Home > Sharp > Air Conditioner > Sharp Cv10ctxw Manual

Sharp Cv10ctxw Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Sharp Cv10ctxw Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 615 Sharp manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							EN-19
    ENGLISH
    Point the remote control towards the units signal receiver window and press the desired button. A beep will sound when the unit receives the signal.
    •	 Make	sure	nothing,	such	as	curtains,	blocks the signal receiver window.
    •	For good reception of signal, the distance between operator and the unit should be no more than 5 meters.
    CAUTION
    •	 Do	not	expose	the	signal	receiver	window	to	direct	sunlight.	This	may	adversely affect its operation. If necessary, close the curtains to block out the sunlight.
    •	 Use	of	a	fluorescent	lamp	in	the	same	room	may	interfere	with	transmission	of the signal.
    •	 The	unit	may	be	affected	by	signals	emitted	from	other	remote	controllers	for	televisions,	VCRs	or	other	equipment	used	in	the	same	room.
    •	 Do	not	leave	the	remote	control	exposed	to	direct	sunlight	or	near	a	heater.	Protect the remote control from moisture and shock which can discolor or damage it.  
    						
    							EN-20
    OPERATION OF WIRELESS REMOTE CONTROL
    Notice: This is a general use remote controller, it could be used for the air 
    conditioners with multifunction.
    •	 Names	and	functions	of	wireless	remote	control Note: Be sure that there are no obstructions between receiver and remote controller; Don't	drop	or	throw	the	remote	control;	Don't	let	any	liquid	in	the	remote	control	and	put the remote control directly under the sunlight or any place where is very hot. 
    ON/OFF buttonON/OFF
    Remote control
    Signal transmitter
    AUTO
    COOLDRY
    FAN
    HEAT (HEAT mode is not available
    on this unit) 
    Fan 2
    Fan 1
    Fan 3 Fan 4
    MODE buttonMODE
    SLEEP buttonSLEEP
    FAN buttonFAN
    AUTO
    COOLDRY
    FAN
    HEAT
    .
    AUT O
    •  Press this button, Sleep On and Sleep Off can be selected. After powered on,Sleep Off is defaulted. After the unit is turned off, the Sleep function is cancelled. After Sleep function set up, the signal of Sleep will 
    display. 
    Under Fan and Auto modes, this function is 
    not available. 
    •  By pressing this key,you may  select  AUTO, FAN 
    1, FAN 2, FAN 3 or FAN 4, and may also cycle 
    between them. FAN 4 only in cool mode. After 
    being powered on, AUTO is defaulted. Only 
    LOW fan can be set under DRY mode, pressing 
    this key can not adjust the fan speed, but can 
    send message.
      (Note: When select Fan 4, the fan speed is same  as fan3 on this unit)
      
    • Press this button, the unit will be turned on, press it once more, the unit will be turned off. When turning on or turning off the unit, the Timer, Sleep function will be cancelled, but the presetting time still remains. 
    • Press this button, Auto, Cool, Dry 
    (Dehumidification), Fan mode can be 
    selected circularly. Auto mode is 
    default while power on. Under Auto 
    mode, the temperature will not be 
    displayed; (Under Heatmode, the 
    i
    nitial value is 28ºC (82ºF)); Under other modes, the initial value is 25ºC (77ºF).  
    ON/OFF MODE
    FAN
    SLEEP TIMER+
    -
    AUTO
    COOL
    DRY
    FAN T-ON
    T-OFF
    SLEEP
    LOCK
    SPEED 
    						
    							EN-21
    ENGLISH
    Remote control
    + button+
    - button-
    TIMER buttonTIMER
    ON/OFFMODE
    FAN
    SLEEP TIMER+
    -
    AUTO
    COOL
    DRY
    FANT-ON
    T-OFFSLEEP
    LOCK
    SPEED
    •  For presetting temperature increasing. 
    Press this button, to set up the 
    temperature, when unit is on . Continu-
    ously press and hold this button for 
    more than 2 seconds, the correspond-
    ing contents will be changed rapidly, 
    until unpress the button then send the 
    information, Cº (ºF) is displaying all 
    along. In Auto mode, the temperature 
    can not be set up, but operate this 
    button can send the signal. Centigrade 
    setting range :16-30; Fahrenheit setting 
    range 61-86. •  By pressing this key under switch-off state, 
    you may set the time for auto switch-on. The 
    range of setting is 0.5 ~ 24 hours. The 
    characters "T-ON" and "H" will flash for 5  
    seconds. Within 5 seconds, you may make 
    one press of this key to complete the setting 
    and send the message.If the setting is valid, 
    the set time will be displayed for 2 seconds 
    before display of the temperature message. 
    During flash,you may press "+" key to 
    increase the value and press "-" key to 
    decrease the value. The time will increase or 
    decrease by 0.5 hours with each press of this 
    key.If pressing "+" or "-" key continuously, 
    the time value will change rapidly. The 
    remote controller can increase the set time 
    by 0.5 hours every 0.25 seconds. After being 
    powered on, the fault is no timer setting, and 
    there is no display of "T-ON" or "H". Press 
    ON/OFF key to switch on the unit and cancel 
    the auto switch-on.When the temperature 
    display becomes constant, you may press 
    this key again to display the remaining set 
    time. The time value, "T-On" and "H" will 
    display constantly for 2 seconds. After 2 
    seconds,the preset temperature will be 
    displayed within these 2 seconds, you may 
    press this key again to cancel the auto 
    switch-on and send the message. 
    •  By pressing this key under switch-on state,  set the time for auto switch-off.
            
       
    •  Presetting temperature can be  decreased. Press this button, the 
    temperature can be set up, continu-
    ously press this button and hold for two 
    seconds, the relative contents can 
    quickly change, until unhold this button 
    and send the order that the ºC (ºF) 
    signal will be displayed all the time. The 
    temperature adjustment is unavailable 
    under the Auto mode, but the order can 
    be sent by if pressing this button.  
    						
    							EN-22
    OPERATION OF WIRELESS REMOTE CONTROL
    Guide for operation- General operation
    1. After powered on, press ON/OFF button, the unit will start to run.
    2.	Press	MODE	button,	select	desired	running	mode, enter into the corresponding operation directly.
    3.	Pressing	+	or	-	button,	to	set	the	desired	temperature.	(It	is	unnecessary	set	the	temp.	at	AUTO	mode.)
    4. Pressing FAN button, set fan speed, can select AUTO,	FAN	1,	FAN	2,	FAN	3	or	FAN	4.	(Note:	When	select	Fan	4,	the	fan	speed	is	same	as	fan	3	on	this	unit)
    Guide for operation- Optional operation
    1. Press SLEEP button, to set sleep.
    2. Press TIMER button, can set the scheduled timer on or timer off.
    Introduction for special function
    •	 About	AUTO	RUN	 When	AUTO	RUN	mode	is	selected,	the	setting	temperature	will	not	be	displayed	on	the	LCD,	the unit will be in accordance with the room temp. automatically to select the suitable running method.
    •	 About	LOCK Under	switch-on	or	switch-off	state,	you	may	hold	"+"	and	"-"	key	simultaneously	to	lock	and	unlock	the	keypad.	When	locked,	the	display	will show the LOCK icon, in which case the lock icon	will	flash	three	times	upon	operation	of	any key. After the keypad is unlocked, the lock icon on the display will be hidden. After initially powering on, the default is unlock.
    •	 About	switch	between	Fahrenheit	and	Centigrade Under	switch-off	state,	you	may	hold	"-"	and	"MODE"	keys	simultaneously	to switch between ºC and ºF.
    •	 About	Lamp	 Under	switch-on	or	switch-off	state,	you	may	hold	"+"	and	"FAN"	key	simultaneously	for	3	seconds to set the lamp on or off and send the code. After initially powering on, the lamp is defaulted on.
    ON/OFFMODE
    FAN
    SLEEP TIMER+
    -
    12
    ON/OFF
    MODE
    FAN
    SLEEP TIMER+
    -1
    3
    4
    2 
    						
    							EN-23
    ENGLISH
    MAINTENANCE
    •	 Changing	batteries	and	notices
    1. Slightly to press the place to take out the back cover of wireless remote control.(As	shown	in	figure)
    2. Take	out	the	old	batteries.	(As	show	in	figure)
    3. Insert	two	new	AAA1.5V	dry	batteries,	and	pay	attention	to	the	polarity.	(As	show	in	figure)
    4. Attach the back cover of wireless remote	control.	(As	show	in	figure
    NOTE: 
    •	 When	changing	the	batteries,	do	not	use	old or different batteries, otherwise, it can cause the malfunction of the wireless remote control.
    •	 If	the	wireless	remote	control	will	not	be used for a long time, please take them	out,	and	don't	let	the	leaking	liquid	damage the wireless remote control.
    •	 The	operation	should	be	in	its	receiving	range.
    •	 It	should	be	placed	at	where	is	1m	away	from	the	TV	set	or	stereo	sound	sets.
    •	 If	the	wireless	remote	control	cannot	operate normally, please take them out, after 30 seconds later and reinsert, if they cannot normally run, please change them.
    .
    1
    3
    4
    2  
    						
    							EN-24
    Gas
    12
    2
    MAINTENANCE
    Mobile AC  
    There are wheels at bottom of mobile air conditioner that enable the unit moves \
    among rooms conveniently according to need.
    Warning	  Plug off power plug from socket and cut off power before any maintenance to prevent electric shock or damage to units.
    Clean air filter   If too much dust collected on filter, performance of air conditioner will reduce, thus it is better to clean filter at least once 2 weeks.
    Note:   
    Disassembly	 From	these	two	direction	to	take	out	filters.
    Wash	Clean	filter	individually,	When	cleaning,	wash	it	by	shooting	water	(for	example	shower)	and	shakes	it.	Or	soak	it	in	warm	soap	water	then	dry	it.
    Clean	AC	 Please	soak	the	cloth	by	warm	whose	temperature	is	lower	than	40º	C	(104	ºF)	 (or	soap	water	or	water	with	proper	cleaner)	and	wipe	the	dirty	part	on	unit	slightly	after	the	cloth	is	wrung.	Don't	clean	the	unit	by	gasoline,	diesel	oil	or	similar substance. Pull out the power plug before cleaning. 
    						
    							EN-25
    ENGLISH
    MALFUNCTION ANALYSIS
    If malfunction occur, please check the following before maintenance:
    TroublesPossible CausesSolutions
    The air conditioner doesn't	start.The power supply is not connected well.
    The power plug is not inserted tightly.
    There is the malfunction of power plug or socket.
    The fuse is broken.
    1. Insert the power plug tightly.
    2. Replace the power plug or socket.
    3. Ask for the maintenance man to replace the fuse.
    Although it was set to COOL mode, there is no cool wind.
    1. The room temperature is lower than the set temp.
    2. The evaporator frosts.
    1. This is the normal phenomenon.	Unit	is	running	in defrosting operation, it will resume running in original operation after defrosting.
    Although it was set the DRY	mode,	there	is	no	cool wind.
    The evaporator frosts.1.	Unit	is	running	in	defrosting	operation, it will resume running in original oration after defrosting.
    The	LED	displays	"".Low voltage over current protection.Cut off power supply, after 10 minutes, turn on the unit, if " still be displays, please inform the maintenance man to maintain.
    The	LED	displays"".The water tank gets full.Pour out water in the tank
    The	LED	displays"".Malfunction of Ambient temperature sensor.Check if indoor room temperature sensor is connected properly 
    The	LED	displays"".Malfunction of evaporator temperature sensor.Check if the evaporator temperature is connected properly.  
    						
    							EN-26
    SAFETY NOTICE
    Location		Don't	place	the	unit	in	narrow	location.	Guarantee	better	ventilation	for	unit	to	prevent malfunction occurs. 
    	Don't	place	the	unit	in	where	there	is	direct	sunburn	to	prevent	fade	and	reduce	of effect.
    	The	unit	should	be	at	least	50cm	away	from	surface	of	flammable	thing.
    	Don't	soak	the	unit	or	operateit	in	place	where	is	easyto	get	wet	to	prevent	creepage.
    	Don't	operate	the	unit	in	following	location	for	malfunction	may	be	led:
    	*Gas	place	*Fire*	where	is	easy	to	get	oil.
    Others: Consider safe problem to following people.
    	1)	Children	and	patients.
    	2)	Sick	people	or	who	cannot	express	himself	or	herself.
    	3)	Those	who	are	exhausted,	badly	drunk	or	taken	lot	of	soporific.
    	Don't	climb	on	the	unit	or	place	something	on	it	for	drop	may	occur	and	leading	malfunction.
    	Don't	let	wind	blows	to	human	directly	for	long	time	for	it	is	not	good	for	health.
    	The	unit	should	leave	TV	for	at	least	l	m	to	prevent	disturbance	of	electromagnetic wave.
    	Don't	block	air	inlet	or	outlet	vent	for	it	would	lead	malfunction.
    	Don't	insert	finger	or	stick	etc.	into	air	outlet	vent;	take	special	care	to	children	to prevent accidence.
     It is forbidden to slope or turn down air conditioner. Take off power plug immediately if abnormal circumstance occurs and contact the authorized seller for check and repair.
    	Don't	sprinkle	and	shower	unit	by	insecticide	for	it	will	lead	deformation	or	breakage
     If your air conditioner has problems on quality or others, please contact local seller. 
    						
    							EN-27
    ENGLISH
    MALFUNCTION ANALYSIS
    For disposal there are several possibilities:
    a)	The	municipality	has	established	collection	systems,	where	electronic	waste	can	be	disposed	of	at least free of charge to the user.
    b)	When	buying	a	new	product,	the	retailer	will	take	back	the	old	product	at	least	free	of	charge.
    c)	The	manufacturer	will	take	back	the	old	appliance	for	disposal	at	least	free	of	charge	to	the	user.
    d)	As	old	products	contain	valuable	resources,	they	can	be	sold	to	scrap	metal	dealers.	Wild	disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.
    DISPOSAL:	Do	not	dispose	this	product	as	unsorted	municipal waste. Collection of such waste separately for special treatment is necessary.
    If any quality problems or any other problems exist, please contact with the local dealer.
    AFTER SALES SERVICE   
    						
    All Sharp manuals Comments (0)