    							AE55H OWNER’S MANUAL
    11 GENERAL GUIDE TO SCANNING
    BIRDIE FREQUENCIES
    Every scanner has birdie frequencies. Birdies are signals created inside the scanner’s receiver. These
    operating frequencies might interfere with broadcasts on the same frequencies. If you program one of
    these frequencies, you hear only noise on that frequency. If the interference is not severe, you might be
    able to turn SQUELCH clockwise to cut out the birdie.
    To find the birdies in your scanner, being by disconnecting the antenna and moving it away from the
    scanner. Make sure that no other nearby radio or TV sets are turned on near the scanner. Use the
    search function and scan every frequency range from its lowest frequency to the highest. Occasionally,
    the searching will stop as if it had found a signal, often without any sound. That is a birdie. Make a list of
    all the birdies in your scanner for future reference.
    SPECIFIED INTERVALS
    Frequencies in different bands are accessible only at specific intervals. For example:
    Frequency RangesSpecified Interval
    26-54, 68-88, 137-144 and 146-174 MHz5.0 kHz steps
    144-146 and 380-512 MHz12.5 kHz steps
    TROUBLESHOOTING
    If your scanner is not working as it should, these suggestions might help you eliminate the problem. If
    the scanner still does not operate properly, take it to your local store for assistance.
    ProblemPossible CausesRemedies
    -------------------------------------------------------------------------------------------------------------------------
    The scannerThe AC or DC adapter is notBe sure the adapter is plugged into
    does not workproperly connected.a working AC outlet or cigarette-
    at all.lighter socket, and is fully
    inserted into the scanner’s
    PWR jack.
    -------------------------------------------------------------------------------------------------
    The internal batteries/batteryCharge the rechargeable batteries
    pack needs to be recharged, oror battery pack, or replace non-
    the non-rechargeable batteriesrechargeable batteries with fresh
    are dead.batteries.
    -------------------------------------------------------------------------------------------------------------------------
    Poor or noImproperly connected antenna.Be sure the antenna is properly
    reception.connected.
    -------------------------------------------------------------------------------------------------
    Programmed frequencies are theAvoid programming frequencies
    same as birdie frequencies.listed under “Birdie Frequencies”
    on Page ??.
    -------------------------------------------------------------------------------------------------------------------------
    Scanner is on,SQUELCH is not correctly Adjust SQUELCH clockwise (see
    but does notadjusted.“Turning On the Scanner/Setting
    scanVolume and Squelch”.
    -------------------------------------------------------------------------------------------------------------------------
    In the scanProgrammed frequencies are theAvoid programming frequencies
    mode, thesame as birdie frequencies.listed under “Birdie Frequencies”
    scanner locksor only listen to them manually
    on frequencies
    that have an
    unclear trans-
    mission. 
    						
    							AE55H OWNER’S MANUAL
    12 RESETITNG/INITIALIZING THE SCANNER
    If the scanner’s display locks up or does not work properly after you connect a power source, you might
    need to reset or initialize it.
    Important: If you have problems, first try to reset the scanner. If that does not work, you can initialize the
    scanner, however, initializing clears all frequencies you stored in the scanner’s memory and initialilzes
    the scanner to its default settings.
    Resetting the Scanner
    1. Turn off the scanner, then turn it on again.
    2. Insert a pointed object, such as a straightened paper clip, into the reset hole on the side of the
    scanner. Then gently press and release the reset button inside the opening. The display goes blank,
    then information reappears.
    Initializing the Scanner
    Important: This procedure clears all frequencies you stored in the scanner’s memory and initializes the
    scanner to its default settings. Initialize the scanner only when you are sure the scanner is not working
    properly.
    1. Turn off the scanner, then turn it on again.
    2. While holding down CLEAR, insert a pointed object, such as a straightened paper clip, into the reset
    hole on the side of the scanner. Then gently press and release the reset button inside the opening. The
    display goes blank, then information reappears.
    Note: You must release the reset button before you release CLEAR. Otherwise, the memory might not
    clear.
    3. When the display reappears, release CLEAR.
    CARE AND MAINTENANCE
    The following suggestions will help you care for your scanner so you can enjoy it for years.
    Keep the scanner dry. If it gets wet, wipe it dry immediately.
    Use only fresh batteries of the required size and type. Always remove old and weak batteries. They can
    leak chemicals that destroy electronic circuits.
    Handle the scanner gently and carefully. Dropping it can damage circuit boards and cases and can
    cause the scanner to work improperly.
    Use and store the scanner only in normal temperature environments. Temperature extremes can
    shorten the life of electronic devices, damage batteries, and distort or melt plastic parts.
    Keep the scanner away from dust and dirt, which can cause premature wear of parts.
    Wipe the scanner with a damp cloth occasionally to keep it looking new. Do not use harsh chemicals,
    cleaning solvents, or strong detergents to clean the scanner. 
    						
    							AE55H OWNER’S MANUAL
    13 SPECIFICATIONS
    Frequency Coverage
    26-54 MHz
    68-88 MHz
    137-174 MHz
    380-512 MHz
    Channels of Operation50 Channels and 1 Monitor Memory
    Sensitivity (20dB S/N):
    26-54 MHz0.7 uV
    68-88 MHz0.7 uV
    137-174 MHz0.7 uV
    380-512 MHz0.7 uV
    Selectivity:
    +/-10kHz-6 dB
    +/-18kHz-50 dB
    Spurious Rejection:
    26-54 MHz50 dB at 41 MHz
    68-88 MHz50 dB at 78 MHz
    137-174 MHz50 dB at 154 MHz
    Scanning RateUp to 25 channels/second
    Search RateUp to 50 steps/second
    Delay Time2 seconds
    Intermediate Frequencies (IF):
    1st
    10.7 MHz
    2nd
    455 kHz
    IF Rejection: 10.7 MHz70 dB at 154 MHz
    Squelch Sensitivity:
    ThresholdLess than 0.5 uV
    Tight(S+N)/N 25 dB
    Antenna Impedance50 ohms
    Audio Output Power200 mW Nominal (10% THD)
    Built-in Speaker36 mm, 8-ohm Dynamic Type
    Power Requirements9 V DC, 6 AA batteries
    AC adapter/DC adapter (9V, 200 mA)
    Current Drain (Squelched)50 mA
    Dimensions171 (H) x 59 (W) x 40 (D) mm
    Weight240 g without antenna and batteries
    Supplied AccessoryAntenna