    							8 - 3
    Codabar Concatenation
    Codabar supports symbol concatenation.  When you enable concatenation, the scanner looks for a Codabar symbol having 
    a “D” start character, adjacent to a symbol having a “D” stop character.  In this case the two messages are concatenated 
    into one with the “D” characters omitted. 
    Select Require to prevent the scanner from decoding a single “D” Codabar symbol without its companion.  This selection 
    has no effect on Codabar symbols without Stop/Start D characters.
    Validate Modulo 16 
    and Transmit
    Validate Modulo 7 CD, but Don’t 
    Transmit
    Validate Modulo 7 CD and 
    Transmit
    Validate CLSI, but Don’t 
    Transmit
    Validate CLSI and Transmit
    A1234DD5 6 7 8 A
    On
    * Off
    Require 
    						
    							8 - 4
    Concatenation Timeout
    When searching for bar codes during concatenation, you may wish to set a delay used to find the next bar code.  Set 
    the length (in milliseconds) for this delay by scanning the following bar code, then setting the timeout (from 1-65535 
    milliseconds) by scanning digits from the Programming Chart, then scanning Save.  Default = 750.
    Codabar Redundancy
    If you are encountering errors when reading Codabar bar codes, you may want to adjust the redundancy count.  Redun-
    dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  
    Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redundancy, scan 
    the following Codabar Redundancy bar code, then scan a redundancy count between 0 and 10 on the Programming Chart 
    inside the back cover of this manual.  Then scan the Save bar code.  Default = 0.
    Codabar Message Length
    Scan the following bar codes to change the message length.  Refer to Message Length Description (page 8-1) for addi-
    tional information.  Minimum and Maximum lengths = 1-80.  Minimum Default = 3, Maximum Default = 80.
    Concatenation Timeout
    Codabar Redundancy
    Minimum Message Length
    Maximum Message Length 
    						
    							8 - 5
    Code 39
    < Default All Code 39 Settings >
    Code 39 On/Off
    Code 39 Start / Stop Characters
    Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/
    Stop characters.  Default =  Don’t Transmit.
    Code 39 Check Character
    No Check Character indicates that the scanner reads and transmits bar code data with or without a check character.
    When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 bar codes printed with a check 
    character, but will not transmit the check character with the scanned data.  
    When Check Character is set to Validate and Transmit, the scanner only reads Code 39 bar codes printed with a check 
    character, and will transmit this character at the end of the scanned data.  Default = No Check Character.
    *  On
    Off
    Transmit
    *  Don’t Transmit
    *  No Check Character
    Validate, but Don’t Transmit
    Validate and Transmit 
    						
    							8 - 6
    Code 39 Redundancy
    If you are encountering errors when reading Code 39 bar codes, you may want to adjust the redundancy count.  Redun-
    dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  
    Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redundancy, scan 
    the Code 39 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart 
    inside the back cover of this manual.  Then scan the Save bar code.  Default = 0.
    Code 39 Message Length
    Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
    information.  Minimum and Maximum lengths = 1-80.  Minimum Default = 3, Maximum Default = 80.
    Code 32 Pharmaceutical (PARAF)
    Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies.  This symbology is also known as 
    PA R A F.
    Code 39 Redundancy
    Minimum Message Length
    Maximum Message Length
    On
    *  Off 
    						
    							8 - 7
    Full ASCII
    If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single 
    character.  For example:  $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #.  
    Default = Off.
    Character pairs /M and /N decode as a minus sign and period respectively.
    Character pairs /P through /Y decode as 0 through 9.
    NUL %UDLE $PSP SPACE00@%VPP‘%Wp+P
    SOH $A
    DC1 $Q!/A11AAQQa+Aq+Q
    STX $B
    DC2 $R“/B22BBRRb+Br+R
    ETX $C
    DC3 $S#/C33CCSSc+Cs+S
    EOT $D
    DC4 $T$/D44DDTTd+Dt+T
    ENQ $E
    NAK $U%/E55EEUUe+Eu+U
    ACK $F
    SYN $V&/F66FFVVf+Fv+V
    BEL $G
    ETB $W‘/G77GGWWg+Gw+W
    BS $H
    CAN $X(/H88HHXXh+Hx+X
    HT $I
    EM $Y)/I99IIYYi+Iy+Y
    LF $J
    SUB $Z*/J:/ZJJZZj+Jz+Z
    VT $K
    ESC %A+/K;%FKK[%Kk+K{%P
    FF $L
    FS %B,/L%INN^%Nn+N~%S
    SI $O
    US %E//O?%JOO_%Oo+ODEL %T
    Full ASCII On
    *  Full ASCII Off 
    						
    							8 - 8
    Interleaved 2 of 5
    < Default All Interleaved 2 of 5 Settings >
    Interleaved 2 of 5 On/Off
    NULL Characters
    Interleaved 2 of 5 requires an even number of characters.  When an odd number of characters is present, it is due to NULL 
    characters embedded in the bar code.  Scan the On bar code below to decode this type of Interleaved 2 of 5 bar code.  
    Default = Off.
    Check Digit
    No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit.
    When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes printed with a 
    check digit, but will not transmit the check digit with the scanned data.  
    When Check Digit is set to Validate and Transmit, the scanner only reads Interleaved 2 of 5 bar codes printed with a 
    check digit, and will transmit this digit at the end of the scanned data.  Default = No Check Digit.
    *  On
    Off
    *  Off
    On
    * No Check Digit
    Validate, but Don’t Transmit 
    						
    							8 - 9
    Interleaved 2 of 5 Redundancy
    If you are encountering errors when reading Interleaved 2 of 5 bar codes, you may want to adjust the redundancy count.  
    Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of 
    errors.  Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redundancy, 
    scan the Interleaved 2 of 5 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the 
    Programming Chart inside the back cover of this manual.  Then scan the Save bar code.  Default = 0.
    Interleaved 2 of 5 Message Length
    Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
    information.  Minimum and Maximum lengths = 1-80.  Minimum Default = 6, Maximum Default = 80.
    NEC 2 of 5
    < Default All NEC 2 of 5 Settings >
    NEC 2 of 5 On/Off
    Check Digit
    No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit.
    Validate and Transmit
    Interleaved 2 of 5 Redundancy
    Minimum Message Length
    Maximum Message Length
    On
    *  Off 
    						
    							8 - 10
    When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 bar codes printed with a check 
    digit, but will not transmit the check digit with the scanned data.  
    When Check Digit is set to Validate and Transmit, the scanner only reads NEC 2 of 5 bar codes printed with a check digit, 
    and will transmit this digit at the end of the scanned data.  Default = No Check Digit.
    NEC 2 of 5 Redundancy
    If you are encountering errors when reading NEC 2 of 5 bar codes, you may want to adjust the redundancy count.  Redun-
    dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  
    Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redundancy, scan 
    the NEC 2 of 5 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart 
    inside the back cover of this manual.  Then scan the Save bar code.  Default = 0.
    NEC 2 of 5 Message Length
    Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
    information.  Minimum and Maximum lengths = 1-80.  Minimum Default = 3, Maximum Default = 80.
    * No Check Digit
    Validate, but Don’t Transmit
    Validate and Transmit
    NEC 2 of 5 Redundancy
    Minimum Message Length
    Maximum Message Length 
    						
    							8 - 11
    Code 93
    < Default All Code 93 Settings >
    Code 93 On/Off
    Code 93 Redundancy
    If you are encountering errors when reading Code 93 bar codes, you may want to adjust the redundancy count.  Redun-
    dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  
    Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redundancy, scan 
    the Code 93 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart 
    inside the back cover of this manual.  Then scan the Save bar code.  Default = 0.
    Code 93 Message Length
    Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
    information.  Minimum and Maximum lengths = 1-80.  Minimum Default = 3, Maximum Default = 80.
    *  On
    Off
    Code 93 Redundancy
    Minimum Message Length
    Maximum Message Length 
    						
    							8 - 12
    Straight 2 of 5 Industrial (three-bar start/stop)
    
    Straight 2 of 5 Industrial On/Off
    Straight 2 of 5 Industrial Redundancy
    If you are encountering errors when reading Straight 2 of 5 Industrial bar codes, you may want to adjust the redundancy 
    count.  Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number 
    of errors.  Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redun-
    dancy, scan the Straight 2 of 5 Industrial Redundancy bar code below, then scan a redundancy count between 0 and 10 
    on the Programming Chart inside the back cover of this manual.  Then scan the Save bar code.  Default = 0.
    Straight 2 of 5 Industrial Message Length
    Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
    information.  Minimum and Maximum lengths = 1-80.  Minimum Default = 3, Maximum Default = 80.
    On
    *  Off
    Straight 2 of 5 Industrial 
    Redundancy
    Minimum Message Length
    Maximum Message Length 
    						