    Setting the beep volume
    Set the beep volume with the volume switch.
    Low volume
    (Approx. 70 dB)
    OFFHigh volume
    (Approx. 85 dB)
    NOTE
    The  beep  mode  setting  is  configured  while  the  assembly  qualifier  is  connected  to  a 
    computer. See page 7.
    Using the software
    1. Turn on the assembly qualifier’s power switch.  
    All indicators will turn on and off, leaving only the power 
    indicator on.
    2. Use the registered tool to perform fastening work. 
    Status of tool’s fastening 
    confirmation indicator
    Assembly qualifier 
    indicators
    GreenFastening PASS 
    indicator
    RedFastening FAIL 
    indicator
    Finishing work
    Turn off the assembly qualifier’s power switch.
    I/O connector
    Pin no.Description
    1Reset input pin (input)
    Reset input pin (common)
    3Relay output pin (common)
    4Relay output pin (fastening PASS)
    5Relay output pin (fastening FAIL) 
    						
    							
    - 1 - 
    
    5-pin connector schematic and pin out
    To connect to the 5-pin connector, you will need:
    A commercially available round connector  
    (manufacturer: Amphenol ; model no.: T3360 001)
    System wiring
    1. Unplug the assembly qualifier and turn off the power switch.
    2. Connect the assembly qualifier to an external device (sequencer, etc.).
    Example connection
    Assembly qualifier External device
    Input Rated: 4V/60mA
    Rated input: 4V/60mA
    Input Rated: AC50V/5ARated output: DC30V/5A
    Input Rated: AC50V/5ARated output: DC30V/5A
    PLC, etc.
    Input signal for analyzing output
    Relay
    Relay
    PLC, etc.
    CAUTION
    Exercise caution not to exceed the rated load as doing so may damage internal circuitry. 
    						
    							
    - 13 -  
    
    IV.	SPECIFICATIONS
    ModelEYFR0
    Rated supply voltage100/40, 50/60 Hz
    Rated supply current 0.1 A
    Frequency.410 GHz to .465 GHz
    Recommended communications range10 m*
    No. of connected devices1
    External connection output5A at AC50V or 5A at DC30V
    Operating temperature range–10ºC (14ºF) to 60ºC (140ºF)
    Compatible toolsEYFLA4AR, EYFLA5AR, EYFLA5QR, EYFLA6JR,  EYFLA6PR, EYFMA1JR, EYFMA1PR
    Dimensions 10 mm × 60 mm × 70 mm
    Weight1.1 kg
    * Communications  range  varies  with  operating  environment. The  presence  of  metal  walls,  people,  or other objects may result in decreased range.
    Radio Information:
    Indoor/Urban Range  100 ft./30 m
    Transmit Power  1 mW (0 dBm)
    Receiver Sensitivity   -9 dBm (1% B0 packet error)
    FCC Part 15.47  OUR-XBEE
    Industry Canada  414A XBEE
    FCC Statement: 
    Contains FCC ID: OUR-XBEEThe enclosed device complies with Part 15 of the FCC Rules. Operation is\
     subject to the following two conditions: (i.) this device may not cause harmfu\
    l interference and (ii.) this device must accept any interference received, including\
     interference that may cause undesired operation.
    Channel Frequencies:
     Channel 1 .410 GHz
      Channel  .415 GHz
      Channel 3 .40 GHz
      Channel 4 .45 GHz
      Channel 5 .430 GHz
      Channel 6 .435 GHz
      Channel 7 .440 GHz
      Channel 8 .445 GHz
      Channel 9 .450 GHz
      Channel 10 .455 GHz
      Channel 11 .460 GHz
      Channel 1 .465 GHz 
    						
    							
    - 15 -  
    
    -MEMO-  
    						
    							
    PANASONIC CONSUMER ELECTRONICS COMPANYOne Panasonic Way, Secaucus, New Jersey 07094
    EN
    EY9811FRZ01 H110  Printed in Japan 
    						