Page 41

EXTERNALPAGING AND PAGE RELAYS
Using External Paging
The Auxiliary PCB has one External Paging audio output
and one associated control relay. You connect the audio out-
put to the audio input on customer-provided paging systems.
In some paging systems, you can use the control relay to
automatically turn the amplifier on and off. The control
relay is normally opened and closes whenever a user calls
the External Paging zone.
Installing External Paging and Page Relay (Figure 4-4)
CAUTION
Be sure the audio...

Page 42

EXTERNALPAGING AND PAGE RELAYS
4-6Figure 4-4  CONNECTING EXTERNAL PAGING/RELAY
Figure 4-5  CONNECTING EXTERNAL PAGING
One-Pair Cross-Connect
DDK 
Connector To External Page
audio output on 
Auxiliary PCB
25-Pair DDK
Installation CableC Block
Cross
Connect
BlockOutput to
paging
system
control
inputs
82400 - 10
One-Pair Cross-Connect
DDK 
Connector To Control Relay
on Auxiliary PCB
25-Pair DDK
Installation CableC Block
Cross
Connect
BlockOutput to
paging
system
control
inputs
82400 - 9
HDWRY1-Aa.QXD...

Page 43

EXTERNALPAGING AND PAGE RELAYS
4-7 Figure 4-6  CONNECTING CONTROL RELAYS TO THE
AUXILIARYPCB
82500 - 13
Auxiliary PCB
DH2 DH1 EXMOH SPK CTR RL2 RL1(DH2)(DH1)(SPK)
VR4VR3VR1
ARM (MOH)
EXT
INT
SW1
Amplifier Paging Speaker
HDWRY1-Aa.QXD  10/15/97 7:44 AM  Page 4-7 

Page 44

DOOR BOX
4-8
Using the Door Box
Each Auxiliary PCB supports two Door Boxes. In addition,
you can connect each circuitÕs control relay to an electric door
strike. This allows an extension user to remotely activate  the
door strike while talking to a visitor at the Door Box. The
control relays are normally open.
Installing a Door Box 
(Figure 4-7)
1. Locate an available 2-pin DDK connector in an auxiliary
(C) block.
2. For the DDK connector chosen, cross-connect the associated
wire pair from the C block to...

Page 45

DOOR BOX
4-9 Figure 4-7  CONNECTING A DOOR BOX
15
6 L
C
T
T
234LF
To Door Chime Box 1Rear view
To Door
Chime Box 221
22
23
24
* typical installation
RED-BRN
BRN-RED
RED-SLT
SLT-RED*
*
Misc Block
Holes for
mounting screws
920 - 159A
HDWRY1-Aa.QXD  10/15/97 7:44 AM  Page 4-9 

Page 46

DOOR BOX
4-10
Installing Door Strike Control Relays(Figure 4-8)
CAUTION
Be sure the requirements of the door strike are compatible
with the control relay output specifications of the system.
Contact Configuration: Normally open
MaximumLoad: 250 mA@ 24 VDC
Maximum Initial Contact Resistance: 50 mOhms
1.Locate an available 2-pin DDK connector in an auxiliary
(C) block.
2.For the DDK connector chosen, cross-connect the associ-
ated wire pair from the C block to the cross-connect
block.
3.Connect two leads...

Page 47

DOORBOX
4-11 Figure 4-8  CONNECTING TO THE DOOR STRIKE
Figure 4-9  CONNECTING DOOR BOX/DOOR STRIKE RELAYS TO
THE AUXILIARYPCB
82500 - 12
Auxiliary PCB
To Door Strike
Terminals
DH2 DH1 EXMOH SPK CTR RL2 RL1(DH2)(DH1)(SPK)
VR4VR3VR1
ARM (MOH)
EXT
INT
SW1
Door Box
One-Pair Cross-Connect
DDK 
Connector To Control Relay
on Auxiliary PCB
25-Pair DDK
Installation CableC Block
Cross
Connect
BlockOutput to
door strike
82400 - 8
HDWRY1-Aa.QXD  10/15/97 7:44 AM  Page 4-11 

Page 48

MUSIC SOURCES
4-12
Music on Hold
Music on Hold (MOH) provides music to callers on Hold.
The systemÕs default setting provides an internal (synthe-
sized) MOH music source, or a customer-provided music
source connected to the Auxiliary PCB can be used instead.
There are two jumpers that determine whether or not the
system will play Music on Hold.  The first jumper is located
on the CPU and is labeled SW2.  This jumper should be set
to the ON position.  If it is not, it overrides the setting of the
SW1...

Page 49

MUSIC SOURCES
4-13 Figure 4-10  CONNECTING MUSIC SOURCES
Figure 4-11  CONNECTING TO THE AUXILIARY PCB
82500 - 11
External MOH Source Auxiliary PCB
The relay contacts
RL1 and RL2 can be
used as a MOH
device control. The
remote control terminal
on the device must be
connected to these
contacts (see
PROGRAM 56).
DH2 DH1 EXMOH SPK CTR RL2 RL1(DH2)(DH1)(SPK)
VR4VR3VR1
ARM (MOH)
EXT
INT
SW1
82500 - 3
One-Pair Cross-Connect
To MOH on
Auxiliary PCBTo
music
source
DDK
Connector25-Pair DDK
Installation CableC...

Page 50

CALLER ID
4-14
Using the Caller ID Feature
Each Auxiliary PCB supports the use of Caller ID on the
three CO lines in the system.  Caller ID allows a display key-
set to show an incoming callerÕs telephone number and/or
name with the time and date on the phoneÕs display.  The
callerÕs information can be checked before answering an
incoming call.  The information received by the system
depends upon the capabilities of your local telco.
Connecting Caller ID (Figure 4-12)
1.With two 2-pin DDK connectors (one...