Home > Panasonic > Air Conditioner > Panasonic Cs E719k Cs E919 Kcs E1219k Repair Manual

Panasonic Cs E719k Cs E919 Kcs E1219k Repair Manual

Here you can view all the pages of manual Panasonic Cs E719k Cs E919 Kcs E1219k Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.

Page 1

 1 Features 2
 2 Functions 
3
 3 Product Specifications 
6
 4 Dimensions 
12
 5 Refrigeration Cycle Diagram 
14
 6 Block Diagram 
15
 7 Wiring Diagram 
16
 8 Operation Details 
17
 9 Operating Instructions 
26
 10  Installation Instructions  
34
© 2003 Matsushita Industrial Corp. Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
CS-E719K CU-E719K
CS-E919K CU-E919K
CS-E1219K CU-E1219K
 11  2-way, 3-way Valve 44
 12  Servicing Information 
51
 13...

Page 2

 • High Efficiency
 • Compact Design
 • Comfort Environment
 − Air filter with function to reduce dust and smoke
 − W ider range of horizontal discharge air
 • Auto Restart
 − Random auto restart after power failure for safety restart
operation
 • Removable and Washa ble Front Panel
 • Remote Control Self-illuminating Button • Quality Improvement
 − Gas leakage protection
 − Prevent compressor reverse cycle
 − 2-stage OLP to protect compressor
 − Noise prevention during soft dry operation.
 • Operation...

Page 3

2 Functions
Remote Control
Operation OFF / ONOFF / ON IRoom Temperature SettingTEMP.
Operation Mode Selection
•AUTOAutomatic Operation Mode
•
COOLCooling Operation Mode
•
DRYSoft Dry Operation Mode
•
FANAir Circulation Mode
MODE
Indoor Fan Speed SelectionFAN SPEED
•Low Fan Speed
•
Medium Fan Speed
•
High Fan Speed
•
AUTOAutomatic Fan Speed
Vertical Airflow Direction ControlAIR SWING
•AUTOAutomatic Vertical Airflow
Direction Control
•
MANUALVertical Airflow Direction
Manual Control (5 stages of...

Page 4

Indoor Unit
Random Auto Restart Control
•Operation is restarted randomly after
power failure at previous setting mode.
Anti-Freezing Control
•Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Quiet Operation
•To provide extra quiet operation.
Indoor Fan Speed Control
•High, Medium and Low.
•Automatic Fan Speed Mode
–Cooling : Fan rotates at Hi, Me and
SLo speed. Deodorizing
control is available.
–Soft Dry: Fan rotates at Lo- speed.
Deodorizing control
is available.
•Automatic air...

Page 5

Outdoor Unit
•To protect compressor from reverse
rotation when there is a instantaneous
power failure.
60 Secs. Forced Operation Control
•Once the compressor is activated, it
does not stop within the first 60 secs.
However, it stops immediately with
remote control stop signal.
Overload Protector
•2-Stage OLP to protect the compressor.
Overload Protector will trip when
– Temperature of compressor increases
to 120°C.
– High temperature or high current flows
to compressor.
(Refer circuit diagram for OLP...

Page 6

3 Product Specifications
UnitCS-E719KCU-E719K
Power SourcePhase, Voltage, CycleSingle, 220 - 240, 50 Hz
Cooling CapacitykW (BTU/h)2.00 - 2.05 (6,820 - 6,990)
Moisture Removall/h (Pint/h)1.3 (2.7)
Airflow MethodOUTLET
INTAKE
SIDEVIEWTOP VIEW
Air VolumeIndoor Air (Lo)m3/min (cfm)6.0 (210) - 6.0 (210)—
Indoor Air (Me)m3/min (cfm)6.7 (240) - 6.7 (240)—
Indoor Air (Hi)m3/min (cfm)7.4 (260) - 7.4 (260)30.9 (1,090) - 32.3 (1,140)
Noise LeveldB (A)High 35 - 35, Low 26 - 26High 47 - 48
Power level dBHigh 45 -...

Page 7

UnitCS-E719KCU-E719K
ThermostatElectronic Control—
Protection Device—2 Stage Overload Protector
Capillary TubeLengthmm—845
Flow Ratel/min—9.9
Inner Diametermm—1.5
Air FilterMaterial
StyleP.P.
Honeycomb—
Capacity ControlCapillary Tube
Compressor CapacitorµF, VAC—20 µF, 400VAC
Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC
Note:
 • 
Specifica tions are subject to change without notice for further improvement.
7
CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K 

Page 8

UnitCS-E919KCU-E919K
Power SourcePhase, Voltage, CycleSingle, 220 - 240, 50 Hz
Cooling CapacitykW (BTU/h)2.65 - 2.70 (9,040 - 9,200)
Moisture Removall/h (Pint/h)1.6 (3.4)
Airflow MethodOUTLET
INTAKE
SIDEVIEWTOP VIEW
Air VolumeIndoor Air (Lo)m3/min (cfm)6.2 (220) - 6.2 (220)—
Indoor Air (Me)m3/min (cfm)7.2 (260) - 7.2 (260)—
Indoor Air (Hi)m3/min (cfm)8.4 (300) - 8.4 (300)30.9 (1,090) - 32.3 (1,140)
Noise LeveldB (A)High 37- 37, Low 26 - 26High 47 - 48
Power level dBHigh 50 - 50High 62 - 63
Electrical...

Page 9

UnitCS-E919KCU-E919K
Capillary TubeLengthmm—845
Flow Ratel/min—9.9
Inner Diametermm—1.5
Air FilterMaterial
StyleP.P.
Honeycomb—
Capacity ControlCapillary Tube
Compressor CapacitorµF, VAC—30 µF, 400VAC
Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC
Note:
 • 
Specifica tions are subject to change without notice for further improvement.
9
CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K 

Page 10

UnitCS-E1219KCU-E1219K
Power SourcePhase, Voltage, CycleSingle, 220 - 240, 50 Hz
Cooling CapacitykW (BTU/h)3.52 - 3.57 (12,000 - 12,200)
Moisture Removall/h (Pint/h)2.1 (4.4)
Airflow MethodOUTLET
INTAKE
SIDEVIEWTOP VIEW
Air VolumeIndoor Air (Lo)m3/min (cfm)7.6 (270) - 7.6 (270)—
Indoor Air (Me)m3/min (cfm)8.7 (310) - 8.7 (310)—
Indoor Air (Hi)m3/min (cfm)10.2 (360) - 10.2 (360)30.9 (1,090) - 32.3 (1,140)
Noise LeveldB (A)High 40 - 40, Low 29 - 29High 49 - 50
Power level dBHigh 53 - 53High 63 - 64...
Start reading Panasonic Cs E719k Cs E919 Kcs E1219k Repair Manual

Related Manuals for Panasonic Cs E719k Cs E919 Kcs E1219k Repair Manual

All Panasonic manuals