Home > Panasonic > Air Conditioner > Panasonic Cs W50bb4p Cu V50bbp8 Cu W50bbp8 Repair Manual

Panasonic Cs W50bb4p Cu V50bbp8 Cu W50bbp8 Repair Manual

Here you can view all the pages of manual Panasonic Cs W50bb4p Cu V50bbp8 Cu W50bbp8 Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.

Page 1

 1 SERVICE INFORMATION 3
 2 FEATURES 
4
 3 SPECIFICATION (HEAT PUMP TYPE ) 
10
 4 SPECIFICATION (COOLING ONLY TYPE ) 
11
 5 TECHNICAL DRAWING 
12
 6 CIRCUITDIAGRAM 
14
 7 OPERATING INSTRUCTION 
26
 8 REFRIGERATION CYCLE 
28
 9 OPERATIO N RANGE 
29
 10  PIPE LENGTH 
30
© 2002 Matsushita Industrial Corporation. Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
CS-W50BB4P CU-V50BBP8
CS-W50BB4P CU-W50BBP8
 11  OPERATING CHARACTERISTIC 32
 12  FAN...

Page 2

 20  TEST OPERATIO N AND SELF DIAGNOSIS 47
 21  SETTING OF SAVEENERGY AND THERMISTOR SWITCH 
51
 22  GROUP CONTROL 
52
 23  TROUBLESHOOTING  
53
 24  EMERGENCY OPERATIO N 
58
 25  CONTROL 
59 26  WIRED REMOTE CONTROLINSTALLA TION MANUAL 
70
 27  WIRELESS REMOTE CONTROLINSTALLA TION MANUAL 
75
 28  INSTALLA TION (INDOOR UNIT) 
82
 29  INSTALLA TION (OUTDOOR UNIT) 
91
 30  REPLACEMENT PARTS 
103
2 

Page 3

1 SERVICE INFORMATION
Caution:
OPb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use
a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
OPb free solder will tend to splash when heated too high (about 1100° F/600°C).
Notice of Address setting for NEW Cassette / NEW Outdoor Unit.
The new Casse tte / new Outdoor models are possible to have...

Page 4

2.1. Variety of excellent features
 
    • 
• •  • 
Compact design
Compact design 290 mm height, 840 mm width and 840
mm depth.
 
    • 
• •  • 
Automatic restart function
When theelectric power resumes after a power failure, the
unit will automatically restarts the operation in the pre-
failure mode.
 
    • 
• •  • 
Auto fan mode (indoor unit)
Auto fan mode is added beside s HI, ME and LO.
It automatically adjusts the fan speed according to the
indoor temperature.
 
    • 
• •  • 
Dry mode function
Dry...

Page 5

2.2.1. Product features
 
    • 
• •  • 
Low-noise design improves comfort in surrounding
areas
 1. The noise-suppressing winglet fan is a result of new
research into vane design theory. The unique curved
shape suppresses the generation of vortexes, thus
reducing air flow noise.
 2. The adoption of double -orifice rings reduces air
passage resistance.
 3. Strengthening of the noise insulation materials in the
compressor and the sealing-in of mechanical noise
allows vibration noise to be greatly enclosed...

Page 6

2.4. A brand-new control method
using the latest in technology
 
    • 
• •  • 
Easier power supply wiring connection
Power supply wiring and other wiring tasks can be carried
out more easily.
 
    − 
− −  − 
Twin non-polar wires used to connect indoor and
outdoor units.
 
    − 
− −  − 
Adoption of connection error prevention circuits for drive
wires and signal wires. If a connection error is made, the
relay does not operate and current does not flow to the
circuit boards.
 
    • 
• •  • 
Twin and...

Page 7

2.8. New refrigerant Series [R407C]
pipe installation
2.8.1. Procedure
 
    • 
• •  • 
The new refrigerant (R407C) has a different composition to
the previously-used refrigerant (R22), so some contents
and method of pipe installa tion and charging work are
different from before. Care should be taken whencarrying
out this work.
2.8.2. Installation and precautions
2.8.2.1. Before installation
 1. Determine the installa tion division.
 2. Check the refrigerant to be used.
 
    • 
• •  • 
Check that the...

Page 8

 
    • 
• •  • 
Do not work for refrigerant piping on outdoo r on rainy
days.
 
    • 
• •  • 
Seal by brazing.
 
    • 
• •  • 
Be sure to use only a non-oxidizing brazing material.
(Use nitrogen. Anti-oxidants cannot be used.)
 
    • 
• •  • 
W hen brazing pipes together, or when brazing copper
pipes and copper joints, use a brazing material (Bcup-3)
which does not require flux.
 
    • 
• •  • 
Flare processing and ester oil.
 
    • 
• •  • 
Sealing can be improved by applyin g ester oil or...

Page 9

9 

Page 10

3 SPECIFICATION (HEAT PUMP TYPE )
CS-W50B B4P / CU-W50B BP8
ITEM / MODELIndoor UnitOutdoor unit
Main BodyCS-W50BB4PCU-W50BBP8
PanelCZ-BT01P
RemoteCZ-RD51P (Wired)
ControlCZ-RL51P (Wireless)
Cooling CapacitykW14.0
BTU/h47,700
Heating CapacitykW16.0
BTU/h54,600
Refrigerant Charge-lessm30
Standard Air Volume for High Speedm3/min31
cfm1095
Outside Dimension (H x W x D)mm290 x 840 x 8401220 x 1100 x 320
inch11-7/16 x 33-1/24 x 33-1/2448-1/24 x 43-5/16 x 12-19/32
Net Weightkg33115
lbs73254
Piping...
Start reading Panasonic Cs W50bb4p Cu V50bbp8 Cu W50bbp8 Repair Manual

Related Manuals for Panasonic Cs W50bb4p Cu V50bbp8 Cu W50bbp8 Repair Manual

All Panasonic manuals