    12.6. Indoor Fan Speed Control
    • Indoor Fan Speed can be set using remote control.
    12.6.1. Fan Speed Rotation Chart
    12.6.2. Automatic Fan Speed Control
    • When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table.
    - Fan speed rotates in the range of Hi, Me and Lo-.
    - Deodorizing Control will be activated.
    Fan Speed (rpm) CS-A7GKD CS-A9GKD CS-A12GKD
    S Hi 1190 1300 1320
    Hi 1030 1210 1300
    Me 920 1000 1120
    H Lo 840 890 860
    C Lo 780 830 800
    Lo- 750 780 750
    S Lo 700 750 700
    SS Lo 300 300 300
    Q S Hi 1090 1200 1220
    Q Hi 930 1110 1200
    Q Me 820 900 1020
    Q H Lo 770 790 810
    Q Lo 680 730 700 
    						
    							42 • Auto Fan Speed during cooling operation:
    1. Indoor fan will rotate alternately between off and on as shown in below diagram.
    2. At the beginning of each compressor start operation, indoor fan will increase fan speed gradually for deodorizing purpose.
    3. For the first time the compressor operate, indoor fan will be switched to Hi fan speed from Lo- after 70 seconds from the
    start of compressor. This cause the room temperature to achieve the setting temperature quickly.
    4. During compressor stop, indoor fan will operate at Lo- for the beginning 3 minutes to prevent higher volume of refrigerant
    in liquid form returning to the compressor.
    5. For the resume of compressor operation, indoor fan will operate at Me fan speed to provide comfort and lesser noise
    environment, after 70 seconds from the restart of compressor.
    • Auto Fan Speed during Soft Dry operation:
    1. Indoor fan will rotate alternately between off and Lo-.
    2. At the beginning of each compressor start operation, indoor fan will increase fan speed gradually for deodorizing purpose.
    3. When compressor at turn off condition for 6 minutes, indoor fan will start fan speed at Lo- to circulate the air in the room.
    This is to obtain the actual reading of intake air temperature. 
    						
    							43 • Auto Fan Speed during Heating operation.
    1. Indoor fan will rotate in the range of SLo → Me according to the heat exchanger temperature.
    12.6.3. Manual Fan Speed Control
    • Manual fan speed adjustment can be carried out by using the Fan Speed selection button at the remote control.
    • There are 3 types of fan speed settings: Lo, Me, Hi.
    12.7. Outdoor Fan Speed Control
    •There is only one speed for outdoor fan motor.
    • When the air conditioner is turned on, the compressor and the outdoor fan will operate simultaneously.
    • Likewise, both compressor and outdoor fan will stop at the same time if the unit is turned off.
    12.8. Vertical Airflow Direction Control
    12.8.1. Auto Control
    • When the vertical airflow direction is set to Auto using the
    remote control, the louver swings up and down as shown in
    the diagram.
    • When stop operation using the remote control, the discharge
    vent is reset, and stop at the closing position.
    • During Cooling operation or Soft Dry operation, indoor fan
    motor may stop to rotate at certain periods. At that condition,
    the louver will stop swinging and rest at the upper limit. 
    						
    							44 (Heating Operation condition)
    • When the piping air temperature reaches 38°C, the louver is
    changed from upper to lower limit. When the piping air
    temperature falls to 35°C, the louver is changed from lower
    to upper limit.Heating Operation
    12.8.2. Manual Control
    • When the vertical airflow direction is set to Manual using the remote control, the automatic airflow is released and the airflow
    direction louver move up and down in the range shown in the diagram.
    • The louver can be adjusted by pressing the button to the desired louver position.
    • When stop operation using the remote control, the discharge vent is reset, and stop at the closing position.
    • During Anti-dew condensation prevention, Airflow Direction Manual control angle change from 10°, 15°, 20°, 26°, 32° to 22°, 24°,
    26°, 28°, 30° under Cooling and Soft Dry operation mode.
    Cooling and Soft Dry Operation Heating Operation
    12.9. Horizontal Airflow Direction Control
    • The horizontal airflow direction louvers can be adjusted manually by hand.
    12.10. Powerful Operation
    •The Powerful operation is to achieve the setting temperature quickly.
    (Cooling and Soft Dry Operation condition)
    • When Powerful operation is set, the setting temperature will be automatically decreased 3°C internally against the present
    setting temperature (Lower temperature limit: 16°C).
    • This operation automatically will be running under SHi fan Speed (Cooling).
    • Vertical Airflow Direction:-
    - In “Manual” setting, the vane will automatically shift down 10° lower than previous setting.
    - In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
    (Heating Operation condition)
    • When Powerful operation is set, the setting temperature will be automatically increased 3°C against the present setting
    temperature (Higher temperature: 30°C). 
    						
    							45 • The Fan Speed will shift as shown below:
    • Vertical Airflow Direction:-
    - In “Manual” setting, the vane will automatically shift down 5° lower than previous setting.
    - In “Auto” setting, the vane will automatically shift between upper and lower limit depending on the intake air temperature as
    Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be shifted 5° downward.
    • Powerful operation stops when:-
    - Powerful operation has operate for 15 minutes.
    - Powerful button is pressed again.
    - Quiet button is pressed.
    - Stopped by OFF/ON operation button.
    - Timer OFF activates.
    -Operation mode is changed. 
    						
    							46
    12.11. Quiet Operation
    (For Cooling Operation or cooling region of Soft Dry Operation)
    •To provide quiet cooling operation condition compare to normal operation.
    • Once the Quiet Mode is set at the remote control, the Quiet Mode LED illuminated. The sound level will reduce around 2 dB(A)
    for Lo fan speed or 3 dB(A) for Hi/Me fan speed against the present operation sound level.
    • Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1hr 30 min (1hr QLo, 30 min QLo + 50
    rpm). After that, it goes back to Lo cool (However Quiet LED remains on).
    • Manual Airflow Direction:-
    - RPM control during Lo cool
    - RPM control during Hi & Me cool
    • Auto Fan Speed:-
    • Quiet operation stops when:-
    - Quiet button is pressed again.
    - Stopped by OFF/ON operation button.
    - Timer OFF activates.
    - Operation mode button is changed. 
    						
    							47 (Heating Operation condition)
    • When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates. The sound level will reduce either around 2 dB
    (Lo) or 3 dB (Hi, Me), against the present sound level operation.
    • Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
    • Manual Fan Speed:-
    - Rpm control during Lo, Me & Hi Cool
    • Auto Fan Speed:-
    - Rpm control depends on the piping air temperature sensor of Indoor heat exchanger
    • Quiet operation stops when:-
    - Quiet button is pressed again.
    - Powerful button is pressed.
    - Stopped by OFF/ON operation button.
    - Timer OFF activates. 
    						
    							48
    12.12. Timer Control
    12.12.1. ON Timer
    • When the ON Timer is set by using the remote control, the unit will start to operate slightly before the set time, so that the room
    • will reach nearly to the set temperature by the set time.
    • For Cooling and Soft Dry operation, the operation will start 15 minutes before the set time.
    • For Automatic operation, the indoor fan will operate at SLo speed for 20 seconds, 30 minutes before the set time to detect the
    intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
    12.12.2. OFF Timer
    • When the OFF Timer is set by using the remote control, the unit will stop operate according to the desired setting.
    Notes:
    1. By pressing ON/OFF operation button, the ON Timer or OFF Timer setting will not be cancelled.
    2. To cancel the previous timer setting, press CANCEL button.
    3. To activate the previous timer setting, press SET button.
    4. If main power supply is switched off, the Timer setting will be cancelled.
    12.13. Random Auto Restart Control
    • If there is a power failure during operation, the air conditioner will automatically restart after 3 to 4 minutes when the power is
    resumed.
    • It will start with previous operation mode and airflow direction.
    • If there are more than one air conditioner unit in operation and power failure occur, restart time for each unit to operate will be
    decided randomly using 4 parameters:- intake air temperature, setting temperature, fan speed and air swing louver position.
    • This Random Auto Restart Control is not available when Timer is set.
    12.14. Remote Control Signal Receiving Sound
    • Short beep sound will be heard when:-
    - enable initial Patrol Operation.
    • Long beep sound will be heard for others setting. 
    						
    							49
    12.15. Patrol Operation
    1. Purpose
    To monitor air dirtiness level by using gas sensor and activates e-ion operation whenever air is dirty.
    2. Control Condition
    a. Patrol operation start condition
    • When the unit operation is started with “OFF/ON” button.
    • When the unit stops, “Patrol” button is pressed, Patrol individual operation will start.
    • During cooling only operation, “Patrol” button is pressed.
    b. Patrol operation stop condition
    When any of the following condition is fulfilled:
    • When “OFF/ON” button is pressed.
    • During any operation with Patrol, Patrol button is pressed again.
    • When “e-ion” button is pressed.
    • When OFF Timer activates.
    c. Patrol operation disable
    • To disable the Patrol Operation during unit start (default) with “OFF/ON” button, press “Patrol” button and hold for 5
    seconds, then release.
    • To disable the Patrol Operation, press “Patrol” button and hold for 15 seconds, then release. 
    						
    							50 3. Control Content
    a. Gas Sensor Control
    • First 2 minutes from Patrol function activates is stabilization time, during stabilization time, no air dirtiness level is
    monitored. The Air Dirtiness level is set to level 2.
    • After that, gas sensor starts to record the resistance value at fixed interval. Higher resistance value indicates cleaner air.
    • The air dirtiness level is monitored by comparing the current resistance value with maximum resistance value from time to
    time to get the Air Dirtiness Value.
    • There are 3 air dirtiness level, based on the Air Dirtiness Value:
    - Air Dirtiness level 0: Clean
    - Air Dirtiness level 1: Moderate
    - Air Dirtiness level 2: Contaminated
    - Dirtiness level sensitivity adjustment.
    It is possible to change the gas sensor sensitivity, where the Threshold value (G1 ~ G4) will be shifted accordingly:
    a. Press and release “SET” button.
    b. Press “Timer increment” / “Timer decrement” button to select sensitivity. (Low <
    –> Standard (Default)  High)
    c. Confirm setting by pressing “Timer Set” button. LCD returned to original display after 2 seconds.
    d. LCD returned to original display if remote control does not operate for 30 seconds.
    b. e-ion Control
    • When dirtiness level is 1 or 2, e-ion operation starts.
    • If dirtiness level improves from level 2 to level 1, the unit carries out level change after 60 seconds.
    • When dirtiness level returns to level 0 continuously for 10 minutes or more, e-ion operation stops.
    Dirtiness Level Shift
    • For Auto Fan Speed, the fan speed increased based on dirtiness level: 
    						