 1. Vertical Airflow Direction
 • The louver swings up and down as shown above.
 • The louver does not swing when the Indoor Fan stops
during operation at the upper limit.
Heating Mode
 • W hen the intake air temp. reaches 38°C, the louver is
changed from upper to lower limit.When theintake air
temp falls to 35°C, the louver is changed from lower to
upper limit.
 2. Horizontal Airflow Direction
 • The louver can be selected between 14°-36°(as
shown above) when pressing Manua l Airflow Direction
Selection...

Page 33

8.10. Powerful Mode Operation
Purpose of this operation is to be obtain the setting temperature quickly.
 1. Cooling and Soft Dry Mode
 • W hen the Powerful Mode is set, the set temperature will be automatically decreased 3°C against the present setting
temperature (Lower temperature: 16°C). This operation automatically will be running under SHi Fan speed (cooling), Lo-
Fan Speed (Soft Dry).
 • Vertical Airflow Direction:-
In“Manual”setting, the vane will automatically shift down 10°lower than previous...

Page 34

8.11. Ionizer Operation
Purpose
To provide fresh air effect to user by producing minus ion in discharge air.
Control Condition
a. Ionizer Only Operation.
 1. When air-conditioner unit is at“OFF”conditio n (standby) and ION operation button at remocon is pressed.
Fan & ionizer on, ION LED illuminates, but power LED maintain off. (1
→2)
However, fan speed can be adjusted later by customer during this operation.
Air flow direction (Horizontal Vane) control:
Follow vane direction control at cooling mode....

Page 35

Case 1a: Ionizer only operation (12h delaytimer ON)
Case 2a: Ionizer only operation (24h real time timer ON)
Case 1b: Ionizer only operation (12h delaytimer OFF)
Case 2b: Ionizer only operation (24h real time timer OFF)
 3. Ionizer operation status is not memorised after off. After OFF,when operation is“ON”again, air-conditio ner operates without
ionizer operation.
However, during Cool mode etc. + ionizer operation, if there is a power failure & then power resume, A/con shall on at that
mode + ionizer...

Page 36

Case 3a: Operation Mode + Ionizer (12h delaytimer ON)
Case 4a: Operation Mode + Ionizer (24h real time timer ON)
Case 5a: Ionizer only operation (24h real time timer ON)
Case 6a: Ionizer only operation (12 delaytimer ON)
Case 7a: Operation Mode + Ionizer (12 delaytimer ON)
Case 3b: Operation Mode + Ionizer (12h delaytimer OFF)
Case 4b: Operation Mode + Ionizer (24h real time timer OFF)
Case 5b: Ionizer only operation (24h real time timer OFF)
Case 6b: Ionizer only operation (24h real time timer ON)
Case...

Page 37

Note:
 1. 24 times checking: Actual Ion ON for 10s & OFF for 1s 30 min continuously for 24 times.
 2. 24 times count will be cleared when followin g conditio ns happen .
a) 24 times count over, b) Ionizer cancel if press Ion button or power reset, c) Ion f/b sgnl OK.
 3. Error protection will be cleared when followin g conditio ns happen .
a) Power reset, b) Remocon operation ON/OFF button press, c) Forcible operation press, d) Opt OFF due to Timer OFF
 4. Ion auto restart: Ion will auto restart if...

Page 38

38
CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 

Page 39

9 Operating Instructions
SAFETY PRECAUTIONS
Before operating, please read the following
“Safety Precautions” carefully.
To prevent personal injury, injury to others and
property damage, the following instructions must be
followed.
Incorrect operation due to failure to follow instructions
will cause harm or damage, the seriousness of which
is classified as follow:
! WarningThis sign warns of death or serious injury.
! CautionThis sign warns of damage to property.
The instructions to be followed are...

Page 40

NAME OF EACH PART
Remote Control
Remote Control Signal.
Make sure it is not obstructed.
Maximum distance : 10 m.
Signal received sound.
One short beep or one long beep.
Notes for Remote Control.
Do not throw or drop.
Do not get it wet.
Certain type of fluorescent lamps may affect
signal reception. Consult your dealer.
CHECK
TEMPAUTOONOFF
AUT
AUTODR
DRYFAN
ANCOOL
COOL
FAN AUTO
RESETCLOCK
MODEPOWERFULQUIET
FAN SPEEDAIR SWING
OFFCANCELONSET12
3
TIMER
OFF/ON
AUTOMANUAL
# !
$
%^
$
* &
3
5
87
9
0
6 4...
Start reading Panasonic Cs W7ckp Cs W9ckp Cs W7ckp Series Repair Manual

Related Manuals for Panasonic Cs W7ckp Cs W9ckp Cs W7ckp Series Repair Manual

All Panasonic manuals