Home > Panasonic > Air Conditioner > Panasonic Cs A9dka Cu A9dka Cs A12dka Cu A12dka Repair Manual

Panasonic Cs A9dka Cu A9dka Cs A12dka Cu A12dka Repair Manual

Here you can view all the pages of manual Panasonic Cs A9dka Cu A9dka Cs A12dka Cu A12dka Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.

Page 11

4.2. Outdoor Unit
4.2.1. CU-A9DKA
4.2.2. CU-A12DKA
11
CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA / 

Page 12

5 Refrigeration Cycle Diagram
12
CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA / 

Page 13

6 Block Diagram
13
CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA / 

Page 14

14
CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA / 

Page 15

7 Wiring Diagram
15
CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA / 

Page 16

16
CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA / 

Page 17

8 Operation Details
8.1. Heating Operation
 • Heating operation can be set using remote control.
 • This operation is applied to warm the room temperature reaches the setting temperature set on the remote control.
 • The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C
to 30°C.
 • During heating operation, the compressor will stoprunning and restart as shown in below figure.
8.1.1. Heating Operation Time Diagram
17
CS-A9DKACU-A9DKA /...

Page 18

8.2. Cooling Operation
 • Cooling operation can be set using remote control.
 • This operation is applied to cool down the room temperature reaches the setting temperature set on the remote control.
 • The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C
to 30°C.
 • During cooling operation, the compressor will stoprunning and restart as shown in below figure.
8.2.1. Cooling Operation Time Diagram
18
CS-A9DKACU-A9DKA / CS-A12D KA...

Page 19

8.3.1. Soft Dry Operation Time Diagram
8.3. Soft Dry Operation
 • Soft Dry operation can be set using remote control.
 • Soft Dry operation is applied to dehumidify and to perform a gentle cooling to the room.
 • This operation starts when the intake air temperature sensor reaches the setting temperature on the remote control.
 • W hen operation begins, Soft Dry will be switched “ON” for a maximum 10 minutes, then Soft Dry operation will be turned “OFF”
for a minimum 6 minutes. After that, the Soft Dry...

Page 20

8.4. Automatic Operation
 • Automatic operation can be set using remote control.
 • This operation starts to operate with indoor fan at SLo speed for 25 seconds to judge the intake air temperature.
 • After judged the temperature, the operation mode is determined by referring to the below standard.
 • Then, the unit start to operate at determined operation mode, until it is switched off using remote control, with the setting
temperature as shown in below table.
 • Operation mode will be determine again...
Start reading Panasonic Cs A9dka Cu A9dka Cs A12dka Cu A12dka Repair Manual

Related Manuals for Panasonic Cs A9dka Cu A9dka Cs A12dka Cu A12dka Repair Manual

All Panasonic manuals