    							MX-2300/2700 N/G  SIMULATION  7 – 45
     
    43
     
    43-1
    Purpose: Setting
    Function (Purpose): Used to set the fusing temperature in each
    operation mode.
    Section:Fusing
    Item: Operation
    Operation/Procedure
    1) Select the set item with [↑] and [↓] buttons.
    The highlighted set value is switched and the value is dis-
    played in the setting area.
    * If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.
    If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.
    2) Enter the set value with 10-key.
    * Press [C] key to clear the entered values.
    3) When [OK] button is pressed, the currently entered data are
    saved to EEPROM and RAM.
    * When [↑], [↓] button, [COLOR], or [BLACK] key is pressed,
    the current set values is saved in EEPROM and RAM.
    *1: Japan, China, AB_B
    *2: U.S.A, Canada, Europe, U.K, Australia, Inch, AB_A
     
    43-4
    Purpose:Setting
    Function (Purpose): Used to set the fusing temperature in each
    operation mode. (Continued from 43-01.)
    Section:Fusing
    Item: Operation
    Operation/Procedure
    1) Select the set item with [↑] and [↓] buttons.
    The highlighted set value is switched and the value is dis-
    played in the setting area.
    * If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.
    If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.
    2) Enter the set value with 10-key.
    * Press [C] key to clear the entered values.
    3) When [OK] button is pressed, the currently entered data are
    saved to EEPROM and RAM.
    When setting is completed, [OK] button returns to the normal
    display.
    * When [↑], [↓], [COLOR], or [BLACK] key is pressed, the current
    set value is saved to EEPROM and RAM.
    Item Display ContentSet 
    rangeDefault value
    Group 
    A *1Group 
    B *2
    A HL_UM  READY TH_UM set value in 
    READY standby70 to 
    230175 180
    B HL_LM READY TH_LM set value in 
    READY standby30 to 
    200105 105
    C HL_US READY TH_US set value in 
    READY standby70 to 
    230155 160
    D HL_UM PLAIN 
    PAPER BWBW normal paper 
    TH_UM set value70 to 
    230170 175
    E HL_LM PLAIN 
    PAPER BWBW normal paper 
    TH_LM set value30 to 
    200130 130
    F HL_US PLAIN 
    PAPER BWBW normal paper 
    TH_US set value70 to 
    230180 180
    G HL_UM PLAIN 
    PAPER CLCOLOR normal 
    paper TH_UM set 
    value70 to 
    230170 175
    H HL_LM PLAIN 
    PAPER CLCOLOR normal 
    paper TH_LM set 
    value30 to 
    200130 130
    I HL_US PLAIN 
    PAPER CLCOLOR normal 
    paper TH_US set 
    value70 to 
    230180 180
    J WARMUP 
    FUMON 
    HL_UM TFusing paper front 
    rotation start 
    TH_UM set value30 to 
    200145 145
    K WARMUP 
    FUMOFF 
    HL_LM TFusing paper front 
    rotation start 
    TH_LM set value30 to 
    20075 75
    LWARM UP 
    END TIMEWARM UP 
    complete time30 to 
    25576 76
    M HL_UM HEAVY 
    PAPERHeavy paper 
    TH_UM set value70 to 
    230170 170
    N HL_LM HEAVY 
    PAPERHeavy paper 
    TH_LM set value30 to 
    200140 140
    O HL_US HEAVY 
    PAPERHeavy paper 
    TH_US set value70 to 
    230175 175
    PHL_UM OHP 
    PAPEROHP-TH_UM set 
    value70 to 
    230170 170
    Q HL_LM OHP 
    PAPEROHP-TH_LM set 
    value30 to 
    200145 145
    R HL_US OHP 
    PAPEROHP-TH_US set 
    value70 to 
    230170 170
    S HL_UM ENV 
    PAPEREnvelope TH_UM 
    set value70 to 
    230180 180
    T HL_LM ENV 
    PAPEREnvelope TH_LM 
    set value30 to 
    200145 145
    UHL_US ENV 
    PAPEREnvelope TH_US 
    set value70 to 
    230180 180
    VHL_UM E-
    STARTH_UM set value 
    when preheating30 to 
    200145 142
    W TH_US E-
    STARTH_US set value 
    when preheating30 to 
    200130 130
    X PRE-JOB TH_UM set value 
    when resetting from 
    preheating30 to 
    200160 160
    TH_UM Fusing upper thermister main
    TH_LM Fusing lower thermister main
    TH_US Fusing upper thermister sub
    HL_UM Heater lamp upper main
    HL_LM Heater lamp lower main
    HL_US Heater lamp upper subItem Display ContentSet 
    rangeDefault value
    Group 
    A *1Group 
    B *2
    0
    A:A9æ180
    B9æ105
    C9æ160
    D9æ1759çHL_UM READY
    9çHL_LM READY
    9çHL_US READY
    9çHL_UM PLAINPA P E RBW
    SIMULATIONNO.439Ù01
    FUSER TEMP SETUP FOR PAPER
    180
    :70:*230:	
    OK
    TESTCLOSE 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 46 
    *1: Japan, China, AB-B
    *2: U.S.A, Canada, Europe, U.K, Australia, Inch, AB_A
     
    43-20
    Purpose: Setting
    Function (Purpose): Used to correct the environments of low
    temperature and low humidity (L/L) for the
    fusing temperature setting 1 for each paper
    (SIM 43-01).
    Section:Fusing
    Item: Operation
    Operation/Procedure
    1) When the machine enters Simulation 43-20, the screen on the
    right is displayed. (The current set value is displayed.)
    2) Select the set item with [↑] and [↓] buttons.
    The highlighted section of the set value is switched and dis-
    played on the set setting area.
    * If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.
    3) Enter the set value with 10-key.
    * Press [C] key to clear the entered values.
    4) When [OK] button is pressed, the currently entered data are
    saved to EEPROM and RAM.
    * When [↑], [↓], [COLOR], or [BLACK] key is pressed, the cur-
    rent set value is saved to EEPROM and RAM.
    * Input value: The intercept for the correction value is 50. This is
    because the set value is kept as a positive number in case of a
    negative setting due to negative correction.
    • Correction value: (–49 to +49) Input value: Actually entered value
    (1 to 99)
    
    Item Display ContentSet 
    rangeDefault value
    Group 
    A *1Group 
    B *2
    A HL_UM PLAIN 
    PAPER BW 
    DUPBW plain paper 
    duplex TH_UM 
    set value70 to 230 170 175
    B HL_LM PLAIN 
    PAPER BW 
    DUPBW plain paper 
    duplex TH_LM 
    set value30 to 200 100 100
    C HL_US PLAIN 
    PAPER BW 
    DUPBW plain paper 
    duplex TH_US 
    set value70 to 230 175 180
    D PLAIN PAPER 
    BW DUP APP 
    CNTBW plain paper 
    duplex applicable 
    number of sheets0 to 60 1 1
    E HL_UM PLAIN 
    PAPER CL 
    DUPCOLOR plain 
    paper duplex 
    TH_UM set value70 to 230 170 175
    F HL_LM PLAIN 
    PAPER CL 
    DUPCOLOR plain 
    paper duplex 
    TH_LM set value30 to 200 100 100
    G HL_US PLAIN 
    PAPER CL 
    DUPCOLOR plain 
    paper duplex 
    TH_US set value70 to 230 175 180
    H PLAIN PAPER 
    CL DUP APP 
    CNTCOLOR plain 
    paper duplex 
    applicable 
    number of sheets0 to 60 1 1
    TH_UM Fusing upper thermister main
    TH_LM Fusing lower thermister main
    TH_US Fusing upper thermister sub
    HL_UM Heater lamp upper main
    HL_LM Heater lamp lower main
    HL_US Heater lamp upper sub
    0
    A:
    A:170
    B: 100
    C: 175
    D: 19çHL_UMPLAIN PAPER BW DUP
    9çHL_LM PLAIN PAPER BW DUP
    9çHL_US PLAIN PAPER BW DUP
    9çPLAIN PAPER BW DUP APP CNT
    SIMULATIONNO.43-04
    FUSER TEMP SETUP2 FOR PAPER
    170
    :70:*230:	
    OK
    TESTCLOSE
    Correction value –49 –25 –5 0 +5 +25 +49
    Input value 1 25 45 50 55 75 99
    Item Display item Item contentSet 
    rangeDefault 
    value
    A HL_UM READY 
    LLCorrection value for 
    TH_UM set value in Ready 
    standby under LL 
    environment1 to 99 55
    B HL_LM READY 
    LLCorrection value for TH_LM 
    set value in Ready standby 
    under LL environment1 to 99 55
    C HL_US READY 
    LLCorrection value for TH_US 
    set value in Ready standby 
    under LL environment1 to 99 55
    D HL_UM PLAIN 
    BW LLCorrection value for BW 
    plain paper TH_UM set 
    value under LL 
    environment1 to 99 55
    E HL_LM PLAIN 
    BW LLCorrection value for BW 
    plain paper TH_LM set 
    value under LL 
    environment1 to 99 55
    F HL_US PLAIN 
    BW LLCorrection value for BW 
    plain paper TH_US set 
    value under LL 
    environment1 to 99 55
    G HL_UM PLAIN 
    CL LLCorrection value for 
    COLOR plain paper 
    TH_UM set value under LL 
    environment1 to 99 55
    H HL_LM PLAIN 
    CL LLCorrection value for 
    COLOR plain paper TH_LM 
    set value under LL 
    environment1 to 99 55
    I HL_US PLAIN 
    CL LLCorrection value for 
    COLOR plain paper TH_US 
    set value under LL 
    environment1 to 99 55
    JWARMUP 
    FUMON 
    HL_UM T LLCorrection value for fusing 
    motor front rotation start 
    TH_UM set value under LL 
    environment1 to 99 60
    KWARMUP 
    FUMOFF 
    HL_LM T LLCorrection value for fusing 
    motor front rotation start 
    TH_LM set value under LL 
    environment1 to 99 55
    L WARMUP END 
    TIME LLCorrection value for 
    WARMUP complete time 
    under LL environment1 to 99 80
    M HL_UM HEAVY 
    LLCorrection value for heavy 
    paper TH_UM set value 
    under LL environment1 to 99 60
    N HL_LM HEAVY 
    LLCorrection value for heavy 
    paper TH_LM set value 
    under LL environment1 to 99 60 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 47 
     
    43-21
    Purpose: Setting
    Function (Purpose): Used to perform correction of high temper-
    ature and high humidity (H/H) environment
    for the fusing temperature setting 1 (SIM
    43-01) for each paper.
    Section:Fusing
    Item: Operation
    Operation/Procedure
    1) When the machine enters SIM 43-21, the following screen is
    displayed. (The current set value is displayed.)
    2) Select the set item with [↑] and [↓] buttons.The highlighted section of the set value is switched and dis-
    played on the set setting area.
    * If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.
    If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.
    3) Enter the set value with 10-key.
    * Press [C] key to clear the entered values.
    4) When [OK] button is pressed, the currently entered data are
    saved to EEPROM and RAM.
    * When [↑], [↓], [COLOR], or [BLACK] key is pressed, the current
    set value is saved to EEPROM and RAM.
    * Input value: The intercept for the correction value is 50. This is
    because the set value is kept as a positive number in case of a
    negative setting due to negative correction.
    • Set value: Value to be set (–49 to +49), Input value: Actual input
    (1 to 99)
    
    O HL_US HEAVY 
    LLCorrection value for heavy 
    paper TH_US set value 
    under LL environment1 to 99 60
    P HL_UMOHP LL Correction value for OHP 
    TH_UM set value under LL 
    environment1 to 99 60
    Q HL_LM OHP LL Correction value for OHP 
    TH_LM set value under LL 
    environment1 to 99 60
    R HL_US OHP LL Correction value for OHP 
    TH_US set value under LL 
    environment1 to 99 60
    S HL_UM 
    ENVELOPE LLCorrection value for 
    ENVELOPE TH_UM set 
    value under LL 
    environment1 to 99 60
    T HL_LM 
    ENVELOPE LLCorrection value for 
    ENVELOPE TH_LM set 
    value under LL 
    environment1 to 99 60
    U HL_US 
    ENVELOPE LLCorrection value for 
    ENVELOPE TH_US set 
    value under LL 
    environment1 to 99 60
    V HL_UM E-STAR 
    LLCorrection value for 
    preheating TH_UM set 
    value under LL 
    environment1 to 99 60
    W HL_US E-STAR 
    LLCorrection value for 
    preheating TH_US set 
    value under LL 
    environment1 to 99 60
    X PRE-JOB LL Correction value for 
    TH_UM set value when 
    resetting from preheating 
    under LL environment1 to 99 60
    TH_UM Fusing upper thermister main
    TH_LM Fusing lower thermister main
    TH_US Fusing upper thermister sub
    HL_UM Heater lamp upper main
    HL_LM Heater lamp lower main
    HL_US Heater lamp upper subItem Display item Item contentSet 
    rangeDefault 
    value
    OK
    0
    A:
    A:55;HL_UMREADY LL
    SIMULATIONNO.43-20
    FUSERTEMPADJUSTMENT(LL)
    55
    :1:*99:	
    TEST
    B:55;HL_LMREADY LL
    C:55;HL_USREADY LL
    D:55;HL_UMPLAIN BW LL
    CLOSE
    Set value –49 –25 –5 0 +5 +25 +49
    Input value 1 25 45 50 55 75 99
    Item Item display Content of itemSet 
    rangeDefault 
    value
    A HL_UM READY 
    HHCorrection value for 
    TH_UM set value in 
    READY standby under 
    HH environment1 to 99 45
    B HL_LM READY 
    HHCorrection value for 
    TH_LM set value in 
    READY standby under 
    HH environment1 to 99 45
    C HL_US READY 
    HHCorrection value for 
    TH_US set value in 
    READY standby under 
    HH environment1 to 99 45
    D HL_UM PLAIN 
    BW HHCorrection value for BW 
    plain paper TH_UM set 
    value under HH 
    environment1 to 99 45
    E HL_LM PLAIN 
    BW HHCorrection value for BW 
    plain paper TH_LM set 
    value under HH 
    environment1 to 99 45
    F HL_US PLAIN 
    BW HHCorrection value for BW 
    plain paper TH_US set 
    value under HH 
    environment1 to 99 45
    G HL_UM PLAIN 
    CL HHCorrection value for 
    COLOR plain paper 
    TH_UM set value under 
    HH environment1 to 99 45
    H HL_LM PLAIN 
    CL HHCorrection value for 
    COLOR plain paper 
    TH_LM set value under 
    HH environment1 to 99 45
    I HL_US PLAIN 
    CL HHCorrection value for 
    COLOR plain paper 
    TH_US set value under 
    HH environment1 to 99 45
    J WARMUP 
    FUMON HL_UM 
    T HHCorrection value for 
    fusing motor front rotation 
    start TH_UM set value 
    under HH environment1 to 99 50
    K WARMUP 
    FUMOFF HL_LM 
    T HHCorrection value for 
    fusing motor front rotation 
    end TH_UM set value 
    under HH environment1 to 99 50 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 48 * WARMUP END TIME HH → 1s change by 1 count
    The other correction values → 1°C change by 1 count
    
     
    43-22
    Purpose:Setting
    Function (Purpose): Used to perform L/L (low temperature, low
    humidity) correction for the fusing tempera-
    ture setting 1 (SIM 43-04) for each paper.
    Section:Fusing
    Item: Operation
    Operation/Procedure
    1) When the machine enters Simulation 43-22, the following
    screen is displayed. (The current set value is displayed.)
    2) Select the set item with [↑] and [↑] buttons.
    The highlighted set value is switched and the value is dis-
    played in the setting area.
    * If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.
    If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.
    3) Enter the set value with 10-key.
    * Press [C] key to clear the entered values.
    4) When [OK] button is pressed, the currently entered data are
    saved to EEPROM and RAM.
    * When [↑], [↑], [COLOR], or [BLACK] key is pressed, the current
    set value is saved to EEPROM and RAM.
    * Input value: The intercept for the correction value is 50. This is
    because the set value is kept as a positive number in case of a
    negative setting due to negative correction.
    • Set value: Value to be set (–49 to +49)
    Input value: Actual input value (1 to 99)
    
    L WARMUP END 
    TIME HHCorrection value for 
    WARMUP end time under 
    HH environment1 to 99 50
    M HL_UM HEAVY 
    HHCorrection value for 
    heavy paper TH_UM set 
    value under HH 
    environment1 to 99 50
    N HL_LM HEAVY 
    HHCorrection value for 
    heavy paper TH_LM set 
    value under HH 
    environment1 to 99 50
    O HL_US HEAVY 
    HHCorrection value for 
    heavy paper TH_US set 
    value under HH 
    environment1 to 99 50
    P HL_UM OHP HH Correction value for OHP 
    TH_UM set value under 
    HH environment1 to 99 50
    Q HL_LM OHP HH Correction value for OHP 
    TH_LM set value under 
    HH environment1 to 99 50
    R HL_US OHP HH Correction value for OHP 
    TH_US set value under 
    HH environment1 to 99 50
    SHL_UM 
    ENVELOPE HHCorrection value for 
    ENVELOPE TH_UM set 
    value under HH 
    environment1 to 99 50
    T HL_LM 
    ENVELOPE HHCorrection value for 
    ENVELOPE TH_LM set 
    value under HH 
    environment1 to 99 50
    UHL_US 
    ENVELOPE HHCorrection value for 
    ENVELOPE TH_US set 
    value under HH 
    environment1 to 99 50
    V E-STAR HH Correction value for 
    preheating TH_UM set 
    value under HH 
    environment1 to 99 50
    W HL_US E-STAR 
    HHCorrection value for 
    preheating TH_US set 
    value under HH 
    environment50
    X PRE-JOB HH Correction value for 
    TH_UM set value when 
    resetting from preheating 
    under HH environment1 to 99 50
    TH_UM Fusing upper thermister main
    TH_LM Fusing lower thermister main
    TH_US Fusing upper thermister sub
    HL_UM Heater lamp upper main
    HL_LM Heater lamp lower main
    HL_US Heater lamp upper subItem Item display Content of itemSet 
    rangeDefault 
    value
    OK
    0
    A:
    A: 459çHL_UM READY HH
    SIMULATION NO.43-21
    FUSER TEMP ADJUSTMENT (HH)
    45
    [1:*99]
    TEST
    B459çHL_LM READY HH
    C459ç
    HL_US READY HH
    D459çHL_UM PLAIN BW HH
    CLOSE
    Set value –49 –25 –5 0 +5 +25 +49
    Input value 1 25 45 50 55 75 99
    Item Display item Item contentSet 
    rangeDefault 
    value
    A HL_UM PLAIN 
    BW DUP LLCorrection value for upper 
    TH_UM BW plain paper 
    duplex under LL 
    environment1 to 99 60
    B HL_LM PLAIN 
    BW DUP LLCorrection value for lower 
    TH_LM BW plain paper 
    duplex under LL 
    environment1 to 99 60
    C HL_US PLAIN 
    BW DUP LLCorrection value for upper 
    TH_US BW plain paper 
    duplex under LL 
    environment1 to 99 60
    D PLAIN BW DUP 
    APP CNT LLCorrection value for BW 
    plain paper duplex 
    applicable number of 
    sheets under LL 
    environment1 to 99 50
    E HL_UM PLAIN 
    CL DUP LLCorrection value for upper 
    TH_UM COLOR plain 
    paper duplex under LL 
    environment1 to 99 60
    F HL_LM PLAIN CL 
    DUP LLCorrection value for upper 
    TH_LM COLOR plain 
    paper duplex under LL 
    environment1 to 99 60
    G HL_US PLAIN CL 
    DUP LLCorrection value for upper 
    TH_US COLOR plain 
    paper duplex under LL 
    environment1 to 99 60 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 49 * PLAIN BW DUPCNT LL, PLAIN CL DUPCNT LL, HEAVY BW
    DUP APCNT LL, HEAVY CL DUP APCNT LL → 1s change by 1
    count
    The other correction values → 1°C change by 1 count
    
     
    43-23
    Purpose: Setting
    Function (Purpose): Used to perform H/H (high temperature,
    high humidity) correction for the fusing tem-
    perature setting 1 (SIM 43-04) for each
    paper.
    Section:Fusing
    Item: Operation
    Operation/Procedure
    1) When the machine enters Simulation 43-23, the following
    screen is displayed. (The current set value is displayed.)
    2) Select the set item with [↑] and [↓] buttons.
    The highlighted set value is switched and the value is dis-
    played in the setting area.
    * If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.
    If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.
    3) Enter the set value with 10-key.
    * Press [C] key to clear the entered values.
    4) When [OK], [↑], [↓] button, [COLOR], or [BLACK] key is
    pressed, the currently entered data are saved to EEPROM and
    RAM.
    * Input value: The intercept for the correction value is 50. This is
    because the set value is kept as a positive number in case of a
    negative setting due to negative correction.
    • Set value: Value to be set (–49 to +49)
    Input value: Actual input value (1 to 99)
    * PLAIN BW DUPCNT HH, PLAIN CL DUPCNT HH, HEABY BW
    DUP APCNT HH, HEABY CL DUP APCNT HH → 1s change by
    1 count
    The other correction values → 1°C change by 1 count
    
    H PLAIN CL DUP 
    APP CNT LLCorrection value for 
    COLOR plain paper 
    duplex applicable number 
    of sheets under LL 
    environment1 to 99 50
    TH_UM Fusing upper thermister main
    TH_LM Fusing lower thermister main
    TH_US Fusing upper thermister sub
    HL_UM Heater lamp upper main
    HL_LM Heater lamp lower main
    HL_US Heater lamp upper sub
    Set value –49 –25 –5 0 +5 +25 +49
    Input value 1 25 45 50 55 75 99Item Display item Item contentSet 
    rangeDefault 
    value
    0
    A:
    A:609çHL_UM PLAIN BW DUPFUSSIMULATION NO.43-22
    60
    :1:*99:	
    TEST
    B:609çHL_LM PLAIN BW DUP
    C:609çHL_US PLAIN BW DUP
    D:509çPLAIN BW DUP APP CNT LL
    CLOSE
    OK
    Item Display item Item contentSet 
    rangeDefault 
    value
    A HL_UM PLAIN BW 
    DUP HHCorrection value for 
    TH_UM BW plain paper 
    duplex under HH 
    environment1 to 99 45
    B HL_LM PLAIN BW 
    DUP HHCorrection value for 
    TH_LM BW plain paper 
    duplex under HH 
    environment1 to 99 50
    C HL_US PLAIN BW 
    DUP HHCorrection value for 
    TH_US BW plain paper 
    duplex under HH 
    environment1 to 99 45
    D PLAIN BW DUP 
    APP CNT HHCorrection value for 
    BW plain paper duplex 
    applicable number of 
    sheets under HH 
    environment1 to 99 50
    E HL_UM PLAIN CL 
    DUP HHCorrection value for 
    TH_UM COLOR plain 
    paper duplex under HH 
    environment1 to 99 45
    F HL_LM PLAIN CL 
    DUP HHCorrection value for 
    TH_LM COLOR plain 
    paper duplex under HH 
    environment1 to 99 50
    G HL_US PLAIN CL 
    DUP HHCorrection value for 
    TH_US COLOR plain 
    paper duplex under HH 
    environment1 to 99 45
    H PLAIN CL DUP APP 
    CNT HHCorrection value for 
    COLOR plain paper 
    duplex applicable 
    number of sheets under 
    HH environment1 to 99 50
    TH_UM Fusing upper thermister main
    TH_LM Fusing lower thermister main
    TH_US Fusing upper thermister sub
    HL_UM Heater lamp upper main
    HL_LM Heater lamp lower main
    HL_US Heater lamp upper sub
    OK
    0
    A:
    A:45HL_UM PLAIN BW DUP HH
    SIMULATIONNO.43-23
    FUSER TEMP ADJUSTMENT (HH:DUP)
    45
    :1:*99:	
    TEST
    B:50HL_LM PLAIN BW DUP HH
    C:45HL_US PLAIN BW DUP HH
    D:50PLAIN BW DUP APP CNT HH
    CLOSE 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 50
     
    43-24
    Purpose: Setting
    Function (Purpose): Used to enter the correction values for SIM
    43-1 and SIM 43-4 temperature correc-
    tions.
    Section:Fusing
    Item: Operation
    Operation/Procedure
    1) Select the set item with [↑] and [↓] buttons.
    The highlighted section of the set value is switched and dis-
    played on the set setting area.
    * If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.
    If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.2) Enter the set value with 10-key.
    * Press [C] key to clear the entered values.
    3) When [OK], [↑], [↓] button, [COLOR], or [BLACK] key is
    pressed, the entered value is set.
    * Input value: The intercept for the correction value is 50. This is
    because the set value is kept as a positive number in case of a
    negative setting due to negative correction.
    • Set value: Value to be set (–49 to +49)
    Input value: Actual input value (1 to 99)
    
    * On adjustment values
    Each temperature correction value → Temperature 1°C change
    by 1 count
    Each paper exit count → 1 sheet by 1 count
    Each cool-down time → 1s change by 1 count
    
    Set value –49 –25 –5 0 +5 +25 +49
    Input value 1 25 45 50 55 75 99
    Item Display items Item descriptionsSet 
    rangeDefault 
    value
    A NN_120_ WUP_HL_UM & HL_US WARMUP end temperature 
    correction value120°C or below when turning 
    on the power under NN 
    environmentCommon to items 
    HL_UM, HL_US1 to 99 50
    B NN_120_WUP_HL_LMItem HL_LM 1 to 99 50
    C LL_120_WUP_HL_UM & HL_US 120°C or below when turning 
    on the power under LL 
    environmentCommon to items 
    HL_UM, HL_US1 to 99 50
    D LL_120_WUP_HL_LMItem HL_LM 1 to 99 50
    E HH_120_WUP_HL_UM & HL_US 120°C or below when turning 
    on the power under HH 
    environmentCommon to items 
    HL_UM, HL_US1 to 99 50
    F HH_120_WUP_HL_LMItem HL_LM 1 to 99 50
    G ON_120_WUP_HL_UM Temperature correction value 
    immediately after completion of 
    warm-up and during continuation 
    of temperature correction120°C or below when turning 
    on the powerItem HL_UM 1 to 99 40
    H ON 120 WUP HL_USItem HL_US 1 to 99 55
    I NN_120_ FUS_DUP_HL_UM & HL_US Fusing temperature correction 
    value120°C or below when turning 
    on the power under NN 
    environmentCommon to items 
    HL_UM, HL_US1 to 99 55
    J NN_120_ FUS_DUP_HL_LMItem HL_LM 1 to 99 50
    K LL_120_ FUS_DUP_HL_UM & HL_US 120°C or below when turning 
    on the power under LL 
    environmentCommon to items 
    HL_UM, HL_US1 to 99 60
    L LL_120_ FUS_DUP_HL_LMItem HL_LM 1 to 99 50
    M HH_120_ FUS_DUP_HL_UM & HL_US 120°C or below when turning 
    on the power under HH 
    environmentCommon to items 
    HL_UM, HL_US1 to 99 50
    N HH_120_ FUS_DUP_HL_LMItem HL_LM 1 to 99 50
    O NN_120_ FUS_DUP_CNT Fusing duplex paper exit count Under NN environment 1 to 60 5
    P LL_120_ FUS_DUP_CNT Under LL environment 1 to 60 10
    Q HH_120_ FUS_DUP_CNT Under HH environment 1 to 60 5
    R COOL_DOWN_HEAVY Cool-down time Heavy paper 1 to 60 15
    S COOL_DOWN_OHPOHP 1 to 60 30
    T COOL_DOWN_DEVELOPEnvelope 1 to 60 40
    U WUP DUP TIME Temperature correction 
    continuation time immediately 
    after completion of warm-up-0 to 25590
    TH_UM Fusing upper thermister MAIN center
    TH_LM Fusing lower thermister MAIN
    TH_US Fusing upper thermister SUB edge
    HL_UM Heater lamp upper MAIN
    HL_LM Heater lamp lower MAIN
    HL_US Heater lamp upper SUB
    0
    A:
    A:50
    B: 50
    C: 50
    D: 50NN_120_WUP_HL_UM&HL_US
    NN_120_WUP_HL_LM
    LL_120_WUP_HL_UM9ÒHL_US
    LL_120_WUP_HL_LM
    SIMULATION NO.43-24
    FUSER TEMP RESET
    50
    :1:*99:	
    OK
    TESTCLOSE 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 51
     
    44
     
    44-1
    Purpose: Setting
    Function (Purpose): Used to set whether the correction func-
    tions of the image forming (process) sec-
    tion are enabled or not.
    Section:—
    Item:—
    Operation/Procedure
    1) When the machine enters Simulation 44-01, the currently set
    button is highlighted.
    Set the item to be set to the normal display.
    (Two or more items can be selected.) When an item is
    selected, its button is highlighted. When the highlighted button
    is pressed again, it returns to the normal display.
    2) When [EXECUTE] button is pressed, the current set value is
    saved to EEPROM and RAM. After completion of setting,
    [EXECUTE] button returns to the normal display.
    *1: The transfer efficiency fluctuation is corrected with temperature 
    and humidity (absolute moisture). YES/NO setting. Transfer 
    high output voltage correction.
     
    44-2
    Purpose: Adjustment
    Function (Purpose): Used to perform the light quantity adjust-
    ment of the process control sensor and the
    registration sensor (two for resist are
    adjusted simultaneously) and the surface
    scan.
    Section: Process
    Item: Operation
    Operation/Procedure
    1) When [EXECUTE] button is pressed, it is highlighted and all
    the drum motors are driven to start the adjustments of the pro-
    cess control sensor and the registration sensor.
    * After completion of the adjustments of the process control
    sensor and the registration sensor, the drum motors are
    stopped and the set contents are displayed. The necessary
    data are saved to EEPROM.
    [EXECUTE] button returns to the normal display.
    * When [EXECUTE] button is pressed during adjustment of
    the process control sensor and the registration sensor, the
    monitor is terminated and the drum motor is stopped. [ECE-
    CUTE] button returns to the original state.
    Data saving is not performed, but the result at that time is
    displayed.
    * When an error occurs in the adjustment, ERROR is dis-
    played in the value display section at the right of the error
    item, and the drum motor is stopped. Data saving to
    EEPROM is not performed at all and the operation is termi-
    nated. [EXECUTE] button returns to the original state.
    * When there is a page over [↑], the display becomes active
    and shifts up to another page. When there is no page over
    [↑], the display grays out and the operation is disabled.
    * When there is a page under [↓], the display becomes active
    and shifts down to another page. When there is nor page
    under [↓], the display grays out and the operation is dis-
    abled.
    Display Content Set rangeDefault 
    value
    HV Normal operation high-
    density process control YES/
    NO settingNormal 
    (Inhibit: 1: NO)
    Highlighted 
    (Allow: 0: YES)Allow
    HT Normal operation half-tone 
    process control YES/NO 
    settingAllow
    TC Transfer output correction 
    YES/NO setting *1Allow
    MD VG Membrane decrease grid 
    voltage correction YES/NO 
    settingAllow
    MD LD Membrane decrease laser 
    power voltage correction 
    YES/NO settingInhibit
    MD EV Membrane decrease 
    environment grid voltage 
    correction YES/NO settingAllow
    MD DL Membrane decrease 
    discharge light quantity 
    correction YES/NO settingAllow
    MD DL EV Membrane decrease 
    environment discharge light 
    quantity correction YES/NO 
    settingInhibit
    TN_HUM Toner density humidity 
    correction YES/NO settingAllow
    TN_AREA Toner density area correction 
    YES/NO settingAllow
    TN_LIFE Toner density life correction 
    YES/NO settingAllow
    TN_COV Toner density print rate 
    correction YES/NO settingAllow
    TN_PROCO
    NToner density process control 
    correction YES/NO settingAllow
    TN_ENV Toner density environment 
    correction YES/NO settingAllow
    TN_DRIP Toner density correction, 
    unconditional supply YES/
    NO settingAllow
    TN_SPEND Toner compulsory 
    consumption mode YES/NO 
    settingAllow
    PHT 1Pixel half-tone process 
    control correction YES/NO 
    settingInhibit
    AR_AUTO Auto resist adjustment YES/
    NO settingNormal (Inhibit: 
    1: NO)
    Highlighted 
    (Allow: 0: YES)Allow
    AR_ERROR Error check YES/NO setting 
    during auto resist adjustmentAllow
    DM_PHASE Drum phase alignment YES/
    NO settingAllow
    SENSITIVITY Toner density correction 
    YES/NO settingInhibit
    PRT_HT Half tone process control 
    printer correction feedback 
    Enable/Disable settingAllow Display Content Set rangeDefault 
    value
    CLOSE0
    SIMULATION NO.44-01TEST
    MODE SETTING
    EXECUTE1/2
    HVHTTCMD VG
    MD LDMD EVMD DLMD DL EV
    TN_HUMTN_AREATN_LIFETN_COV
    TN_PROCONTN_ENVTN_DRIPTN_SPEND 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 52 
    1) Adjust so that the LED light emitting quantity of BK/CL is the
    target value ± 2.
    * Target value
    BK: Item B of SIM 44-04
    CL: Item A of SIM 44-13
    2) After completion of the adjustment, check the belt surface con-
    dition with the BK sensor.
    
    
     
    44-4
    Purpose:Setting
    Function (Purpose): Used to perform the correction operation of
    the image forming section and to set the
    process control sensor adjustment condi-
    tions.
    Section: Process
    Item: Operation
    Operation/Procedure
    NOTE: Unless a special change is required, set the set values to
    the default values.
    1) Select the set item with [↑] and [↓] buttons.
    The highlighted set value is switched and the value is dis-
    played in the setting area.
    * If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.
    If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.
    2) Enter the set value with 10-key.
    * Press [C] key to clear the entered values.
    When setting is completed, [OK] button returns to the normal
    display.
    Classification Item Display item Content Set range Default value Save
    PROCON A PCS_CL LED ADJ Color sensor light emitting quantity adjustment value 1 to 255 21 YES
    B PCS_K LED ADJ Black sensor light emitting quantity adjustment value 1 to 255 21 YES
    C PCS_CL DARK Color dark voltage 0 to 255 0 NO
    D PCS_K DARK Black dark voltage 0 to 255 0 NO
    E PCS_K GRND Belt surface when item B adjustment is completed. 0 to 255 0 NO
    F PCS_K BELT MAX Belt surface input max. value 0 to 255 0 NO
    G PCS_K BELT MIN Belt surface input min. value 0 to 255 0 NO
    H PCS_K BELT DIF Belt surface input difference (Item E – Item F) 0 to 255 0 NO
    REGIST I REG_F LED ADJ Registration sensor light emitting quantity adjustment value F 1 to 255 56 YES
    J REG_R LED ADJ Registration sensor light emitting quantity adjustment value R 1 to 255 56 YES
    K REG_F DARK Registration sensor dark voltage F 0 to 255 0 NO
    L REG_R DARK Registration sensor dark voltage R 0 to 255 0 NO
    M REG_F GRND Belt surface when completion of Item I adjustment 0 to 255 0 NO
    N REG_R GRND Belt surface when completion of Item J adjustment 0 to 256 0 NO
    O REG_F BELT MAX Belt surface input max. value (Front side) 0 to 255 0 NO
    P REG_F BELT MIN Belt surface input min. value (Front side) 0 to 255 0 NO
    Q REG_F BELT DIF Belt surface input difference (Item O – Item P) 0 to 255 0 NO
    R REG_R BELT MAX Belt surface input max. value (Rear side) 0 to 255 0 NO
    S REG_R BELT MIN Belt surface input min. value (Rear side) 0 to 255 0 NO
    T REG_R BELT DIF Belt surface input difference (Item R – Item S) 0 to 255 0 NO
    U REG_F PATCH (K) Patch light receiving potential F (K) 0 to 255 0 YES
    V REG_F PATCH (C) Patch light receiving potential F (C) 0 to 255 0 YES
    REGIST W REG_F PATCH (M) Patch light receiving potential F (M) 0 to 255 0 YES
    X REG_F PATCH (Y) Patch light receiving potential F (Y) 0 to 255 0 YES
    Y REG_R PATCH (K) Patch light receiving potential R (K) 0 to 255 0 YES
    Z REG_R PATCH (C) Patch light receiving potential R (C) 0 to 255 0 YES
    AA REG_R PATCH (M) Patch light receiving potential R (M) 0 to 255 0 YES
    AB REG_R PATCH (Y) Patch light receiving potential R (Y) 0 to 255 0 YES
    Error name Error content
    Black sensor 
    adjustment error→ PCS_K LED ADJ error, retry in 3 times, target 
    not reached
    Color sensor 
    adjustment error→ PCS_CL LED ADJ error, retry in 3 times, 
    target not reached
    Surface read error→ PCS_K GRND error, belt 1 lap, outside the 
    range of effective difference between upper and 
    lower values
    Registration sensor F 
    adjustment error→ REG_F LED ADJ error, retry in 3 times, target 
    not reached
    Registration sensor R 
    adjustment error→ REG_R LED ADJ error, retry in 3 times, target 
    not reached
    Registration surface F 
    read error→ REG_F GRND error, belt 1 lap, outside the 
    range of effective difference between upper and 
    lower values
    Registration surface R 
    read error→ REG_R GRND error, belt 1 lap, outside the 
    range of effective difference between upper and 
    lower values
    0
    SIMULATION NO.44-02TEST
    PROCON GAIN ADJUSTMENT
    EXECUTE
    PCS_CL LED ADJ21:
    PCS_K GRND0:
    PCS_K LED ADJ
    21:
    PCS_K BELT MAX0:
    PCS_CL DARK
    0:
    PCS_K BELT MIN0:
    PCS_K DARK
    0:
    PCS_K BELT DIF0:
    1/4
    CLOSE 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 53 3) When [OK] button is pressed, the current set value is saved to
    EEPROM and RAM.
    * When [↑], [↓], [COLOR], or [BLACK] key is pressed, the cur-
    rent set value is saved to EEPROM and RAM.
    
     
    44-6
    Purpose: Operation test/Check
    Function (Purpose): Used to forcibly execute the correction in
    the image process section (high-density
    process correction) (process correction).
    Section:Process
    Item: Operation
    Operation/Procedure
    1) When the machine enters SIM 44-06, the screen shown on the
    right is displayed.
    2) When [EXCECUTE] button is pressed, it is highlighted and all
    the drum motors are driven to rotate. The high-density process
    control is started.
    3) While the high-density process control is executed, NOW
    EXECUTING... is displayed.
    4) After completion of the high-density process control, the drum
    motors are stopped and [EXECUTE] button returns to the nor-
    mal display.When the operation is completed normally, COMPLETE is
    displayed and the execution result is saved to EEPROM and
    RAM.
    In case of an error, ERROR is displayed and the details of
    the error are displayed below.
    * When the high-density process control is interrupted by an
    external factor (pressing [EXECUTE] button), the forcible
    interruption screen is displayed and the drum motors are
    stopped. [EXECUTE] button returns to the normal display.
    * The result of the high-density process control is displayed
    with the following simulations:
    SIM.44-09 (Process control result display (High density cor-
    rection))
    SIM.44-12 (Process control result display (Half tone correc-
    tion))
    
    
    * (*) Same as the error in SIM 44-02.
     
    44-9
    Purpose: Adjustment/Setup/Operation data output/
    Check (Display/Print)
    Function (Purpose): Used to check the data related to the result
    of the image forming section correction
    (high density process correction). (Cor-
    rected main charger grid voltage in each
    print mode, developing bias voltage, etc.)
    (This simulation is used to check whether
    the correction is normally executed or not.)
    Section: Process
    Item: Data (Machine condition)
    Operation/Procedure
    1) Change the page with [↑] [↓] buttons.
    * If there is a page over [↑], an active display is shown and the
    page moves up. If there is no page upward, the display
    grays out and the operation is invalid.
    If there is a page under [↓], an active display is shown and
    the page moves down. If there is no page downward, the
    display grays out and the operation becomes invalid.
    2) Select a mode with the following buttons:
    [CPY/PRN] button: Display of each process control mode in
    the copier/printer.
    Item Display contentSet 
    rangeDefault 
    value
    A PCS_CL TARGET Color sensor target set 
    value1 to 255 108
    B PCS_K TARGET Black sensor target set 
    value1 to 255 155
    C LED_CL OUTPUT Color sensor light 
    emitting quantity set 
    value1 to 255 21
    D LED_K OUTPUT Black sensor light 
    emitting quantity set 
    value1 to 255 21
    E PCS ADJSTMENT 
    LIMITSensor adjustment 
    target limit value1 to 255 2
    F BELT GROUND 
    DIFBelt 1 lap, effective 
    difference between 
    upper and lower values1 to 255 255
    GBIAS_CL 
    STANDARD DIFBias (for color) 
    reference calculating 
    difference0 to 255 0
    H BIAS_BK 
    STANDARD DIFBias (for black) 
    reference calculating 
    difference0 to 255 0
    I BIAS PATCH 
    INTERVALPatch bias output 
    interval1 to 255 60
    JY_PAT TARGET 
    IDPatch density standard 
    value (YELLOW)1 to 255 123
    K M _ PAT  TAR G E T  
    IDPatch density standard 
    value (MAGENTA)1 to 255 140
    LC_PAT TARGET 
    IDPatch density standard 
    value (CYAN)1 to 255 132
    MK_PAT TARGET 
    IDPatch density standard 
    value (BLACK)1 to 255 5
    N HV BK_GROUND 
    LIMITPatch position surface 
    light receiving effective 
    range1 to 255 29
    0
    A:A:108
    B : 155
    C:21
    D: 219çPCS_C TARGET
    9çPCS_K TARGET
    9çLED_C OUTPUT
    9çLED_K OUTPUT
    SIMULATION NO.44-04
    PROCON INITIAL DENSITY SETUP
    108
    :1:*255:	
    OK
    TESTCLOSE
    Result display Content description
    COMPLETE Normal completion
    ERROR Abnormal completion
    INTERRUPTION Forcible interruption
    Detailed error display Content description
    CL_SEN_ADJ_ERR Color sensor adjustment error (*)
    BK_ SEN _ADJ_ERR Black sensor adjustment error (*)
    K_HV_ERR K high density process control error
    C_ HV_ERR C high density process control error
    M_ HV_ERR M high density process control error
    Y_ HV _ERR Y high density process control error
    TIMEOUT_ERR Timeout
    SIMULATIONNO.4406TESTPROCON COMPULSORY EXECUTION
    EXECUTE
    0CLOSE
    PRESS[EXECUTE] TO START 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 54 [OTHER] button: Display of environment area, membrane
    decrease correction steps and process control execution
    counter, and model type.
    * When [CLOSE] button is pressed, the display shifts to the copy
    basic screen of simulation.
    * Copying can be performed also by pressing [COLOR]/[BLACK]
    key.
    
    Mode Page number Display item (*: correction value) Content description Display rangeDefault 
    value
    CPY/PRN 1/2 P (PROCON) Left BLACK : GB ***/*** DV ***/*** High density process control GB/DV 
    data (KCMY)GB: 230 to 850
    DV: 0 to 700GB: 630
    DV: 430
    CYAN : GB ***/*** DV ***/***
    MAGENTA : GB ***/*** DV ***/***
    YELLOW : GB ***/*** DV ***/***
    N (M) 
    (NORMAL 
    (MIDDLE))Right BLACK : GB ***/*** DV ***/*** High density normal (middle speed 
    display) GB/DV data (KCMY)GB: 230 to 850
    DV: 0 to 700GB: 630
    DV: 430
    CYAN : GB ***/*** DV ***/***
    MAGENTA : GB ***/*** DV ***/***
    YELLOW : GB ***/*** DV ***/***
    2/2 N (L) (NORMAL 
    (LOW))BLACK : GB ***/*** DV ***/*** High density normal (low speed 
    display) GB/DV data (KCMY)GB: 230 to 850
    DV: 0 to 700GB: 600
    DV: 400
    CYAN : GB ***/*** DV ***/***
    MAGENTA : GB ***/*** DV ***/***
    YELLOW : GB ***/*** DV ***/***
    OTHER 1/10 TN/TC Left TN HUD AREA Toner control display humidity area 1 to 14 9
    TN HUD DATA Toner control display humidity AD 
    value0 to 1023 0
    TC TMP AREA Transfer display temperature area 1 to 9 4
    TC TMP DATA Transfer display temperature AD value 0 to 1023 0
    Right TC HUD AREA Transfer display humidity area 1 to 9 4
    TC HUD DATA Transfer display humidity AD value 0 to 1023 0
    MD HUD AREA Membrane decrease display humidity 
    area1 to 14 9
    MD HUD DATA membrane decrease display humidity 
    AD value0 to 1023 0
    2/10 DRUM Left MD K STEP Drum membrane decrease correction 
    step display (KCMY)0 to 4 0
    MD C STEP
    MD M STEP
    MD Y STEP
    MD K DRUM COUNTER Membrane decrease drum traveling 
    distance area0 to 20 0
    MD C DRUM COUNTER
    MD M DRUM COUNTER
    MD Y DRUM COUNTER
    3/10 VG MD K REVISE(VG) : L *** M *** H*** Drum membrane decrease grid voltage 
    correction display (KCMY)0 to 255 0
    MD C REVISE(VG) : L *** M *** 
    MD M REVISE(VG) : L *** M ***
    MD Y REVISE(VG) : L *** M ***
    4/10 LD MD K REVISE(LD) : L *** M *** H*** Drum membrane decrease laser power 
    voltage correction (KCMY)0 to 255 0
    MD C REVISE(LD) : L *** M ***
    MD M REVISE(LD) : L *** M ***
    MD Y REVISE(LD) : L *** M ***
    5/10 HV MD K REVISE(HV) : L *** M *** H*** High density membrane decrease 
    environment GB correction display 
    (KCMY)0 to 255 0
    MD C REVISE(HV) : L *** M ***
    MD M REVISE(HV) : L *** M ***
    MD Y REVISE(HV) : L *** M ***
    6/10 CP MD K REVISE(CP) : L *** M *** H*** Drum membrane decrease 
    environment grid voltage correction 
    display (KCMY)0 to 255 0
    MD C REVISE(CP) : L *** M ***
    MD M REVISE(CP) : L *** M ***
    MD Y REVISE(CP) : L *** M ***
    7/10 DL MD K  REVISE COL (DL): L ***  M *** Drum membrane decrease discharge 
    light quantity correction (%) 0 to 100 50
    MD C  REVISE COL (DL): L ***  M ***
    MD M  REVISE COL (DL): L ***  M ***
    MD Y  REVISE COL (DL): L ***  M ***
    8/10 DL EV MD K  REVISE COL (DL  EV): L ***  M*** Drum membrane decrease 
    environment discharge light quantity 
    correction (%)–100 to 100 0
    MD C  REVISE COL (DL  EV): L ***  M*** 
    MD M  REVISE COL (DL  EV): L ***  M***
    MD Y  REVISE COL (DL  EV): L ***  M*** 
    						