Home > Panasonic > Air Conditioner > Panasonic Cs A9dkh Cu A9dkh Cs A12dkh Cu A12dkh Repair Manual

Panasonic Cs A9dkh Cu A9dkh Cs A12dkh Cu A12dkh Repair Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Cs A9dkh Cu A9dkh Cs A12dkh Cu A12dkh Repair Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							41
    CS-A9DKH CU-A9DKH / CS-A12D KH CU-A12D KH / 
    						
    							42
    CS-A9DKH CU-A9DKH / CS-A12D KH CU-A12D KH / 
    						
    							10 Installation Instructions
    Required tools forInstallationWorks
    1.Philips screw driver5.Spanner9.Gas leak detector13.Multimeter
    2.Level gauge6.Pipe cutter10.Measuring tape14.Torque wrench
    18 N.m (1.8 kgf.m)
    42 N.m (4.2 kgf.m)
    55 N.m (5.5 kgf.m)
    3.Electric drill, hole core drill
    (ø70 mm)7.Reamer11.Thermometer15.Vacuum pump
    4.Hexagonal wrench (4 mm)8.Knife12.Megameter16.Gauge manifo ld
    10.1. Safety Precautions
     • Read the following “SAFETY PRECAUTIONS” carefully before installation.
     • Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit
    for the model to be installed.
     • The caution items stated here must be followed because theseimportant contents are related tosafety. The meaningof each
    indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the
    seriousness is classified bythe following indications.
    This indication shows the possibility of causing death or serious injury.
    This indication shows the possibility of causing injury or damage to properties only.
    The items to be followed are classified by the symbols:
    Symbol with background white denotesitem that is PROHIBITED from doing.
     • Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and
    maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
    1.Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire.
    2.Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire.
    3.Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or
    electrical shock.
    4.Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly
    done, the set will drop and cause injury.
    5.For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single
    outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
    6.Use the specified cable (1.5 mm2) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no
    external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
    7.Wirerouting must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will
    cause heat-up at connection point of terminal, fire or electrical shock.
    8.Whencarrying out piping connection, take care notto let air substances other than the specified refrigerant go into refrigeration cycle.
    Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury.
    9.Do not damage or use unspecified power supply cord.Otherwise, it will cause fire or electrical shock.
    10.Do not modify the length of thepower supply cord oruse of the extension cord, and do not share the single outlet with
    other electrical applian ces. Otherwise, it will cause fire or electrical shock.
    43
    CS-A9DKH CU-A9DKH / CS-A12D KH CU-A12D KH / 
    						
    							1.The equipment must be earthed. It may cause electrical shock if grounding is not perfect.
    2.Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at
    surrounding of the unit, it may cause fire.
    3.Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
    furniture.
    1.Selection of the installation location.
    Select a installation location which is rigid and strong enough to support or hold the unit, and select alocation for easy maintenance.
    2.Power supply connectionto the room air conditioner.
    Connect the power supply cordof the room air conditioner to the mains using one of the following method.
    Power supply point shall be theplace where there is ease for access for the power disconnection in case of emergency.
    In some countries, permanent connection of this roomair conditioner to thepower supply is prohibited.
     1. Power supply connection to the receptacle using a power plug.
    Use an approved 15A/16A power plug with earth pin for the connection to the socket.
     2. Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for the permanent
    connection. It must be a double pole switch with a minimum 3 mm contact gap.
    3.Do not release refrigerant.
    Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the
    liquid refrigerant, it may cause frostbite.
    4.Installation work.
    It may need two people to carry out the installation work.
    5.Do not install this applian ce in a laundry room or other location where water may drip from the ceiling, etc.
    44
    CS-A9DKH CU-A9DKH / CS-A12D KH CU-A12D KH / 
    						
    							Applicable piping kit
    CZ-3F5, 7AEN (C7DK, C9DK, A7DK, A9DK, RS-C7DK, RS-
    C9DK)
    CZ-4F5,7, 10AN (C12DK, A12DK)
    10.3. Select the best location
    INDOOR UNIT
     • There should not be any heat source or steam near the
    unit.
     • There should not be any obstacles blocking the air
    circulation.
     • A place where air circulation in the room is good.
     • A place where drainage can be easily done.
     • A place where noise prevention is taken into
    consideration.
     • Do not install the unit near the doorway.
     • Ensure the spaces indicated by arrows from the wall,
    ceiling, fence or other obstacles.
     • Recommended installation height for indoor unit shall be
    at least 2.3 m.
    OUTDOOR UNIT
     • If an awning is built over the unit to prevent direct
    sunlight or rain, be careful that heat radiation from the
    condenser is not obstructed.
     • There should not be any animal or plant which could be
    affected by hot air discharged.
     • Keep the spaces indicated by arrows from wall, ceiling,
    fence or other obstacles.
     • Do not place any obstacles which may cause a short
    circuit of the discharged air.
     • If piping length is over the common length, additional
    refrigerant should be added as shown in the table.
    10.4. Indoor/Outdoor Unit
    Installation Diagram
     • This illustration isfor explanationpurposesonly.
    The indoor unit will actually face a differentway.
    10.2. Attached accessories
    45
    CS-A9DKH CU-A9DKH / CS-A12D KH CU-A12D KH / 
    						
    							10.5.1. SELECT THE BEST LOCATION
    (Refer to “Select the best location”
    section)
    10.5.2. HOW TO FIX INSTALLATION
    PLATE
    The mounting wall is strong and solid enough to prevent it from
    the vibration.
    The centre of installation plate should be at more than 450 mm
    at right and left of the wall.
    The distance from installation plate edge to ceiling should more
    than 67 mm.
    From installation plate left edge to unit’s left side is 74 mm.
    From installation plate right edge to unit’s right is 94 mm.
    :
    :
    :For left side piping, piping connection for liquid should be
    about 15 mm from this line.
    For left side piping, piping connection for gas should be
    about 45 mm from this line.
    For left side piping, piping connecting cable should be
    about 800 mm from this line.
     1. Mount the installation plate on the wall with 5 screws or
    more.
    (If mounting the unit on the concrete wall consider using
    anchor bolts.)
     • Always mountthe installation plate horizontally by
    aligning the marking-off line with the thread and using a
    level gauge.
     2. Drill the piping plate hole with ø70 mm hole-core drill.
     • Line according to the arrows marked on the lower left
    and right side of the installation plate. The meeting point
    of the extended line is the centre of the hole. Another
    method is by putting measuring tape at position as
    shown in the diagram above. The hole centre is
    obtained by measuring thedistance namely 150 mm
    and 125 mm for left and right hole respectively.
     • Drill the piping hole at either the right or the left and the
    hole should be slightly slanted to the outdoor side.
    10.5.3. TO DRILL A HOLE IN THE WALL
    AND INSTALL A SLEEVE OF
    PIPING
     1. Insert the piping sleeve to the hole.
     2. Fix the bushing to the sleeve.
     3. Cut the sleeve until it extrudes about 15 mm from the wall.
    CautionWhen the wall ishollow, please be sure to use the
    sleeve for tubeass’y to prevent dangers caused by
    mice biting the connecting cable.
     4. Finish by sealing the sleeve with putty or caulking
    compound at the final stage.
    10.5.4. INDOOR UNIT INSTALLATION
     1. For the right rear piping
     2. For the right and right bottom piping
    10.5. Indoor unit
    46
    CS-A9DKH CU-A9DKH / CS-A12D KH CU-A12D KH / 
    						
    							 3. For the embedded piping
    (This can be used for left rear piping & left bottom piping also.)
    47
    CS-A9DKH CU-A9DKH / CS-A12D KH CU-A12D KH / 
    						
    							10.5.5. CONNECT THE CABLE TO THE
    INDOOR UNIT
     1. The inside and outside connecting cable can be connected
    without removing the front grille.
     2. Connecting cable between indoor unit and outdoor unit
    shall be approved polychloroprene sheathed 3 (C7DK,
    C9DK, C12DK, RS-C7DK, RS-C9DK, RS-C12DK) or 5
    (A7DK, A9DK, A12DK) × 1.5 mm
    2flexible cord, type
    designation 245 IEC 57 or heavier cord.
     • Ensure the color of wires of outdoor unit and the
    terminal Nos. are the same to the indoor’s respectively.
     • Earth lead wire shall be longer than the other lead wires
    as shown in the figure forthe electrical safetyin case of
    the slipping out of the cord from the anchorage.
     • Secure the cable onto the control board with the holder
    (clamper).
    INSTALLATION OFSUPER ALLERU-BUSTER FILTER
     1. Open the front panel.
     2. Remove the air filters.
     3. Remove Supersonic air purifying device.
    Open the Supersonic air purifyingdevice frame.
    Insert the super alleru-buster filter and close the Supersonic
    air purifying device frame as shown in illustration at right.
    HOW TO TAKE OUT FRONT GRILLE
    Please follow the steps below to take out front grille if
    necessary such as when servicing.
     1. Open the intake grille and remove the screw at the front of
    the front grille.
     2. Set the vertical airflow direction louver to the horizontal
    position.
    48
    CS-A9DKH CU-A9DKH / CS-A12D KH CU-A12D KH / 
    						
    							 3. Slide down the 2 caps on the front grille as shown in the
    illustration at right, and then remove the 2 mounting screws.
    Pull the lower section of the front grille towards you to
    remove the front grille.
    When reinstalling the front grille, first set the vertical
    airflow direction louver to the horizontal position and
    then carry out above steps 2 -3 in the reverse order.
    AUTO SWITCH OPERATION
    The below operations will be performed by pressing the
    “AUTO” switch.
     1. AUTO OPERATION MODE
    The Auto operation will be activated immediately once the
    Auto Switch is pressed.
     2. TEST RUN OPERATION (FOR PUMP DOWN/SERV ICING
    PURPOSE)
    The Test Run operation will be activated if the Auto Switch
    is pressed continuously for more than 5 sec. to below 10
    sec. A “pep” sound will occur at the fifth sec., in order to
    identify the starting ofTest Run operation
     3. REMOTE CONTROLLER RECEIVING SOUND ON/OFF
    The ON/OFF of Remote Controller receiving sound can be
    change over by the following steps:
    a) Release the Auto Switch after Test Run operation is
    activated.
    b) Then, within 20 sec. after (a), press Auto Switch for more
    than 5 sec..A “beep” “beep” sound will occur at the fifth
    sec., then release the Auto Switch.
    c) Within 20 sec. after (b), press Auto Switch again.
    Everytime Auto Switch is pressed (within 20 sec. interval),
    remote controller receiving soundstatus will be reversed
    between ON and OFF.
    Long “beep” sound indicates that remote controller
    receiving sound is OFF.
    Short “beep” sound indicates that remote controller
    receiving sound is ON.
    10.6. Outdoor unit
    10.6.1. SELECT THE BEST LOCATION
    (Refer to “Select the best location”
    section)
    10.6.2. INSTALL THE OUTDOOR UNIT
     • After selecting the best location, start installation according
    to Indoor/Outdoor Unit Installation Diagram.
     1. Fix the unit on concreteor rigid frame firmly and horizontally
    by bolt nut. (ø10 mm).
     2. When installing at roof, please consider strong wind and
    earthquake. Please fasten theinstallation standfirmly with
    bolt or nails.
    10.6.3. CONNECTING THE PIPING
    Connecting The Piping To Indoor Unit
    Please make flare after inserting flare nut (locate at joint portion
    of tube assembly) onto the copper pipe. (In case of using long
    piping)
    Connect the piping
     • Align the center of piping and sufficiently tighten the flare
    nut with fingers.
     • Further tighten the flare nut with torque wrench in specified
    torque as stated in the table.
    MODELPiping size (Torque)
    GasLiquid
    C7DK, C9DK, A7DK, A9DK,
    RS-C7DK, RS-C9DK3/8” (42 N.m)1/4” (18 N.m)
    C12DK, A12DK, RS-C12DK1/2” (55 N.m)1/4” (18 N.m)
    Connecting The Piping To Outdoor Unit
    Decide piping length and then cut by using pipe cutter. Remove
    49
    CS-A9DKH CU-A9DKH / CS-A12D KH CU-A12D KH / 
    						
    							burrs from cut edge. Make flare after inserting the flare nut
    (located at valve) onto the copper pipe.
    Align center of piping to valves and then tighten with torque
    wrench to the specified torque as stated in the table.
    CUTTING AND FLARING THE PIPING
     1. Please cut using pipe cutter and then remove the burrs.
     2. Remove the burrs by using reamer. If burrs is not
    removed, gas leakage may be caused.
    Turn the piping end down to avoid the metal powder
    entering the pipe.
     3. Please make flare after inserting the flare nut onto the
    copper pipes.
    (1)*
    *Connect the manifo ld gauge to the service port of 3-way
    valve.
    Measure the pressure.(2)*
    *Keep it for 5-10 minutes.
    Ensure that the pressure indicated on the gauge is the
    same as that of measured during the first time.
    10.6.4. AIR PURGING OF THE PIPING AND INDOOR UNIT
    The remaining air in the Refrigeration cycle which contains moisture may cause malfunction on the compressor.
     1. Remove the caps fromthe 2-way and3-wayvalves.
     2. Remove the service-portcap from the3-wayvalves.
     3. To open the valve, turn the valvestem of 2-wayvalve counter-clockwise approx. 90° and hold it there for ten seconds, then
    close it.
     4. Check gas-leakage of the connecting portion of the pipings.
    For the left pipings, refer to item 4(A).
     5. To open2-wayvalve again, turn the valve stem counter-clockwise until it stops.
    4(A). Checking gas leakage for the left piping.
    50
    CS-A9DKH CU-A9DKH / CS-A12D KH CU-A12D KH / 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Cs A9dkh Cu A9dkh Cs A12dkh Cu A12dkh Repair Manual