Page 21
19 R-1500 R-1501 R-1505 R-1506 TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. Refer to procedure of " HOOD EXHAUST LOUVER REMOVAL ", " REMOVAL OF OVEN FROM WALL " and " OUTER CASE REMOVAL ". 2. Open the door and block it open. 3. To discharge high voltage capacitor, wait for 60 seconds. 4. Remove the hood intake duct R. 5. Disconnect the leads to the primary of the power transformer. 6. Ensure that these leads remain...
Page 22
20 R-1500 R-1501 R-1505 R-1506 TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST 1. Foil pattern check and repairs. 1) Disconnect the power supply cord. 2) Open the door and block it open. 3) To discharge high voltage capacitor, wait for 60 seconds. 4) Remove the control unit, referring to the procedure of " CONTROL PANEL ASSEMBLY, CONTROL UNIT AND KEY UNIT REMOVAL ". 5) Follow the troubleshooting guide given below for repair. STEPS OCCURRENCE CAUSE OR CORRECTION 1 Only pattern at "a" is...
Page 23
21 R-1500 R-1501 R-1505 R-1506 DESCRIPTION OF LSI LSI The I/O signal of the LSI is detailed in the following table. Pin No. Signal I/O Description 1-2 VL2-VL1 INPower source voltage input terminal. Standard voltage for LCD. 3-6 AN7-AN4 IN Terminal to change cooking input according to the Model. By using the A/D converter contained in the LSI, DC voltage in accordance with the Model in operation is applied to set up its cooking constant. 7 AN3 OUT Back light circuit (Light emitting diodes) driving...
Page 24
22 R-1500 R-1501 R-1505 R-1506 15 P53 OUT Terminal not used. 16 P52 OUT Oven lamp, fan motor and turntable motor driving signal To turn on and off shut off relay (RY1). The square waveform voltage is delivered to the RY1 driving circuit and RY2 control circuit. 17-18 P51-P50 OUT Terminal not used. 19 P47 OUT Magnetron high-voltage circuit driving signal. To turn on and off the cook relay (RY2). The signals holds "L" level during microwave cook- ing and "H" level while not cooking. In...
Page 25
23 R-1500 R-1501 R-1505 R-1506 37 P23 OUTKey strobe signal. Signal applied to touch-key section. A pulse signal is input to P43-P46 terminal while one of G4 line keys on key matrix is touched. 38 P22 OUT Key strobe signal. Signal applied to touch-key section. A pulse signal is input to P43-P46 terminal while one of G3 line keys on key matrix is touched. 39 P21 OUT Key strobe signal. Signal applied to touch-key section. A pulse signal is input to P43-P46 terminal while one of G2 line keys on key matrix is...
Page 26
24 R-1500 R-1501 R-1505 R-1506 1. Precautions for Handling Electronic Components This unit uses CMOS LSI in the integral part of the circuits. When handling these parts, the following precautions should be strictly followed. CMOS LSI have extremely high impedance at its input and output terminals. For this reason, it is easily influenced by the surrounding high voltage power source, static electricity charge in clothes, etc. and sometimes it is not fully protected by the built-in protection circuit. In...
Page 27
25 R-1500 R-1501 R-1505 R-1506 Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts may result in severe, possibly fatal, electric shock. (Example) High Voltage Capacitor, Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness etc.. WARNING:Avoid possible exposure to microwave energy. Please follow the instructions below before operating the oven. WARNING AGAINST HIGH VOLTAGE: COMPONENT REPLACEMENT AND ADJUSTMENT...
Page 28
26 R-1500 R-1501 R-1505 R-1506 REMOVAL OF OVEN FROM WALL (Two persons recommended to remove the oven) 1. Disconnect the power supply cord, and uncoil the power supply cord. 2. To discharge the high voltage capacitor, wait for 60 seconds. 3. Remove the turntable tray and support from the oven cavity. 4. If the exhaust damper assembly is installed, remove the one (1) screw holding the exhaust damper assembly to the rear stay, and remove the exhaust damper assembly by sliding it backward. 5. Remove the...
Page 29
27 R-1500 R-1501 R-1505 R-1506 4. Disconnect the 6-pin connector of the hood fan motor from the main wire harness located at the right edge of the oven cavity top plate and release the snap band from the hood duct.5. Remove the hood fan motor from the oven cavity top plate by lifting it up. 6. Now, the hood fan motor is free. 1. Disconnect the power supply cord , remove the oven from wall and remove outer case (Refer to procedure of "Removal of Oven from Wall" and "Outer case Removal".)...
Page 30
28 R-1500 R-1501 R-1505 R-1506 1. Disconnect the power supply cord, remove the oven from wall and remove outer case (Refer to procedure of "Removal of Oven from Wall" and "Outer case Removal".) 2. Open the door and block it open. 3. To discharge the high voltage capacitor, wait for 60 seconds. 4. Remove the three (3) screws holding the hood intake duct R to the oven cavity top plate, the oven cavity front flange and the fan duct. And remove the hood intake duct R. 5. Remove the one (1)...