Home > Honeywell > Thermostat > Honeywell Rth2510b1000a Manual

Honeywell Rth2510b1000a Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell Rth2510b1000a Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							RT H 2 510 / RT H 2410
     9 69-2725ES—01
    Save money by setting program schedules
    It’s easy to program your system for maximum energy savings. You can program four time 
    periods each day, with different settings for weekdays and weekends.
    Set to the time you awaken and the temperature you want 
    during the morning, until you leave for the day.
    Set to the time you leave home and the temperature you 
    want while you are away (usually an energy-saving level).
    Set to the time you return home and the temperature you 
    want during the evening, until bedtime.
    Set to the time you go to bed and the temperature you want 
    overnight (usually an energy-saving level).
    WAKE6:00 am
    70 °
    LEAVE8:00 am
    62 °
    RETURN6:00 pm
    70 °
    SLEEP10:00 pm
    62 ° 
    						
    							Operating Manual
    69-2725ES—01 10
    About your new thermostatEnergy saving settings for maximum cost savings
    This thermostat is pre-set to use energy saving program settings. We recommend these 
    settings, since they can reduce your heating/cooling expenses by as much as 33%. (See 
    next page to adjust times and temperatures of each time period.)
    Wake(6:00 am)
    Leave(8:00 am)
    Return(6:00 pm)
    Sleep(10:00 pm)
    Cool (Mon-Fri)Heat (Mon-Fri)Heat (Sat-Sun)Cool (Sat-Sun)
    70 °78 °70 °78 °
    62 °85 °62 °85 °
    70 °78 °70 °78 °
    62 °82 °62 °82 ° 
    						
    							RT H 2 510 / RT H 2410
     11 69-2725ES—01
    MoWakeSet Schedule
    Setam
    756:
    30
    M33600
    Set
    Hold
    Run
    To adjust program schedules (RTH2510)
    1.  Press SET until Set Schedule is displayed.
    2. Press s or t to set your Wake time for the day displayed, then press SET.
    3. Press s or t to set the temperature for this time period, then press SET.
    4. Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each day’s time period.
    5.  Press RUN to save & exit.
    Note: Make sure the thermostat is set to the system you want to program (Heat or Cool). 
    Press SET 3 times, then adjust time.
    Press SET, then set desired temperature. 
    						
    							Operating Manual
    69-2725ES—01 12
    Mo Tu We  Th Fr W akeSet Schedule
    Setam
    756:
    30
    M33601
    Set
    Hold
    Run
    To adjust program schedules (RTH2410)
    1.  Press SET until Set Schedule is displayed.
    2. Press s or t to set your weekday Wake time (Mo-Fr), then press SET.
    3. Press s or t to set the temperature for this time period, then press SET.
    4. Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period.
    5.  Press SET to set weekend time periods (Sa & Su), then press RUN to save & exit.
    Note: Make sure the thermostat is set to the system you want to program (Heat or Cool). 
    Press SET 3 times, then adjust time.
    Press SET, then set desired temperature. 
    						
    							RT H 2 510 / RT H 2410
     13 69-2725ES—01
    About your new thermostat
    Temporary
    Set
    am
    706 :
    30
    M3360 2
    Set
    Hold
    Run
    Setam
    756 :
    30
    M33603
    Set
    Hold
    Run
    Program schedule override (temporary)
    Press s or t to immediately adjust the 
    temperature. This will temporarily override 
    the temperature setting for the current time 
    period.
    “Temporary” will appear on the display.
    The new temperature will be maintained 
    only until the next programmed time period 
    begins (see page 9).
    To cancel the temporary setting at any time, 
    press RUN.
    Press to temporarily adjust temperature.
    Press to cancel temporary setting and resume program schedule.
    Note: Make sure the thermostat is set to the system you want to control (heat or cool). 
    						
    							Operating Manual
    69-2725ES—01 14
    About your new thermostat
    Hold
    Setam
    706
    :
    30
    M33604
    Set
    Hold
    Run
    Setam
    756 :
    30
    M33603
    Set
    Hold
    Run
    Program schedule override (permanent)
    Note: Make sure the thermostat is set to the system you want to control (heat or cool).
    Press to permanently adjust temperature.Press HOLD to permanently adjust 
    the temperature. This will override the 
    temperature settings for all time periods.
    The “Hold” feature turns off the program 
    schedule and allows you to adjust the 
    thermostat manually, as needed.
    Whatever temperature you set will be 
    maintained 24 hours a day, until you 
    manually change it, or press RUN to cancel 
    “Hold” and resume the program schedule.
    Press to cancel “Hold” setting and resume program schedule. 
    						
    							RT H 2 510 / RT H 2410
     15 69-2725ES—01
    About your new thermostatBuilt-in compressor protection
    This feature helps prevent damage to the com-
    pressor in your air conditioning or heat pump 
    system.
    Damage	can	occur	 if	the	 compressor	 is	restarted	
    too soon after shutdown. This feature forces the 
    compressor to wait 5 minutes before restarting.
    During	 the	wait	 time,	 the	display	 will	flash	 the	
    message Cool	On (or Heat	 On if you have 
    a heat pump). When the safe wait time has 
    elapsed, the message stops flashing and the 
    compressor turns on.
    Message flashes until safe restart time has elapsed.
    We
    Wake
    am
    Cool
    75
     On 
    6:
    30
    M3271 1 
    						
    							Operating Manual
    69-2725ES—01 16
    About your new thermostat
    Early Start: This feature allows the heating or 
    cooling to turn on before the program start 
    time, so the temperature is reached at the time 
    you set. For example: Set the Wake time to 6 
    am, and the temperature to 70°. The heat will 
    come on before 6 am, so the temperature is 
    70° by the time you wake at 6. The next time 
    period is displayed when the system is acti-
    vated before a scheduled time period.
    Early Start
    We
    Wake
    am
    Cool
    75
     On 
    6:
    30
    M32712 
    						
    							RT H 2 510 / RT H 2410
     17 69-2725ES—01
    Change Filter
    If the filter reminder is turned on during 
    installation, the words Change Filter will flash 
    on the screen when the filter needs to be 
    replaced.
    After you replace the air filter, press and hold 
    the RUN button for 3 seconds to reset the alert.
    Setam
    756:
    30
    M33632
    Set
    Hold
    RunC hange Filter – Press & Hold Run to Reset 
    						
    							Operating Manual
    69-2725ES—01 18
    About your new thermostatBattery replacement
    Install two fresh AAA batteries when 
    Lo Batt flashes on the screen. Lo Batt 
    appears for 60 days before the batter-
    ies are depleted.
    Replace batteries once a year, or when 
    you will be away for more than a month.
    Most settings are stored in non-volatile 
    (permanent)	memory.	Only	 the	clock	
    and the day must be set after you 
    replace the batteries.
    Pull at bottom to remove thermostat from wallplate.
    Turn thermostat over, insert fresh AAA alkaline batteries, then reinstall thermostat.
    Set	 the	System	 switch	to	Off	 before	 removing	 the	batteries. 	Otherwise,	 the	heating/cooling	 system	could	remain activated even when batteries are removed.
    RTHXXXX
    M32707
    W/
    Aux Not
    Used
    M33592Heat  Off  CoolAuto  OnFanHeat Off  Cool Auto OnFanHeat  Off  CoolAuto  OnFanHeat Off  Cool Auto OnFan
    Set
    Hold
    Run 
    						
    All Honeywell manuals Comments (0)