    USER FUNCTIONS 
    Scheduling User Interface  
     
    To access the Scheduling User Interface enter:                         + FUNCTION  +  [64] 
      Master user code or  
     Installer Code 
     The following entries will be sequentially prompted to the user. Note that all inputs are checked for 
    validity upon entry and all invalid entries are rejected. Hitting a [*] will allow the entries to be 
    accepted and advance to the next field. Hitting a [#] will reject the entry and back up one field. Hitting 
    the [#] in the “Schedule Number” screen will exit the schedule programming. 
     
    NOTES: 1.  During the schedule programming, if three minutes passes and no key was entered, the 
    programming will be terminated and no values will be saved. Furthermore, if a zone is troubled 
    while in schedule programming, the system will abort the programming mode and show the 
    troubled zone, and any uncompleted program event will not be saved.  
     2.  It is not possible to enter the schedule programming mode from a wireless keypad. 
      3.  Pressing any key on a wireless (RF) keypad terminates Scheduling setup. 
      4.  It is not possible to enter the schedule programming mode when either FC or CA is displayed on the 
    display. 
     
    Because the keypad display does not show prompt titles, you must refer to these instructions while 
    programming the system. The prompts are indicated by a number/letter combination. 
    The prompts for option #64 are as follows: 
     
        n 
      Schedule number-------------  for selecting a schedule number (1-8) 
     
       i d 
      Event identifier---------------  for selecting a schedule action (0-5) 
     
      : A b 
      Begin time (hrs, am/pm)----  for selecting a schedule begin time (hour, am/pm) 
     entry (00-12)  
     b :    
      Begin time (min)-------------  for selecting a schedule begin time (minute) 
     entry (00-59)  
       b d 
      Begin day---------------------  for selecting a schedule begin day (01-17)   
      
      : A E 
      End time (hrs, am/pm)------  for selecting a schedule end time (hour, am/pm) 
     entry (00-12)   
     E :     
      End time (min)---------------  for selecting a schedule end time (minute) 
     entry (00-59)  
       E d 
      End day------------------------  for selecting a schedule end day (01-17) 
     
       d n 
      Device number---------------  for selecting a X-10 device number (1-8) 
      
    						
    							– 32 – 
    USER FUNCTIONS 
    Scheduling User Interface 
     NOTE:  The keypad beeps twice for invalid data entries (e.g.: an hour greater than 12), and the entry will not be 
    accepted. The keypad beeps once for valid entries and four times when a schedule event is programmed 
    successfully. 
    [x] = the value that was last stored in the memory.   
     x n 
    Schedule number 
    [x] = schedule number 1 to 8 
    [*] = continue 
    [#] = exit schedule programming 
    mode 
     
     
     
     
     
     
    Enter the 1-digit schedule number to be programmed, then 
    press [*] to accept and advance to the next programming field: 
    Event Identifier. 
    •  Press the [#] key in this entry will exit the schedule 
    programming mode. The keypad will beep four times and 
    exit. 
    • Schedule number 7 and 8 are always random events that 
    are meant to work only with X-10 devices.  
    NOTE: This feature should be implemented when the user is 
    trying to give the impression that a premises is “lived in”. 
    The events will occur at random times (0-59 minutes) 
    within the defined hour. 
     
      x id 
    Event Identifier 
    [x] = event identifier 0 to 5 
    [*] = continue 
    [#] = return to previous prompt 
     
    0 = Empty - no event scheduled (or schedule temporarily 
    disabled. Keypad will beep four times and return to 
    Schedule Number with the schedule number advanced.  
    1 = X-10 Device - the user is required to enter data up to and 
    include the Device Number screen. Selection #1 is a time 
    driven event that requires a begin and end time. 
    2 = Latch Key Report - the user is required to enter data up 
    to and include the End Day screen. Selection #2 is a window 
    driven event that requires a begin/end time. 
    3 = Automatic Stay Arming - the user is required to enter 
    data up to and include the Begin Day screen.  Selection #3 is 
    a time driven event that requires a begin time to send a 
    report. 
    4 = Reminder Announcements - the user is required to enter 
    data up to and include the Begin Day screen. This is a 
    reminder announcement. 
    5 = Alarm Clock - the user is required to enter the field 
    values up to and include the Begin Day screen. This is a an 
    alarm clock.
     NOTES:   (1) See figure 1 for an explanation of each entry of the 
    event identifier. 
      (2)  If  “Follow me” reminder telephone number is 
    programmed, the reminder announcement is also 
    delivered to that number.
      
    xx :  Ab 
    Begin Time (hour) 
    [xx] = begin hour 00 to 12 
    [*] = continue 
    [#] = return to previous prompt 
    Begin Time (am/pm) 
    [0] = begin time, am (A) 
    [1] = begin time, pm (P) 
    [*] = continue 
    [#] = return to previous prompt
     
    •  The begin hour is a two-digit entry. To enter the hour 3, 
    press “0” followed by “3”. 
    •  The begin hour “00” indicates this schedule does not have 
    a begin time. 
    •  Press “0” to select AM or  “1” to select PM. NOTE: When programming schedule number 7 and 8, do not 
    program turn on/off to occur within the same 1-hour 
    period. This will prevent this random feature from 
    causing a reversal of the on/off times.  
    						
    							– 33 – 
    USER FUNCTIONS 
    Scheduling User Interface 
      
     b :   xx 
    Begin Time (minute) 
    [xx] = begin minute 0 to 59 
    [*] = continue 
    [#] = return to previous prompt 
      
     
    xx : bd 
    Begin Day 
    [xx] = begin day 01 to 17 
    [*] = continue 
    [#] = return to previous prompt 
     
     •  If  the value programmed in the Event Identifier is “3”, 
    “4”, or “5”, and the current entry is completed, the 
    system will save all field data up to this field. The 
    system will beep four times and go back to the first field 
    (Schedule Number) with the schedule number 
    advanced. 
    •  If  the value programmed in the Event Identifier is “1” 
    or “2”, and the current entry is completed, the system 
    will advanced to the next programming field - End Time 
    (hour). 
     
    NOTE:  See figure 2 for the definition of begin day entries.   
     xx : AE 
    End Time (hour) [xx] = end hour 00 to 12 
    [*] = continue 
    [#] = return to previous prompt 
     
    End Time (am/pm) [0] = end time, am (A) 
    [1] = end time, pm (P) 
    [*] = continue 
    [#] = return to previous prompt 
     
    •  The end hour is a two-digit entry. To enter the hour 3, 
    press “0” followed by “3”. 
    •  The end hour “00” indicates this schedule does not have 
    a end time. 
    •  Press “0” to select AM or  “1” to select  PM. 
     
     
      E :   xx 
    End Time (minute) [xx] = end minute 0 to 59 
    [*] = continue 
    [#] = return to previous prompt 
     
     
     
     xx : Ed 
    End Day [xx] = end day 01 to 17 
    [*] = continue 
    [#] = return to previous prompt
     
    NOTE:  See figure 2 for the definition of end day entries. 
     
    •  If  the event identifier is set to “2” upon completion of 
    this field, the current schedule data will be saved and 
    the system will go back to the next schedule number. 
      
     x   : dn 
    Device Number [xx] = device number 1 to 8 
    [*] = continue 
    [#] = return to previous prompt 
     
    [*]  will accept and save the entire schedule event. The 
    system will beep four times and go back to the beginning 
    of the  programming field (Schedule Number) with the 
    schedule number advanced. If the current schedule 
    number is 8, the system will wrap around and set the 
    schedule number to 1. 
     
    NOTE: For X-10 devices.  
      
    						
    							– 34 – 
     
     
    USER FUNCTIONS 
    Scheduling User Interface  
     
    Event Identifier Entries 
     
    Entry Event Comment 
    0 Empty  No event scheduled (or schedule is temporarily disabled) 
     
    1 X-10 Device  Turn an X-10 device, either on or off at begin/end times. (will 
    have a start and end time to program) (time driven) 
    NOTE: SH10A siren cannot be used. 
     
    2 Latch Key Report  Send a special pager report (7110000) indicating system not 
    yet disarmed. (will have a start/end time to send the report) 
    (window driven), (reports only to pager) 
    NOTE: Option *49 must be programmed to be 6 or higher. 
      Make sure unit is armed prior to start of window time. 
      In addition a secondary phone number must be 
    programmed in Option *42. 
     
    3 Automatic Stay Arming  Will arm the system automatically, and bypass any open 
    zones, at a given time. It will send a report to the pager and 
    central station, indicating system has been auto armed stay, 
    plus all bypass reports. (will have only a start time to send the 
    report) (time driven)  
    NOTES: (1) Prior executing auto stay arming, force bypass 
    will be executed - if option *23 was enabled. 
     (2) If pager report is required, Option *49 must be 
    programmed to be 6 or higher. 
     
    4 Reminder Announcements  Will announce the message recorded by your installer. This 
    will be repeated every minute until a key is depressed, or a 
    button type zone does an arm or disarm.
     † 
    NOTE:  Make sure installer programmed the message at the 
    time of installation. 
     
    5 Alarm Clock  Will start a trouble tone (beep) on the speaker, which will 
    continue until a key is depressed. †  
     
    Figure 1. 
     
      
    						
    							– 35 – 
    USER FUNCTIONS 
    Scheduling User Interface 
     
    Day of Week Entries 
     
     
    Entry  
    Day 
    00  Invalid day entry  
    01  Do event on next time match on the next Monday (will remove itself after executing)  
    02  Do event on next time match on the next Tuesday (will remove itself after executing)  
    03  Do event on next time match on the next Wednesday (will remove itself after executing)  
    04  Do event on next time match on the next Thursday (will remove itself after executing)  
    05  Do event on next time match on the next Friday (will remove itself after executing)  
    06  Do event on next time match on the next Saturday (will remove itself after executing)  
    07  Do event on next time match on the next Sunday (will remove itself after executing)  
    08  Do event on next time match every day (will run continuously, remains in schedule after 
    executing) 
     
    09  Do event on next time match every weekday (will run continuously, remains in schedule 
    after executing) 
     
    10  Do event on next time match every day of the weekend (will run continuously, remains in 
    schedule after executing) 
     
    11  Do event on next time match on the next Monday (will run continuously, remains in 
    schedule after executing) 
     
    12  Do event on next time match on the next Tuesday (will run continuously, remains in 
    schedule after executing) 
     
    13  Do event on next time match on the next Wednesday (will run continuously, remains in 
    schedule after executing) 
     
    14  Do event on next time match on the next Thursday (will run continuously, remains in 
    schedule after executing) 
     
    15  Do event on next time match on the next Friday (will run continuously, remains in 
    schedule after executing) 
     
    16  Do event on next time match on the next Saturday (will run continuously, remains in 
    schedule after executing) 
     
    17  Do event on next time match on the next Sunday (will run continuously, remains in 
    schedule after executing) 
     
     
    Figure 2.  
    						
    							– 36 – 
    USER FUNCTIONS 
    Remote Phone Control Feature 
     
    The LYNXR-Series is equipped with a remote interactive phone capability that permits access to the 
    security system from any off-site touch-tone telephone using all user codes. If this feature has been 
    programmed, the system will provide the appropriate voice messages and any system beeping sounds 
    indicating the status of the security system over the phone line. (Refer to Summary of Audible 
    Notification for further information.) The following functions can be performed from any remote touch-
    tone  telephone: 
    • Disarm the system. 
    • Arm the system in STAY or AWAY mode. 
    • Activate or deactivate X-10 devices. 
    • Bypass zones. 
    • Check system status. 
     The remote access session will be aborted if: 
    • A report must be sent. 
    • Any local or wireless key entry (e.g. 5827), except [*], is made.  
    • User Code is not entered within eight (8) seconds of call pickup (during the “system…..system 
    announcement). 
    • No keys are depressed for a period of 15 seconds and while no announcement has been made by the 
    system. Any remote key entry will, however extend this timeout back to 15 seconds. 
     It will not be possible to begin a remote access session if: 
    • A report must be sent 
    • The system is in any Test mode. 
    • During  real time clock setting. 
    • During scheduling setup. 
    • Panel is in shutdown mode (programmed by your installer). 
    • Panel is in Macro learning mode. 
    • Remote phone control feature has not been enabled by your installer. 
     NOTE:  If a remote phone session is not granted by the system, for any of the reasons identified above, a modem 
    tone will be generated before the end of the session. 
    Using Remote Phone Control Feature 
    Dial the controls’s phone number. If no answering machine is present, the control will pick up between 
    1 and 14 rings, depending on the number programmed by your installer and will periodically announce 
    “SYSTEM”. During a remote phone control session “PC” will be displayed on the control. 
    Enter: 
                           (within eight seconds) 
      Your user code 
    The system status will be announced. Enter phone control commands as described on the next page: 
     
    If an answering machine is on the premises, you need to dial the premises and hang up on the first 
    ring. Wait at least five (5) seconds (but no more than 22 seconds) and dial the premises phone number 
    again. The control will pick up and periodically announce “SYSTEM”.  
    NOTE 
    (1)  All voice announcements on the phone line will 
    also be announced on the local speaker, unless 
    the system has been placed in the mute mode.
    (2)  Entry/Exit beeps will be terminated if you 
    enter the remote phone access mode.  
    						
    							– 37 – 
    USER FUNCTIONS 
    Remote Phone Control Feature 
     
    Enter:                        (within eight seconds) 
      Your user code 
    Upon entering remote phone control mode the Lynx will announce “System, enter code”. 
    Remote Phone Control Commands 
     
    To remotely disarm system: 
                           + [1] 
      Your user code 
    To remotely arm in AWAY mode:                        + [2] 
      Your user code 
    To remotely arm in STAY mode:                        + [3] 
      Your user code 
    To remotely arm in AWAY or STAY mode with no delay:                        + [2] or [3] + [0] 
     Your user code 
    To remotely activate X-10 devices 1-6: [#] + [4] + device no. 
    To remotely activate X-10 devices 7 & 8:                        + [#] + [4] + device no. 
      Your user code 
    To remotely deactivate X-10 devices 1-6: [#] + [7] + device no. 
    To remotely deactivate X-10 devices 7 & 8:                        +  [#] + [7] + device no. 
      Your user code 
    To remotely Bypass zones:                        + [6] + zone no. 
      Your user code 
    To remotely activate Forced Bypass:                        + [6] + [#] 
      Your user code 
    To remotely check system status: [✻] 
    To end remote phone session: 
    Hang Up  or                        + [9]  
      Your user code
      
     
    NOTES:  (1)  Check with your installer to see if the Forced Bypass mode has been enabled. 
      (2)  When bypassing zones, make sure a confirmation beep sounds for each zone that has been bypassed.  
    						
    							– 38 – 
    USER FUNCTIONS 
    Speaker Phone Feature 
     
    If this feature has been programmed the LYNXR-EN is capable of operating as a speaker phone. 
    During speaker phone operation the system will provide the following functions: 
    • All function/event processing will continue to operate, but there will be no announcements. 
    • The ARMED (red) and READY (green) LEDs will alternately blink. 
    • “PH” will be displayed. 
    NOTE:  The system will enter the Speaker phone mode even if an alarm or trouble is stored in the system memory. 
    Although “PH” may not appear, the LEDs will alternately blink indicating you are currently in the 
    Speaker Phone mode. 
     
    !
    !! ! 
        
    Do not use the speaker phone as the only telephone in your home since in some special cases the 
    speaker phone is not functional. 
    The system will not enter speaker phone mode and LYNXR-EN will not ring if: 
    • The feature has not been programmed. 
    • A report is being sent. 
    • An audible alarm is present. 
    • An announcement is being made or a recorded message is being played back. 
    • A message is being recorded. 
    • If the system is in test or sniffer mode. 
    • AC power is not present 
    The speaker phone will be aborted if: 
    • A report must be sent. 
    • An audible alarm or trouble has ocurred.  
    • AC power is lost. 
    Using the Speaker Phone Feature 
    When the LYNXR-EN is operating in the speaker phone mode the system keypad functions as a 
    telephone keypad and the only security keypad functions that will remain enabled are the panic keys 
    and the speaker volume control. (refer to Volume Adjustment section) You may adjust the volume 
    before entering speaker phone mode or after dialing the desired number. In the speaker phone mode, if 
    a zone is violated and has triggered an entry/exit delay, the system will automatically change the 
    keypad from telephone to security mode. This allows the user to disarm the system or take other 
    appropriate actions in the security mode without interrupting the telephone session. To regain 
    telephone keypad control (i.e.: to enter an account number or menu selection) you will need to 
    reactivate the telephone keypad. 
      
    						
    							– 39 – 
    USER FUNCTIONS 
    Speaker Phone Feature 
     
    LYNXR-EN Speaker Phone Functions 
    To place a call using the Speaker Phone:  
    [#] + AUX and dial the desired phone number. 
    To answer a call using the Speaker Phone: 
    [#] + AUX  
    To flash (switch between two calls using call waiting): 
    AUX  
    To hang up:  
    OFF   
    To activate/deactivate (toggle) ringer:  
    [#] +  VOLUME  +  AUX  
    To return the keypad to telephone mode after disarming the system: 
    [#] + AUX  
    NOTES:  (1)  The speaker phone ringer can only be enabled/disabled when the speaker phone mode is not active. 
    The system will ring once to confirm the ringer is enabled.  Entering 
    [#] +VOLUME +AUX a 
    second time will disable the ringer. No ring will confirm that the ringer is disabled. 
      (2)  The speaker phone ringer will not ring when an alarm, trouble or entry/exit delay are sounding. 
      (3)  The LYNXR-EN speaker phone does not provide a “hold” feature.
     
    NOTE 
    If  you are using pulse (rotary) 
    dialing, make sure that LYNXR-
    EN has finished dialing the last 
    digit you dialed, (listen to pulses) 
    before dialing the next digit.
      
    						
    							– 40 – 
    FIRE ALARM SYSTE
    FIRE ALARM SYSTEFIRE ALARM SYSTE FIRE ALARM SYSTEM 
    M M  M (If Installed)
    (If Installed)(If Installed) (If Installed) 
        
    General Information 
     
    U
    UU U
    L
    LL L 
        
     LYNXR-EN is not intended for UL985 Household Fire applications unless a 24-hour backup battery 
    (P/N LYNXRCHKIT-HC) is installed. 
     
    General  
    Your fire alarm system (if installed) is active 24 hours a day, providing continuous protection. In the 
    event of an emergency, the installed smoke and heat detectors will automatically activate your security 
    system, triggering a loud, intermittent sound from the keypad.  An intermittent sound will also be 
    produced by optional exterior sounders, and interlaced with the voice descriptor, sounding every 15 
    seconds. A “FIRE” message will appear at your keypad and remain on until you silence and clear the 
    alarm display.  
     
    In Case of Fire  
    1.  Should you become aware of a fire emergency before your detectors sense the problem, go to your 
    nearest keypad and press the single panic key (or panic key pair) assigned as FIRE emergency (if 
    programmed by the installer) and hold down for at least 2 seconds. The alarm will sound. 
    2.  Evacuate all occupants from the premises. 
    3.  If flames and/or smoke are present, leave the premises and notify your local Fire Department 
    immediately. 
    4.  If no flames or smoke are apparent, investigate the cause of the alarm. The zone number of the 
    zone(s) in an alarm condition will appear at the keypad. 
     
    Silencing a Fire Alarm 
    1.  Silence the alarm by entering:                         +  OFF key.  
        Your user code
     
      To clear the alarm display, enter:  
                            +  OFF key again. 
        Your user code
     
    2.  If the keypad indicates a trouble condition after the second OFF sequence, check that smoke 
    detectors are not responding to smoke- or heat-producing objects in their vicinity. Should this be 
    the case, eliminate the source of heat or smoke. 
    3.  If this does not remedy the problem, there may still be smoke in the detector.  Clear it by fanning 
    the detector for about 30 seconds. 
    4.  When the problem has been corrected, clear the display by entering:
                             +  OFF key. 