NEAX2400 IMX Feature Programming Manual
    Page 96ND-70184 (E), Issue 3
    B-12 Brokerage Hotline - Outside
    B-12  Brokerage Hotline - Outside
    General Description
    This feature provides a HOT LINE - OUTSIDE [H-9] function for a Dterm.
    Operating Procedure
    To access a BROKERAGE HOT LINE - OUTSIDE from a Dterm: 
    1. Lift the handset or press the SPEAKER key. 
    2. Press the sub-line key associated with a predetermined desired outside party. The destination station is
    automatically dialed; ringback tone is heard; the destination station answers.
    3. After completion of the conversation, hang up or press the SPEAKER key.
    To immediately make another BROKERAGE HOT LINE - OUTSIDE call:
    1. Press another sub-line button associated with another station without going on/off-hook. The RELEASE
    key on the Add-On Module can be used as the RELEASE key.
    2. A maximum of 39 BROKERAGE HOTLINES-OUTSIDE can be used to access distant destinations.
    Service Conditions
    1. One of the line keys of the Dterm must be assigned as the My Line.
    2. When a BROKERAGE HOT LINE - OUTSIDE call is made, the D
    term display shows the connected trunk
    number but does not show a SERVICE DISPLAY [S-25] for the BROKERAGE HOT LINE.
    3. The My Line of a D
    term cannot be assigned as a BROKERAGE HOT LINE - OUTSIDE.
    4. The virtual line of a single line station can be assigned as the hot line station.
    5. BROKERAGE HOT LINE - OUTSIDE uses SPEED CALLING - SYSTEM [S-3] memory. The total
    number of BROKERAGE HOT LINE - OUTSIDE destinations is limited by the capacity of the SPEED
    CALLING - SYSTEM [S-3].
    6. ATTENDANT CAMP-ON [A-1], CALL BACK [C-1], CALL WAITING [C-31], and EXECUTIVE
    RIGHT-OF-WAY [E-1] can be prohibited to the BROKERAGE HOT LINE - OUTSIDE connection
    through CLASS OF SERVICE - INDIVIDUAL [C-15].
    7. A hot line station user confronted with all trunks busy or all senders busy at the time of calling hears the
    reorder tone. No indication is shown on the users D
    term LCD.
    8. Outside connection when a user calls in BROKERAGE HOT LINE - OUTSIDE service is realized when
    trunk classification (DDD, TIE, CCSA) and the trunk number is indicated on the LCD indication.
    9. Outside connection when a user answers in BROKERAGE HOT LINE - OUTSIDE service is realized
    when time duration, trunk classification (DDD, TIE, CCSA) and the trunk number is indicated on the LCD
    indication.
    10. The Station Message Detail Recording (SMDR) is available for outgoing calls in the BROKERAGE HOT
    LINE - OUTSIDE service.
    11. A D
    term with an Add-On Module attached is used for applications requiring at least 15 but fewer than 39
    destinations. In this case, one of the line keys of the Dterm must be assigned as the My Line.
    12. An AC Adapter is required for the Add-On Module for the D
    term phones.
    13. This feature can be activated via FCCS.
    14. Only the station assigned a telephone number is available for the station assignment when activating this
    feature via FCCS. 
    						
    All NEC manuals Comments (0)