Home > Panasonic > Projector > Panasonic Projector PT-DZ21KU User Manual

Panasonic Projector PT-DZ21KU User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Projector PT-DZ21KU User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Technical information
    ENGLISH - 161
    Appendix
    Technical information
    PJLink protocol
    The network function of this projector supports the PJLink class 1, and the PJLink protocol can be used to 
    perform projector setting and projector status query operations from a computer.
    ▶■Control commands
    The following table lists the PJLink protocol commands that can be used to control the projector
    .
    CommandControl detailsRemark
    POWR Power supply control Parameters
    0 = Standby
    1 = Power on
    POWR? Power supply status query Parameters
    0 = Standby
    2 = Preparing to switch off 
    the projector
    1 = Power on
    3 = Warm-up in progress
    INPT Input selection Parameters
    11=RGB1
    31=DVI-D
    12=RGB2
    32=HDMI21=VIDEO
    33=SDI 1 (only for PT-DZ21KU, PT-DS20KU)
    34=SDI 2 (only for PT-DZ21KU, PT-DS20KU)
    INPT? Input selection query
    AVMT Shutter control
    Parameters
    30 = shutter function off (picture mute canceled)
    31 = shutter function on (picture mute)
    AVMT? Shutter status query
    ERST? Error status query Parameters
    1st byte: Indicates fan errors, range 0 - 2
    2nd byte: Indicates lamp errors, range 0 - 2
    3rd byte: Indicates temperature errors, range 0 - 2
    4th byte: Fixed to 0
    5th byte: Indicates filter errors, range 0 - 2
    6th byte: Indicates other errors, range 0 - 2
    Definitions for each value from 0 to 2 are as follows
    0 = No error is detected 1 = Warning  2 = Error
    LAMP? Lamp status query Parameters
    1st digits (1 - 5 digits): Lamp 1 cumulative operating time
    2nd digit: 0 = Lamp 1 off, 1 = Lamp 1 on
    3rd digits (1 - 5 digits): Lamp 2 cumulative operating time
    4th digit: 0 = Lamp 2 off, 1 = Lamp 2 on
    5th digits (1 - 5 digits): Lamp 3 cumulative operating time
    6th digit: 0 = Lamp 3 off, 1 = Lamp 3 on
    7th digits (1 - 5 digits): Lamp 4 cumulative operating time
    8th digit: 0 = Lamp 4 off, 1 = Lamp 4 on
    INST? Input selection list query Parameters are returned with the following values.
    “11 12 21 31 32” (only for PT-DW17KU)
    “11 12 21 31 32 33 34” (only for PT-DZ21KU, PT-DS20KU)
    NAME? Projector name query Returns the name set in [PROJECTOR NAME] of [NETWORK 
    SETUP].
    INF1? Manufacturer name query Returns “Panasonic”.
    INF2? Model name query Returns “DZ21KU”, “DS20KU”, “DW17KU”.
    INF0? Other information queries Returns information such as version number.
    CLSS? Class information query Returns “1”. 
    						
    							Technical information
    162 - ENGLISH
    Appendix
    ▶■PJLink security authentication
    The password used for PJLink is the same as that of the password set for W
    eb control.
    When using the projector without security authentication, do not set a password for W eb control.
    ▶zFor specifications regarding PJLink, refer to the Japan Business Machine and Information System 
    Industries 
    
    Association website.
    URL http://pjlink.jbmia.or.jp/english/
    Using Art-Net function
    The network function of the projector supports the Art-Net function. Using the Art-Net protocol, you can control the 
    projector settings with the DMX controller and application software.
    ▶■ Channel definition
    The following table lists the channel definitions used for controlling the projector with the 
    Art-Net function.
    Channel Control detailsPerformance Parameter Remark
    1 Shutter control SHUTTER:OPEN 0-63
    No operation
    64-191
    SHUTTER:CLOSE 192-255
    2 Input selection No operation
    0-7
    RGB1 8-15
    RGB2 16-23
    VIDEO 24-31
    DVI
    - D32-39
    HDMI 40-47
    SDI 1 48-55
    (Only for 
    PT-DZ21KU/PT-DS20KU)
    SDI 2 56-63
    No operation 64-127
    Execute P IN P, USER1 128-135
    Execute P IN P, USER2 136-143
    Execute P IN P, USER3 144-151
    No operation 152-255
    3 Lens function select No operation
    0-15
    Lens H shift 16-31
    Operate together with “Lens 
    adjustment” of the channel 4.
    Lens V shift
    32-47
    Lens focus 48-63
    Lens zoom 64-79
    Move to the home position 80-95 Operate together with 
    “Command performance 
    execute” of the channel 4.
    No operation 96-255 
    						
    							Technical information
    ENGLISH - 163
    Appendix
    Channel Control detailsPerformance Parameter Remark
    4 Lens control Lens 
    adjustment
    (
    -) High 
    speed 0-31
    (
    -) Low 
    speed 32-63
    (
    -) Fine 
    adjustment 64-95
    Adjustment stop 96-127
    Lens 
    adjustment (+) Fine 
    adjustment
    128-159
    (+) Low 
    speed 160-191
    (+) High 
    speed 192-223
    Command performance 
    execute 224-255
    5 Power supply control Standby
    0-63
    No operation 64-191
    Power on 192-255
    6 Light volume adjustment 100
     
    % 0
    Can be set in 256 steps 
    between 100 % and 0 %.
    …
    …
    0
     
    % 255
    7 Lock Operation not available 0-127 When “Operation not 
    available” is set, operations 
    of all channels become 
    unacceptable.
    Operation available 128-255
    8 Fade-in time setting 0.0s
    0-15
    Operate together with channel 
    1.
    0.5s
    16-31
    1.0s 32-47
    1.5s 48-63
    2.0s 64-79
    2.5s 80-95
    3.0s 96-111
    3.5s 112-127
    4.0s 128-143
    5.0s 144-159
    7.0s 160-175
    10.0s 176-191
    No operation 192-255 
    						
    							Technical information
    164 - ENGLISH
    Appendix
    Channel Control detailsPerformance Parameter Remark
    9 Fade-out time setting 0.0s
    0-15
    Operate together with channel 
    1.
    0.5s
    16-31
    1.0s 32-47
    1.5s 48-63
    2.0s 64-79
    2.5s 80-95
    3.0s 96-111
    3.5s 112-127
    4.0s 128-143
    5.0s 144-159
    7.0s 160-175
    10.0s 176-191
    No operation 192-255
    10 Custom masking OFF
    0-31
    To use this function, the 
    optional upgrade kit (Model 
    No.: ET-UK20) is required.
    PC-1
    32-63
    PC-2 64-95
    PC-3 96-127
    No operation 128-255
    11 GEOMETRY OFF
    0-15
    To use PC-1, PC-2, or PC-
    3, the optional upgrade kit 
    (Model No.: ET-UK20) is 
    required.
    KEYSTONE
    16-31
    CURVED 32-47
    PC-1 48-63
    PC-2 64-79
    PC-3 80-95
    CORNER CORRECTION 96-111
    No operation 112-255
    Note
     z If the projector is operated with the remote control or on the control panel, or by the control command while 
    controlling the projector by using the 
    
    Art-Net function, the setting of the DMX controller and the computer 
    application may be different from the projector status. In that case, set the “Lock” setting of the channel 7 to 
    “Operation not available” and then reset to “Operation available”.  The controls of all channels become reflected 
    to the projector. 
    						
    							Technical information
    ENGLISH - 165
    Appendix
    Control commands via LAN
    ▶■When W eb control administrator rights password is set (Protect mode)
    ▶z
    Connecting
    1)  
    Obtain the IP
      address and port number (Initial setting value = 1024) of the projector 
    and request for a connection to the projector.
    You can obtain both the IP address and the port number from the menu screen of the projector.
    IP address Obtain from the main menu → [NETWORK] → [NETWORK STATUS]
    Port number Obtain from the main menu → [NETWORK] → [NETWORK CONTROL] → [COMMAND 
    PORT]
    2) Check the response from the projector
    Response data
    Data section Blank Mode Blank Random number section Termination 
    symbol
    “NTCONTROL” (ASCII string) ‘ ’
    0x20 ‘1’
    0x31 ‘ ’
    0x20 “zzzzzzzz”
    (ASCII code hexadecimal  number) (CR)
    0x0d
    9 bytes 1 byte 1 byte 1 byte 8 bytes1 byte
    Mode: 1 = Protect mode
    3) Generate a 32-byte hash value from the following data using MD5 algorithm.
    “xxxxxx:yyyyy:zzzzzzzz”
    xxxxxx Administrator rights user name for Web control (default user name is “admin1”)
    yyyyy Password of above administrator rights user (default password is “panasonic”)
    zzzzzzzz 8-byte random number obtained in Step  2)
    ▶zCommand transmission method
    Transmit using the following command formats.
    Transmitted data
    Header
    Data sectionTermination 
    symbol
    Hash value
    (“Connecting” (
     page 165)) ‘0’
    0x30 ‘0’
    0x30 Control command
    (ASCII string) (CR)
    0x0d
    32 bytes 1 byte 1 byte Undefined length1 byte
    Received data
    Header Data sectionTermination 
    symbol
    ‘0’
    0x30 ‘0’
    0x30 Control command
    (ASCII string) (CR)
    0x0d
    1 byte 1 byteUndefined length 1 byte
    Error response
    Error message Termination symbol
    “ERR1”
     
    Undefined control command
    “ERR2”
    
     
    Out of parameter range
    “ERR3”
    
     
    Busy state or no-acceptable period
    “ERR4”
    
     
    T
    
    imeout or no-acceptable period
    “ERR5”
     
    W
    
    rong data length
    “ERRA”
     
    Password mismatch (CR)
    0x0d
    4 bytes 1 byte 
    						
    							Technical information
    166 - ENGLISH
    Appendix
    ▶■When W eb control administrator rights password is not set (Non-protect 
    mode)
    ▶z Connecting
    1)  
    Obtain the IP
      address and port number (Initial set value = 1024) of the projector and 
    request for a connection to the projector.
    You can obtain both the IP address and the port number from the menu screen of the projector.
    IP address Obtain from the main menu → [NETWORK] → [NETWORK STATUS]
    Port number Obtain from the main menu → [NETWORK] → [NETWORK CONTROL] → [COMMAND 
    PORT]
    2) Check the response from the projector
    Response data
    Data section
    BlankModeTermination 
    symbol
    “NTCONTROL” (ASCII string) ‘ ’
    0x20 ‘0’
    0x30 (CR)
    0x0d
    9 bytes 1 byte1 byte1 byte
    Mode: 0 = Non-protect mode
    ▶z Command transmission method
    Transmit using the following command formats.
    Transmitted data
    Header
    Data sectionTermination 
    symbol
    ‘0’
    0x30 ‘0’
    0x30 Control command
    (ASCII string) (CR)
    0x0d
    1 byte 1 byteUndefined length 1 byte
    Received data
    Header Data sectionTermination 
    symbol
    ‘0’
    0x30 ‘0’
    0x30 Control command
    (ASCII string) (CR)
    0x0d
    1 byte 1 byteUndefined length 1 byte
    Error response
    Error message Termination symbol
    “ERR1”
     
    Undefined control command
    “ERR2”
    
     
    Out of parameter range
    “ERR3”
    
     
    Busy state or no-acceptable period
    “ERR4”
    
     
    T
    
    imeout or no-acceptable period
    “ERR5”
     
    W
    
    rong data length
    “ERRA”
     
    Password mismatch (CR)
    0x0d
    4 bytes 1 byte 
    						
    							Technical information
    ENGLISH - 167
    Appendix
    / terminal
    The / terminal of the projector conforms with RS-232C so that the projector can be 
    connected to and controlled from a computer.
    ▶■Connection
    When using 1 unit
    When using multipl\
    e units
    Connecting termina\Dls on projector 1Connecting termina\Dls on projector 2
     D\fSub \b\fpin 
    (female)  D\fSub \b\fpin 
    (male)  D\fSub \b\fpin 
    (female)  D\fSub \b\fpin 
    (male)Connecting termina\Dls on this device
    Computer Computer D\fSub \b\fpin (female)
     D\fSub \b\fpin (male)  D\fSub \b\fpin 
    (female)  D\fSub \b\fpin 
    (male)
     D\fSub \b\fpin (male)
    Communication cable\D
    Communication cable\D Communication cable\D
    ▶■Pin assignments and signal names
    D-Sub 9-pin (female)
    Outside view Pin No. Signal name
    Details
    (9) (6)
    (5) (1)
    (1)
    — NC
    (2) TXD Transmitted data
    (3) RXD Received data
    (4) — Connected internally
    (5) GND Earth
    (6) — NC
    (7) CTS
    Connected internally
    (8) RTS
    (9) — NC
    D-Sub 9-pin (male)
    Outside view Pin No. Signal name
    Details
    (6) (9)
    (1) (5)
    (1)
    — NC
    (2) RXD Received data
    (3) TXD Transmitted data
    (4) — NC
    (5) GND Earth
    (6) — NC
    (7) RTS
    Connected internally
    (8) CTS
    (9) — NC
    ▶■Communication conditions
    Signal level
    RS-232C-compliant Character length8 bits
    Sync. method Asynchronous Stop bit1 bit
    Baud rate 9
      600 bps X parameterNone
    Parity None S parameterNone         
    						
    							Technical information
    168 - ENGLISH
    Appendix
    ▶■Basic format
    Transmission from the computer starts with STX, then the ID, command, parameter, and ETX are sent in this 
    order. Add parameters according to the details of control.
    (2 bytes)
    2 ID characters (2\o bytes)
    Semico\fon (1 byte)
    Co\fon\b1 
    9Ô1 byte
    9Õ3 command 
    characters (3 byte\os)Parameter 
    (undefined \fength)End
    (1 byte)
    Start
    (1 byte)ID designate
    ZZ, 01 to 64 and 0A t\oo 0Z
    *1: When transmitting a command which does not need a parameter , a colon (:) is not necessary.
    ▶■Basic format (with subcommands)
    Parameter (6 bytes\“)*1
    Symbol “\f” or “-” (1\“ byte) an\b setting 
    or a\bjustment value\“ (5 bytes)
    Operation (1 byte)
    *1
    “=” (Set the value \“specifie\b using param\“eter)
    Sub comman\b 
    (5 bytes)
    Same as the basic \“format
    *1: When transmitting a command which does not need a parameter , the operation (E ) and parameter are not necessary.
    Attention
     zIf a command is transmitted after the lamp starts illuminating, there may be a delay in response or the 
    command may not be executed. 
    
    Try sending or receiving any command after 60 seconds.
     zWhen transmitting multiple commands, be sure to wait until 0.5 seconds has elapsed after receiving the 
    response from the projector before sending the next command.
    Note
     z If a command cannot be executed, a “ER401” response is sent from the projector to the computer
    .
     zIf an invalid parameter is sent, a “ER402” response is sent from the projector to the computer
    .
     zID transmission in RS-232C supports ZZ (ALL) and 01 to 64, as well as 0A
     to 0Z groups.
     zIf a command is sent with a specified ID, a response will be sent to the computer only in the following cases.
    –
    
    ▶
    It matches the projector ID
    –
    
    ▶
    ID setting is set to 
     ALL and [RESPONSE(ID ALL)] is [ON]
    –
    ▶
    ID setting is set to GROUP
      and [RESPONSE(ID GROUP)] is [ON]
     zSTX and ETX are character codes. STX shown in hexadecimal is 02, and ETX shown in hexadecimal is 03. 
    						
    							Technical information
    ENGLISH - 169
    Appendix
    ▶■When multiple projectors are controlled
    ▶z
    When multiple projectors are all controlled
    When controlling multiple projectors together via RS-232C, perform the following settings.
    1) Set a different ID for each projector
    2)  
    Set [RESPONSE(ID 
     ALL)] to [ON] in only one projector
    3)
     
    Set [RESPONSE(ID 
     ALL)] to [OFF] for all other projectors set in Step 2)
    ▶zWhen multiple projectors are all controlled by group unit
    When controlling multiple projectors by group unit via RS-232C, perform the following settings.
    1) Set a different ID for each projector
    2)  
    Set [RESPONSE(ID GROUP)] to [ON] in only one projector
    3)
    
     
    Set [RESPONSE(ID GROUP)] to [OFF] for all other projectors set in Step 2)
    Note
     z There will be no response if 2 or more projectors have [RESPONSE(ID 
    ALL)] set to [ON].
     zT
    
    here will be no response if 2 or more projectors of the same group have [RESPONSE(ID GROUP)] set to [ON].
     zWhen setting multiple groups, set [RESPONSE(ID 
    
    ALL)] to [ON] in only one projector in each group.
    ▶■Cable specification
    ▶z
    When connected to a computer▶zWhen multiple projectors are connected
    Projector
    ( 
    terminal)
    1 NC NC 1
    Computer
    (DTE 
    specifications) Projector 1
    ( 
    terminal)
    1 NC NC 1
    Projector 2
    ( 
    terminal)
    2
    2 22
    3 3 33
    4 NC NC 4 4 NC NC 4
    5 5 55
    6 NC NC 6 6 NC NC 6
    7 7 77
    8 8 88
    9 NC NC 9 9 NC NC 9 
    						
    							Technical information
    170 - ENGLISH
    Appendix
    ▶■Control command
    The following table lists the commands that can be used to control the projector using a computer
    .
    ▶zProjector control command
    CommandDetails
    Remarks (parameters)
    PON Power on To check if the power is on, use the “Power query” command.
    POF Power standby
    QPW Power query 000 = Standby 001 = Power on
    IIS Switching the input 
    signal VID=VIDEO RG1 = RGB1 RG2 = RGB2 DVI=DVI-D HD1 = HDMI
    SD1 = SDI 1 (only for PT-DZ21KU, PT-DS20KU)
    SD2 = SDI 2 (only for PT-DZ21KU, PT-DS20KU)
    QSL Query for active 
    lamp selection 0 = Quad
    4 = Lamp 1/2/3
    8 = Triple 
    *1
    12 = Lamp 41 = Lamp 1/4
    5 = Lamp 1/2/4
    9 = Lamp 1
    13 = Single *1
    2 = Lamp 2/3
    6 = Lamp 1/3/4
    10 = Lamp 2
    3 = Dual *1
    7 = Lamp 2/3/4
    11 = Lamp 3
    LPM Lamp mode 0 = Quad
    4 = Lamp 1/2/3
    8 = Triple 
    *1
    12 = Lamp 41 = Lamp 1/4
    5 = Lamp 1/2/4
    9 = Lamp 1
    13 = Single *1
    2 = Lamp 2/3
    6 = Lamp 1/3/4
    10 = Lamp 2
    3 = Dual *1
    7 = Lamp 2/3/4
    11 = Lamp 3
    Q$L Lamp cumulative 
    operating time query 1 = Lamp 1 2 = Lamp 2 3 = Lamp 3 4 = Lamp 4
    Response is 0000 to 2000
    OSH Shutter 0 = End1 = Execute
    QSH Shutter status query 0 = End 1 = Execute
    VSE Aspect switching 0 = Standard/ VID auto
    1=4:32=16:95 = THROUGH
    6 = HV FIT 9 = H FIT 10 = V FIT
    QSE Aspect setting query 0 = Standard/ VID auto
    1=4:32=16:95 = THROUGH
    6 = HV FIT 9 = H FIT 10 = V FIT
    OPP P IN P execute 0 = Off 1 = User 1 2 = User 2 3 = User 3
    QPP P IN P setting query 0 = Off 1 = User 1 2 = User 2 3 = User 3
    OCS Sub memory 
    switching 01 to 96 = Sub memory number
    QSB Sub memory status 
    query 01 to 96 = Sub memory number
    *1:
     
    Used from the lamp with the shortest cumulative operating time.
    ▶z Projector control command (with sub command)
    Command
    Sub command Details Notes
    VXX RYCI1  RGB1 input setting +00000=RGB/YP
    BPR, +00001 = Y/C
    ▶zLens control command
    Command
    Sub command Details Notes
    VXX LNSI2 Lens H shift
    +00000 = Fine tuning 1+, +00001 = Fine tuning 1–, 
    +00100 = Fine tuning 2+, +00101 = Fine tuning 2–, 
    +00200 = Coarse adjustment+, +00201 = Coarse 
    adjustment–
    VXX
    LNSI3 Lens V shift
    VXX LNSI4 Lens focus
    VXX LNSI5 Lens zoom 
    						
    All Panasonic manuals Comments (0)