    							SCHEMATIC DIAGRAM 3/4
    TESTR02       1kR01
    10k
    R32
    150k
    4.096 MHz
    (47pF X 2) 
    R41
    1k Q03
    C143XKTXR44
    1kC16
    0.01µ
    R37
    10k 
    12
    R38JX1
    C15
    0.01µR43
    R79
    10k 
    X01
    CN-ION4
    3
    2
    1
    C37
    0.01µQ05
    C2412KTXC10
    0.1µ
    16V
    JP3
    R49     1k
    JP4
    C17
    3300µ
    35VC14
    470µ
    25VC11
    100µ
    16V
    IC03
    G I
    5V 12VI
    G IC04
    DB01T01
    5
    8
    13 2REGULATOR
    REGULATOR
    +~
    ~OO
    TEMPERATURE
    FUSE
    TO OUTDOOR
    RY-PWR
    AC-WHT T 2A L 250VFUSE
    P L
    RED
    BLU
    RY-HOTCT01
    R35
    D14D13
    C09C06
    HOT
    FM
    SSR02
    e c
    b Q08 R61
    10k
    R67
    R62
    C36
    Q07
    R64
    6.2k
    D01
    R63
    6.2k
    c
    b
    eC32
    0.01µ
    C31
    0.01µ
    CN-FM
    5 4 3
    2 1
    CN-FB
    R36
    1k
    3 2
    1
    FAN MOTOR
    CR01
    CR02
    +R34
    10k
    R26
    1k
    C03
    0.047µ
    C-FM
    1.5µZNR01
    SSR01CR03
    L01
    125µH
    C19
    0.047µ
    C12
    0.1µ
    16V
    C21
    10µ
    50V
    c
    b
    e
    R66R48
    R29
    1.6k 
    R03      1.3k 
    4.7k 
    10k R57     12k 
    C07
    0.1µ
    16V
    D16
    R47     12k D15
    R50
    100k
    C18
    0.1µ
    16V
    c
    b
    eQ06
    C2412KTXc
    b
    e
    R54
    6.2k R51
    10k
    R53
    10kR52
    6.2k
    +
    Z01
    7.5V
    ec
    b
    SSR01 Q02
    C143XKTX
    4.7k 
    10k 
    ec
    b
    SSR02
    3
    4
    1
    2
    81
    CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 
    						
    							SCHEMATIC DIAGRAM 4/4
    EH-4P
    4
    3
    21
    F1
    CH1
    VIN
    GND
    ERR
    C2 C1Q1
    Q2Q4
    Q5
    R2
    c
    eb
    4.7k
    10k
    e bcC3 R4
    R3
    R5
    D2
    Z01D4
    c
    eb
    C8
    D1D3
    R14 R13
    R9
    R15
    R10R102-4.2kV
    R101
    HV CN2
    R12 C5
    D5
    C6 Z02
    c
    eb
    R6
    T1D101
    D102
    C101
    C7
    GNDCN3
    HIGH VOLTAGE IONIZER
    CU-A12DKD CU-A7DKD / CU-A9DKD
    TO INDOOR
    3
    4
    1
    2
    COIL REVERSING
    VA LV EELECTROLYTIC
     CAPACITOR
    BL/B
    BL
    BLFA N
    MOTOR
    CAPACITOR
    CAPACITOR
    COMPRESSOR
    TRSBL
    BL
    33 1 42 8
    28
    67
    5 67
    BL/B
    MAGNETIC RELAY
    BL
    GRGR
    GRB
    BB
    R R
    OY
    B
    B B
    R BBRMAGNETIC RELAY 
    TO INDOOR
    3
    4
    1
    2
    COIL REVERSING
    VA LV EELECTROLYTIC
     CAPACITOR
    BL/B
    BLBLFA N
    MOTOR
    CAPACITOR
    CAPACITOR
    OVER LOAD
    PROTECTOR
    COMPRESSOR
    TRSBL
    BL
    3 28
    67
    BL/BMAGNETIC RELAY
    BL
    GR
    GR YY
    B
    B B
    R RB B
    RBR
    FM
    1
    A9DK
    1A7DK
    4
    82
    CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 
    						
    							83
    CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 
    						
    							How to use electronic circuit diagram
    TIMER TABLE
    Test Mode
    NameTime(When test pointRemarks
    Short-circuited)
    Real Timer1 hr.1 min.
    10 min.10 sec.
    1 min.1 sec.
    Time Delay Safety Control2 min. 58 sec.0 sec.
    Forced Operation60 sec.0 sec.
    Time Save Control7 min.4.2 sec.
    Anti-Freezing4 min.0 sec.
    Auto Mode Judgement25 sec.0 sec.
    Soft DryOFF6 min.36 sec.
    ON10 min.60 sec.Soft Dry: 10 min. operation
    Deodorizing Control
    Cooling40 sec.4 sec.
    70 sec.7 sec.
    20 sec.2 sec.
    180 sec.18 sec.
    Soft Dry40 sec.4 sec.
    360 sec.36 sec.
    Comp. Reverse Rotation Detection5 min.30 sec.Comp. ON 5 min. and above
    2 min.0 sec.
    Comp./ FanMotor DelayTimer1.6 sec.0 sec.
    Powerful Mode Operation15 min.15 sec.
    Random Auto Restart Control0 ~ 62 sec.0 ~ 6.2 sec.
    TRS Recovery Detection12 min.72 sec.
    6 min.36 sec.
    3 min.18 sec.
    1 min.6 sec.
    Time Save Control (Heating)30 min.3 sec.
    4 Way Valve Control (Delay)5 min.30 sec.
    Deice Operation Occurs60 min.6 sec.60 min. after previous deice
    4 min.24 sec.Continuously 4min. Comp. ON
    50 sec.0 sec.TRS ON continuouslyfor 50 sec. check
    Overload Deice Timer1 min.6 sec.Comp. ON continuouslyfor 1 min. check
    Deice End12 min.72 sec.Max. Operation time
    30 sec.3 sec.30 sec. Comp. OFF after deice
    10 sec.1 sec.4-Way Valve ON 10 sec. later after deice
    Deice Operation (Extend)60 sec.0 sec.
    120 sec.0 sec.
    180 sec.0 sec.
    Hotstart Finish30 sec.0 sec.
    84
    CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 
    						
    							19.2. Remote Control
    85
    CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 
    						
    							19.3. Print Pattern
    Indoor Unit Printed Circuit Board
    BOTTOM VIEW
    86
    CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 
    						
    							TOP VIEW
    87
    CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 
    						
    							19.4. Print Pattern
    Indicator & Receiver Printed Circuit Board
    BOTTOM VIEW
    TOP VIEW
    88
    CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /