SYSTEM MESSAGES
This message displays when a B-level infinite loop failure occurs.
➀Information on Self-CPU Restart 
after detection of a clock fault
➁ Mate-CPU Restart Information
➂ B-level Infinite Loop
➃ Data to be Analyzed by NEC Engineers
See Chapter 5 for repair procedure.
0-F Memory Failure
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➀ ➁
➂ 
➃
4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
➃
7: XXXX XXXX XXXX XXXX 8:...

Page 92

CHAPTER 3 NDA-24307
Pag e 6 4
Issue 1
SYSTEM MESSAGES
This message displays when, in the CPU program processing, the counter value to check the normality of the
processing has become abnormal.
➀ Self-CPU Restart Information
➁ Mate-CPU Restart Information 
(FF H: not mounted)
➂
➃
 Data analyzed by NEC Engineers
See Chapter 5 for repair procedure.
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➀ ➁ ➂ ➃ ➃ ➃
4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
➃➃➃
7: XXXX...

Page 93

NDA-24307 CHAPTER 3
Page 65
Issue 1
SYSTEM MESSAGES
This message displays when a fault, such as the Clock down or C-level infinite loop error, has occurred.
➀ STBY-side CPU Fault Information
See Chapter 5 for repair procedure.
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b3 b2 b1 b0
Default Alarm:
SUP0-IMate CPU FailureDefault Grade:
3Grade...

Page 94

CHAPTER 3 NDA-24307
Pag e 6 6
Issue 1
SYSTEM MESSAGES
This message displays when the CPU detects abnormal interruption.
➀ Self-CPU Restart Information
➁ Mate-CPU Restart Information 
(FF H: not mounted)
➂
➃
 Data analyzed by NEC Engineers
See Chapter 5 for repair procedure.
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➀  ➁ ➂   ➃ ➃ ➃ ➃
4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
➃➃➃
7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000
➃➃
b7...

Page 95

NDA-24307 CHAPTER 3
Page 67
Issue 1
SYSTEM MESSAGES
This message displays when link information cannot be written into the switch memory of the TSW in both
systems.
➀TSW system in which a fault is 
detected
➁ Status at the time of fault detection
➂ Data analyzed by NEC Engineers
See Chapter 5 for repair procedure.
1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀  ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9:...

Page 96

CHAPTER 3 NDA-24307
Pag e 6 8
Issue 1
SYSTEM MESSAGES
This message displays when link information cannot be written into the switch memory of the TSW card in
one of the dual systems.
➀TSW system in which a fault is 
detected
➁ Status at the time of fault detection
➂ Data analyzed by NEC Engineers
See Chapter 5 for repair procedure.
1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀  ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000...

Page 97

NDA-24307 CHAPTER 3
Page 69
Issue 1
SYSTEM MESSAGES
This message displays when the link information cannot be written into the switch memory of the TSW in both
systems.
➀TSW system in which a fault is 
detected
➁ 
➂ Data analyzed by NEC Engineers
See Chapter 5 for repair procedure.
1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀  ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b0
b6 b0...

Page 98

CHAPTER 3 NDA-24307
Pag e 7 0
Issue 1
SYSTEM MESSAGES
This message displays when the link information cannot be written into the switch memory of the TSW card
in one of the dual systems.
➀TSW system in which a fault is 
detected
➁ Status at the time of fault detection
➂ Data analyzed by NEC Engineers
See Chapter 5 for repair procedure.
1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8:...

Page 99

NDA-24307 CHAPTER 3
Page 71
Issue 1
SYSTEM MESSAGES
This message displays when the system detects a clock failure, such as TSW internal clock down or Frame
Head down, in both systems.
➀TSW card in which a fault is 
detected
➁ Clock status of No. 0 TSW
➂ Clock status of No. 1 TSW
Note:Refer to the meaning of ➁.
See Chapter 5 for repair procedure.
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000...

Page 100

CHAPTER 3 NDA-24307
Pag e 7 2
Issue 1
SYSTEM MESSAGES
This message displays when the system detects a clock failure, such as TSW internal clock down or Frame
Head down in one of the dual systems.
➀TSW card in which a fault is 
detected
➁ Clock status of No. 0 TSW
➂ Clock status of No. 1 TSW
Note:Refer to the meaning of ➁.
See Chapter 5 for repair procedure.
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀  ➁➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7:...