Panasonic Live Switcher Aw Sw350 Operating Instructions
Have a look at the manual Panasonic Live Switcher Aw Sw350 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

21 20 The AW-SW350 Live Switcher comes with a function for transferring images from the host computer using the USB (Universal Serial Bus). The image data transferred from the host computer can be used as the key input signals or main input signals of the AW-SW350. When the image transfer function is to be used for the first time, the dedicated device driver and application program must be installed in the host computer. They can be installed from the CD-ROM that is supplied with the AW-SW350. For details on how to install them, refer to “Installing the Device Driver” and “Installing the Application Program”.FUNCTIONSThe USB image transfer program used with the AW-SW350 contains the following functions. • Frame memory image transfer function (RAM) • Flash memory image transfer function (ROM) • Image cutout position designation function • Image start position designation function For more details on how to use these functions, refer to “Operation Method”. SPECIFICATIONSIn order for the host computer to run the USB image transfer program used with the AW-SW350, it must satisfy the following system requirements. Image files in two formats, the bitmap format (bmp) and JPEG format (jpg, jpeg), can be used with the USB image transfer program for the AW-SW350. Also required separately when using the image transfer function is the A-B type USB cable for connecting the host computer with the AW-SW350. IMAGE TRANSFER FUNCTION Processor Pentium III, 1 GHz or up recommendedRAM 128 MB or moreFree hard drive memory 50 MB or more Operating system Windows 98 Second Edition (SE), Windows Me, Windows 2000, Windows XP USB port USB Version 1.1 or up CD-ROM drive EssentialMore time is required to transfer the images if the performance of the personal computer is low-level. The function will not work with versions of Windows that are not recommended (Windows 3.1, Windows 95, Windows 98, Windows NT4.0 ). Pentium is a registered trademark of Intel Corporation. Windows, Windows 98, Windows Me, Windows 2000 and Windows XP are registered trademarks of Microsoft Corporation. Caution

23 22 INSTALLING THE DEVICE DRIVERThis section describes how to install the device driver used with the USB image transfer program for the AW-SW350. In the example of the procedure given below, Windows XP is used as the operating system. Insert the CD-ROM supplied with the AW-SW350 in the CD-ROM drive of the host computer. (In this example, E: is the drive used.) Set the AW-SW350s Power Switch to ON, check that the Power Indicator has lighted, and connect one end of the A-B type USB cable to the USB port on the rear panel of the AW-SW350 and the other end to the USB port on the host computer. (Fig.1) When the host computer recognizes the AW-SW350, as shown in Fig.2, the Found New Hardware Wizard automatically starts up.3 2 1 When the screen for specifying the driver loading directory appears as shown in Fig.3, specify the \DRIVER folder of the drive where the CD-ROM supplied with the AW-SW350 was inserted, and load the driver. (In this example, E: is the drive used.) When the device driver has been loaded, a screen similar to the one shown in Fig.4 appears. This completes the installation of the device driver. 5 4 Fig.1 Connections BBOUT GLIN /BBOUTPVW OUTTALLY & INCOM PGM OUT 2 54 DC 12V IN SET UPUSBEXT TAKE PGMY / COUT 1342 GND 32111 75Ω AUTO 2 3 4 5 1 2 3 4 5 VIDEO IN OUT Y / C IN AW-SW350 Windows PC USB cable Rear Fig.2 Found New Hardware Wizard start screen Fig.3 Driver specification screen Fig.4 Driver loading completion screen

25 24 INSTALLING THE APPLICATION PROGRAMThis section describes how to install the application program used with the USB image transfer program for the AW-SW350. In the example of the procedure given below, Windows XP is used as the operating system. Insert the CD-ROM supplied with the AW-SW350 in the CD-ROM drive of the host computer. (In this example, E: is the drive used.) Run the “Microsoft .Net Framework” setup file (E:\JPN\DOTNETFX.EXE). The installer program shown in Fig.6 now starts. Proceed with the installation by following the installer instructions. Run the setup program (E:\JPN\SETUP.EXE).4 3 2 1 In order to confirm that the device driver has been installed successfully, it is recommended that you open the Device manager as shown in Fig.5, and check that “AW-SW USB Device:AW-SW350” is displayed. 6 Fig.5 Device manager screen Fig.6 Microsoft .Net Framework installer start screen

27 26 OPERATION METHODThis section describes how to operate the application program used with the USB image transfer program for the AW-SW350. Connect the host computer to the AW-SW350. (Check that the AW-SW350s power is on.) The main screen shown in Fig.9 appears when the application program used with the USB image transfer program for the AW-SW350 is started up. When the “Open File” button is clicked, the file selection dialog box shown in Fig.10 appears. Select the image file (BMP, JPG or JPEG) to be transferred, and click “OK”.3 2 1 The installer program shown in Fig.7 now starts. Proceed with the installation by following the installer instructions. This completes the installation of the application program. 6 5 Fig.7 Application program installer start screen Fig.8 Application program installation completion screen Fig.9 Application program main screen Fig.10 File selection dialog box

29 28 When the target image appears in the image display area, specify the start or cutout position of the image. Which position is to be specified is determined by the number of pixels in the image file. • No. of pixels that can be displayed: 720 (H) x 487 (V) • When the file is smaller than the number of pixels that can be displayed: The spaces around the image are displayed in black. Move the image to the position where it is to be displayed. • When the file is larger than the number of pixels that can be displayed: The frame outlining what can be displayed appears. Move the frame to the position where the image to be displayed is framed. Drag the image displayed in the screen display area and drop it to change its position. (Fig.11) 4 Drag the frame displayed in the screen display area and drop it to change the cutout position. (Fig.12) specify the start position of the image AW-SW350 program output Fig.11 Specifying the image start position specify the cutout position of the image AW-SW350 program output Fig.12 Specifying the image cutout position

31 30 Click the “RAM” radio button or “RAM+ROM” radio button to select the type of memory in which the data will be saved. (Fig.13) If “RAM” is selected, the image data is saved only in the frame memory and so it cannot be used after the AW-SW350 power has been turned off and back on again. If “RAM+ROM” is selected, the image data is saved in the flash memory and so it can be used after the AW-SW350 power has been turned off and back on again. However, the actual transfer takes longer than when “RAM” is selected. Click the “Write USB” button to start transferring the image data. After the completion of the transfer, monitor the AW-SW350s PGM output and check that the image data has been transferred. (Fig.14) 6 5 — When images could not be transferred — If an error resulted or images could not be transferred because a cable was connected or disconnected, turn off the switchers power and exit the application program. Then turn the switchers power back on again and start up the application again. Status after power has been turned off and back on again Transfer time RAM Transferred image data cannot be used Approx. 10 sec. RAM+ROM Transferred image data can be used Approx. 60 sec.✽The transfer times given in the above table are approximations only. The actual time taken will depend on the performance of the host computer. Fig.13 Memory selection Click the buttonAW-SW350 program output Fig.14 PGM check

33 32 CONNECTION FOR EXTERNAL SYNCHRONIZATION (Frame Synchronizer OFF)Adjust the horizontal and color phases of the cameras. (Read the manual for the camera.) CONNECTION WITHOUT EXTERNAL SYNCHRONIZATION (Frame Synchronizer ON)CONNECTIONSFor installation and connection, be sure to ask the store where you purchased the product. Before making any connection, switch off all the components of the system. Carefully read the manuals for the individual devices connected to the Live Switcher. Use coaxial cable to connect video and genlock signals. BBOUT GLIN /BBOUTPVW OUTTALLY & INCOM PGM OUT 2 54 DC 12V IN SET UPUSBEXT TAKE PGMY / COUT 1342 GND 32111 75Ω AUTO 2 3 4 5 1 2 3 4 5 VIDEO IN OUT Y / C IN PVW OUT AW-SW350 Convertible Camera AW — E600 Convertible Camera AW — E600 Convertible Camera AW — E600 PGM OUT VIDEO OUTVIDEO OUT Convertible Camera AW — E600 VIDEO OUT Camera Color monitors Camera or character generator for key synthesis Signal generator ✽ When a signal generator is used to generate the reference signals for the system AC adaptor AW-PS505 QFS switch [ON] WGLIN/BBOUT switch [GLIN] VCR, etc. BBOUT GLIN /BBOUTPVW OUTTALLY & INCOM PGM OUT 2 54 DC 12V IN SET UPUSBEXT TA K E PGMY / COUT 1342 GND 32111 75Ω AUTO 2 3 4 5 1 2 3 4 5 VIDEO IN OUT Y / C IN AW-SW350 Convertible Camera AW — E600 Convertible Camera AW — E600 Convertible Camera AW — E600 1 2 3 1 2 3OUTPUT B OUTPUT A INPUT THR SEP 75ΩHI-Z BA PVW OUT PGM OUT VIDEO OUT G/L INVIDEO OUT OUTPUT INPUTG/L IN G/L IN Convertible Camera AW — E600 VIDEO OUT Camera Color monitors Camera or character generator for key synthesis Video distributor WJ-300CAC adaptor AW-PS505 QFS switch [OFF] WGLIN/BBOUT switch [BBOUT] VCR, etc. When unstable video signals, such as those from a VCR, are being used for the input signals, the internal frame synchronizer may not operate correctly. Caution

35 34 CONNECTION TO PERSONAL COMPUTER E600 E600 E600 E600 Windows PC BBOUT GLIN /BBOUTPVW OUTTALLY & INCOM PGM OUT 2 54 DC 12V IN SET UPUSBEXT TAKE PGMY / COUT 1342 GND 32111 75Ω AUTO 2 3 4 5 1 2 3 4 5 VIDEO IN OUT Y / C IN AW-SW350 Convertible Camera AW — E600 Convertible Camera AW — E600 Convertible Camera AW — E600 OUT VIDEO OUTVIDEO OUT Convertible Camera AW — E600 VIDEO OUT These switches operate whether the FS switch is in the ON or OFF position. Color monitors Connected with USB cable AC adaptor AW-PS505 VCR, etc. Camera or character generator for key synthesisCamera

37 36 EXAMPLE FOR THE CONNECTION WITH PAN/TILT HEADS AND CONTROL PANELThe cameras can be locally controlled by using the pan/tilt head AW-PH300A, multi-hybrid control panel AW-RP505, and multi-port hub AW-HB505. TALLYDC12V IN AUX CONTROL IN 1 2 3 4 5 PREVIEW IN OUT G/L OUTPREVIEW MONITOR OUT CONTROL CONTROL OUTPAN/TILT CAMERA TD MULTI PORT HUBG / L IN E600 E600 E600 VIDEO OUT 1-4 E600 G/L IN G/L OUT CAMERA CONTROL OUTCAMERA CONTROL IN VIDEO OUTPAM/TILT CONTROL OUTPAM/TILT CONTROL IN S-VIDEO OUT VIDEO IN G/L OUTG/L IN CAMERA CONTROL OUTVIDEO OUTPAM/TILT CONTROL OUT S-VIDEO OUT VIDEO IN G/L OUT CAMERA CONTROL OUTVIDEO OUTPAM/TILT CONTROL OUT S-VIDEO OUT VIDEO IN G/L OUT CAMERA CONTROL OUTVIDEO OUTPA M / T I LT CONTROL OUT S-VIDEO OUT VIDEO IN G/L OUT CAMERA CONTROL OUTVIDEO OUTPA M / T I LT CONTROL OUT S-VIDEO OUT VIDEO IN G/L OUT 4 3 2 1 5 DC12V IN TO CAMERA PAM/TILT HEAD TO CONTROL PANELPREVIEW OUT SEE MANUAL Pan/tilt head cameras 1 to 4To pan/tilt head AW-PH300A, Camera AW-E300/E600/E800A Multi-port hub AW-HB505 Multi-hybrid control panel AW-RP505 AC adaptor AW-PS301 AC adaptor AW-PS505 Preview monitor The FS switch may be in either the ON or OFF position. If high picture quality is desired, set the FS switch to OFF and adjust each camera for horizontal and color phases. (Refer to the instruction manual for the camera.) BBOUT GLIN /BBOUTPVW OUTTALLY & INCOM PGM OUT 2 54 DC 12V IN SET UPUSBEXT TAKE PGMY / COUT 1342 GND 32111 75Ω AUTO 2 3 4 5 1 2 3 4 5 VIDEO IN OUT Y / C IN AW-SW350 Convertible Camera AW — E600 Convertible Camera AW — E600 Convertible Camera AW — E600 VIDEO IN 1-4 PVW OUT PGM OUT Convertible Camera AW — E600 VIDEO OUT G/L INVCR, etc. AC adaptor AW-PS505 Camera or character generator for key synthesisColor monitors

39 38 RACK MOUNTINGRACK MOUNTINGDo not mount the Live Switcher on a closed rack or bookshelf. (Otherwise, heat will build up inside and may cause a fire.) Keep the ventilation port open to secure good flow of air. POW ERIN C O M L E V E L G E N -L O C K P H A S E WIPE PATTERN T R A N S I T IO N T I M EKEY SETTINGCOLORW H 1 S F 0WH2 SF1WH3 AUTO TAKEKEY AUTO A G A I NSOURCEI N 5FMEM KEY AUTOCLIP SF2 Y L W M W RCYN INTGRN FRZ M G TREDBLEN N / R RINV HS CSC FINE ONOFF A 1234 5 F M E MB L A C K W I P EA U T O T A K EB A R C O L O R B BM IX F R Z Rack mounting parts Mounting screw Mounting screw Holes for connecting plate (Bottom)Connecting plate INFORMATION RELATED TO SYSTEM UPGRADES(1) Switcher phases1) Video signal output phase (frame synchronizer is OFF) 2) Video signal input phase (frame synchronizer is ON) 3) Genlock adjustment range(2) TALLY & INCOM connectorsUse a Mini DIN type 6-pin connector for tally and intercom connections. (e.g.) TCP8060-01-520 manufactured by Hosiden Corporation BB phase Video signal input phase Video signal output phase Approx. 50nSInput phase range max. of 1 frame BB phase Approx. 3µSApprox. 1µS BB phase