HP R120003 User Guide
Have a look at the manual HP R120003 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1114 HP manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

Crowded data centers and racks filled to capacity with storage devices, monitors, servers communications devices, and other equipment are driving the need for uninterruptible power with increased power density and power efficiency. The HP 3 Phase Uninterruptible Power Systems provide just that. These rack-mountable Uninterruptible Power Systems provide up to 12,000 watts (W) of power in a 6-U rack form factor. This equates to 2 KW per U space, which leads the industry in power density. The UPS R8000/3 and the R12000/3 use digital signal processing and a new On-line On Demand hybrid technology to answer the demands for increased power density and power efficiency. On-line On Demand combines the efficiency of a line interactive UPS, up to 97%, with the stability of a double conversion on-line UPS when power fluctuates beyond acceptable limits. Hot swappable batteries and electronics modules and an automatic bypass reduce MTTR (mean time to repair) – down time in the event service is needed. UPS R8000/3 and R12000/3 front view UPS R8000/3 and R12000/3 front viewUPS R8000/3 and R12000/3 front view UPS R8000/3 and R12000/3 front view UPS R8000/3 and R12000/3 rear view UPS R8000/3 and R12000/3 rear viewUPS R8000/3 and R12000/3 rear view UPS R8000/3 and R12000/3 rear view 1. Battery compartment (behind bezel) 1. Communications terminal block 2. Menu navigation buttons 2. Output circuit breaker 3. Status and alarm LED display 3. Input circuit breaker 4. Electronics module compartment (behind bezel) 4. Battery circuit breaker 5. Input/output location R8000/3, input location R12000/3 1 6. ERM connector 7. Option card slots 8. Output connector R12000/3 9. Ground bonding screw 10. DB9 Service port 11. REPO port Models ModelsModels Models HP R8000/3 HP R8000/3HP R8000/3 HP R8000/3 HP R8000/3 Uninterruptible Power System 6U NA AF431A HP R8000/3 Uninterruptible Power System 6U INTL AF432A HP R12000/3 HP R12000/3HP R12000/3 HP R12000/3 HP R12000/3 Uninterruptible Power System 6U NA AF429A HP R12000/3, Uninterruptible Power System 6U INTL AF430A QuickSpecs HP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible PowerHP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible Power Systems SystemsSystems Systems Overview DA - 12857 Worldwide — Version 1 — November 12, 2007 Page 1

Key Features Key FeaturesKey Features Key Features Unity Rated, volt amperage out equals wattage out Highest wattage per U space. Up to 12000 VA/12KW in only 6U! Industry leading efficiency with On-line On Demand hybrid technology Attached line cords for easier and faster connection to your facility power Hot-swappable battery and electronics modules provide ease of maintenance and faster time to repair (MTTR) Industry leading efficiency with On-line On Demand hybrid technology Attached line cords for easier and faster connection to your facility power Extra long battery life with Enhanced Battery Management (EBM) Extended battery run time with optional Extended Runtime Modules (ERMs) Easy configuration through enhanced front panel display or included management software Backed by a limited three-year warranty, HPs pre-failure warranty and a load protection guarantee in North America QuickSpecs HP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible PowerHP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible Power Systems SystemsSystems Systems Overview DA - 12857 Worldwide — Version 1 — November 12, 2007 Page 2

Superior Battery Superior BatterySuperior Battery Superior Battery Management ManagementManagement Management HP UPS HP 3 PHASE UPS incorporates Enhanced Battery Management: an exclusive, patented technology that doubles battery service life, optimizes battery recharge time, and provides advance notice of pending battery failure. With Enhanced Battery Management, you have a lower total cost of ownership and receive the best in the industry protection for your critical equipment. Ease of serviceability Ease of serviceabilityEase of serviceability Ease of serviceability through hot-swappable through hot-swappablethrough hot-swappable through hot-swappable batteries and electronics batteries and electronicsbatteries and electronics batteries and electronics modules. modules.modules. modules. The HP 3 PHASE UPSs have a modular design architecture, consisting of separate, hot swappable battery and electronics modules. Further, a built-in intelligent automatic bypass feature ensures continuous power to your connected load even while the modules are being replaced. Ease of maintenance and serviceability Faster time to repair (MTTR) Automatic and manual bypass Increased flexibility through modular design Increase battery back-up Increase battery back-upIncrease battery back-up Increase battery back-up time with up to four time with up to fourtime with up to four time with up to four Extended Runtime Extended RuntimeExtended Runtime Extended Runtime Modules ModulesModules Modules HP 3 PHASE UPS supports a maximum of four Extended Runtime Modules (ERM), to further increase your battery back-up time, should you have a sudden brief power outage. Each ERM is 3U high and can be automatically detected and configure when attached to the UPS. For more information on battery back up times, please refer to the Back-up Times Chart. Multiple management Multiple managementMultiple management Multiple management options increase flexibility options increase flexibilityoptions increase flexibility options increase flexibility The HP 3 Phase UPS systems can bee fully configured and monitored from the front management LCD. For remote management HP Power Manager software is included at no charge and the optional UPS Management Module provides additional features such as out of band communications with up to 5 servers and UPS clustering for redundancy. Remote Emergency Power Remote Emergency PowerRemote Emergency Power Remote Emergency Power Off Feature Off FeatureOff Feature Off Feature The HP 3 Phase UPS includes an isolated REPO (Remote Emergency Power Off) port. The REPO feature allows the power to the UPS outlets to be switched off from a remote location. For more information, refer the HP 3 Phase UPS users manual. UPS Management Module UPS Management ModuleUPS Management Module UPS Management Module The optional HP UPS Management Module enables you to monitor and manage power environments through comprehensive control of HP UPSs. The HP UPS Management Module can support either a single UPS configuration or provides additional power protection with support for dual redundant UPS configuration for no-single-point-of-failure. The additional serial ports will provide greater power management control and flexible monitoring. The management module can be configured to send alert traps to HP Systems Insight Manager and other SNMP management programs or used as a standalone management system. This flexibility enables you to monitor and manage UPSs through the network. To facilitate day-to-day maintenance tasks, the embedded management software provides detailed system logs. The HP UPS Management Module provides remote management of a UPS by connecting the UPS directly to the network. Configuration & Management of the UPS from anywhere and at anytime via a standard web browser. NOTE: NOTE: NOTE: NOTE: For more information on the UPS Management Module please see http://h18004.www1.hp.com/products/servers/proliantstorage/powerprotection/ software/module/ups/index.html QuickSpecs HP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible PowerHP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible Power Systems SystemsSystems Systems Product Highlights DA - 12857 Worldwide — Version 1 — November 12, 2007 Page 3

Warranty WarrantyWarranty Warranty Standard three year warranty with first year including parts and labor. HP UPSs are backed by a standard three year limited warranty; 3 year parts, 1 year Labor, 1 year onsite. Optional UPS HP Care Pack and packaged services are also available for purchase. You can choose the precise level of support based on your needs, from basic to business critical. Pre-Failure Battery Warning and its associated Warranty. The Pre-Failure Battery Warning is proactively detected and notified by a LED indicator light, showing that the battery needs to be replaced. This notice is given 30 days prior to the battery failure. This indicator provides ample time to order a spare battery (1-800-OK-COMPAQ). Avoid storing battery spares as a back up because of short shelf life of the battery. The battery warranty coverage is 3 years for parts. The warranty for the first year of ownership includes parts and labor. Warranty, standard on all HP Uninterruptible Power System (UPS) units, extends the advantage of a HP three-year limited warranty by applying it to the battery before it actually fails. Specifically, the Pre-Failure Battery Warranty ensures that when customers receive the notification from their HP UPS that the battery may fail, the battery is replaced free of charge under the warranty. HP maintains the highest standards in the industry, as evidenced by the HP Pre-Failure Battery Warranty. In addition, HP UPSs are covered by a $250,000 equipment protection guarantee. Should your connected equipment get damaged due to a UPS failure, then your damaged equipment is covered to up to $250,000. NOTE: NOTE: NOTE: NOTE: The $250,000 Equipment Protection Guarantee is offered only in North America. HP Care Pack Services HP Care Pack ServicesHP Care Pack Services HP Care Pack Services HP Care Pack Services include HP branded hardware options qualified for the server, purchased at the same time or afterwards, internal to the enclosure, as well as 22 and smaller external monitors and rack mounted UPS options. HP Uninterruptible Power Systems will be covered at the same service level and coverage period as the server. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. NOTE: NOTE: NOTE: NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or resellers or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack NOTE: NOTE: NOTE: NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps NOTE: NOTE: NOTE: NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html NOTE: NOTE: NOTE: NOTE: The information contained herein is subject to change without notice and is provided as is without warranty of any kind. NOTE: NOTE: NOTE: NOTE: The warranties for HP products and services are set forth in the express limited warranty statements accompanying such products and services. QuickSpecs HP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible PowerHP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible Power Systems SystemsSystems Systems Service and Support, HP Care Pack, and Warranty Information DA - 12857 Worldwide — Version 1 — November 12, 2007 Page 4

Extended Runtime Module Extended Runtime ModuleExtended Runtime Module Extended Runtime Module Extended Runtime Module (WW) NOTE: NOTE: NOTE: NOTE: HP 3 PHASE UPS supports a maximum of four Extended Runtime Modules (ERM), to further increase your battery back-up time. Each ERM is 3U high and can be automatically detected and configure when attached to the UPS. For more information on battery back up times, please refer to the Back-up Times Chart. AF434A UPS Management Module UPS Management ModuleUPS Management Module UPS Management Module HP UPS Management Module NOTE: NOTE: NOTE: NOTE: For more information on the UPS Management Module please see http://h18004.www1.hp.com/products/servers/proliantstorage/powerprotection/ software/module/ups/index.html AF401A Serial Adapter Serial AdapterSerial Adapter Serial Adapter HP Serial Adapter RJ45-DB89 DCE Female 5pk NOTE: NOTE: NOTE: NOTE: The serial adapters allow direct (serial) connections to up to 5 servers with the UPS Management Module for out of band communications in the event of a power failure. AF402A Rackmount Power Rackmount PowerRackmount Power Rackmount Power Distribution Units (PDUs) Distribution Units (PDUs)Distribution Units (PDUs) Distribution Units (PDUs) and PDU options and PDU optionsand PDU options and PDU options North America/Japan North America/JapanNorth America/Japan North America/Japan 8.6 kVA 3F Modular PDU (core only) with L15-30 inlet cord and 6 x IEC C19 outlets AF512A 8.6 kVA 3F Monitored PDU model S1324 with one L15-30 inlet cord, and 36 IEC C- 13 plus 3 IEC C19 outlets AF504A 17.3 kVA 3F Monitored PDU model S2324 with two L15-30 inlet cords, and 72 IEC C-13 plus 6 IEC C19 outlets AF503A NOTE: NOTE: NOTE: NOTE: The HP R8000/3 UPS can support one AF512A or AF504A. The HP R12000/3 UPS can support two AF512A or AF504A or one AF503A. International InternationalInternational International 11 kVA 3F Modular PDU (core only) with IEC309 416P6 (16A) inlet cord and 6 x IEC C19 outlets AF513A 11 kVA 3F Monitored PDU model S1316 with one IEC309 416P6 (16A) inlet cord and 36 IEC C-13 plus 3 IEC C19 outlets AF508A 22.1 kVA 3F Monitored PDU model S2316 with two IEC309 416P6 (16A) inlet cords and 72 IEC C-13 plus 6 IEC C19 outlets AF507A NOTE: NOTE: NOTE: NOTE: The HP R8000/3 UPS can support one AF513A or AF508A. The HP R12000/3 UPS can support two AF513A or AF508A or one AF507A. PDU Management Module NOTE: NOTE: NOTE: NOTE: For more information on the PDU Management Module please see http://h18004.www1.hp.com/products/servers/proliantstorage/ powerprotection/pdu.html AF400A PDU Extension Bars PDU Extension BarsPDU Extension Bars PDU Extension Bars (PDU options) HP C-13 PDU Extension Bar Kit, pair NOTE: NOTE: NOTE: NOTE: Each extension bar has a C-20 input cord and 7 x C-13 receptacles. AF500A HP Fixed Cord Extension Bar Kit, pair NOTE: NOTE: NOTE: NOTE: Each extension bar has a C-20 input cord and 7 attached 13 inch C-13 power cords for use with 1U servers 351655-B21 NOTE: NOTE: NOTE: NOTE: Extension bars may be used with any HP PDU that has C-19 outlets QuickSpecs HP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible PowerHP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible Power Systems SystemsSystems Systems Related Options DA - 12857 Worldwide — Version 1 — November 12, 2007 Page 5

HP Power Cables HP Power CablesHP Power Cables HP Power Cables 10A, IEC320 C-14 to IEC320 C-13 Cables, 4.5ft (1.37m), 15 pack 142257-007 10A, IEC320 C-14 to IEC320 C-13 Cables, 4.5ft (1.37m), single 15 pack 142257-006 10A, IEC320 C-14 to IEC320 C-13 Cables, 1.6ft (0.5m), single pack 142257-B28 16A, IEC320 C-19 to IEC320 C-20 Cables, 8ft (2.5m), single pack 295633-B22 16A, IEC320 C-19 to IEC320 C-20 Cables, 6.5ft (2m), single pack AF574A 16A, IEC320 C-19 to IEC320 C-20 Cables, 4ft (1.2m), single pack AF575A 16A, IEC320 C-19 to IEC320 C-20 Cables, 3ft (1m), single pack E7798A NOTE: NOTE: NOTE: NOTE: For more information on HP power cords please go to: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/ power-protection/power-cord-option-kits.pdf Service and Support Service and SupportService and Support Service and Support Offerings OfferingsOfferings Offerings (HP Care Pack Services) Hardware Installation (Electronic) U4696E QuickSpecs HP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible PowerHP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible Power Systems SystemsSystems Systems Related Options DA - 12857 Worldwide — Version 1 — November 12, 2007 Page 6

R8000/3 NA R8000/3 NAR8000/3 NA R8000/3 NA R8000/3 INTL R8000/3 INTLR8000/3 INTL R8000/3 INTL R12000/3 NA R12000/3 NAR12000/3 NA R12000/3 NA R12000/3 INTL R12000/3 INTLR12000/3 INTL R12000/3 INTL Electrical Output Electrical OutputElectrical Output Electrical Output Power Output Power OutputPower Output Power Output 8kVA/8KW @ 208v 3F Delta 8kVA/8KW @ 400v 3F Wye 12kVA/12KW @ 208v 3F Delta 12kVA/12KW @ 400v 3F Wye Nominal output frequency Nominal output frequencyNominal output frequency Nominal output frequency 50-60 Hz auto-detection (Normal mode) 50 or 60 Hz (Battery mode) Output Frequency Output FrequencyOutput Frequency Output Frequency Variation VariationVariation Variation Synchronized (Normal mode) ±0.1 when not synchronized with source (Battery mode) Output overload Output overloadOutput overload Output overload 100–110%: load transfers to Bypass mode after 10 minutes 110–125%: load transfers to Bypass mode after 1 minute 125–150%: load transfers to Bypass mode after 5 seconds >150%: load transfers to Bypass mode after 300 ms Voltage wave form Voltage wave formVoltage wave form Voltage wave form Sine wave; 2% THD with typical PFC load Surge suppression Surge suppressionSurge suppression Surge suppression High-energy 6500 A peak Noise filtering Noise filteringNoise filtering Noise filtering MOVs and line filter Output Connections Output ConnectionsOutput Connections Output Connections One NEMA L15- 30R One IEC309 516C6 (16A) Two NEMA L15- 30R Two IEC309 516C6 (16A) Electrical Input Electrical InputElectrical Input Electrical Input Voltage Range Voltage RangeVoltage Range Voltage Range 200-240 v 3F Wye 380-415v 3F Wye 208v 3F Wye 380-415v 3F Wye Nominal voltage Nominal voltageNominal voltage Nominal voltage 208v 3F Wye 400v 3F Wye 208v 3F Wye 400v 3F Wye Nominal frequency Nominal frequencyNominal frequency Nominal frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Frequency range Frequency rangeFrequency range Frequency range 45-65 Hz 45-65 Hz 45-65 Hz 45-65 Hz Rated input current Rated input currentRated input current Rated input current 18 amps 34.4 amps Maximum input current at Maximum input current atMaximum input current at Maximum input current at nominal voltage nominal voltagenominal voltage nominal voltage 22.4 amps 43A Efficiency EfficiencyEfficiency Efficiency 97% @ 40-100% load 97% @ 40-100% load 97% @ 40-100% load 97% @ 40-100% load Input connector Input connectorInput connector Input connector NEMA L15-30 IEC309 516P6 (16A) IEC309 560P9 IEC309 563P6 (63A) Operating Temperature Operating TemperatureOperating Temperature Operating Temperature Operating Temperature Operating TemperatureOperating Temperature Operating Temperature 50°F to 104°F (10°C to 40°C) Optimal battery Optimal batteryOptimal battery Optimal battery performance performanceperformance performance 41°F to 77°F (5°C to 25°C) Non-operating Non-operatingNon-operating Non-operating Temperature TemperatureTemperature Temperature -13°F to 131°F (-25°C to 55°C) Relative Humidity Relative HumidityRelative Humidity Relative Humidity Operating OperatingOperating Operating 5% to 95% non-condensing Operating Altitude Operating AltitudeOperating Altitude Operating Altitude Up to 3300 ft (1,000 meters) above sea level; up to 6600 ft (2,000 meters) with 1% derating per +330 ft (100 meters) Transit Altitude Transit AltitudeTransit Altitude Transit Altitude Up to 49,212 ft (15,000 meters) above sea level Heat Dissipation Heat DissipationHeat Dissipation Heat Dissipation 1266 BTU/hr maximum at 100% rated load (High Efficiency mode) Audible Noise Audible NoiseAudible Noise Audible Noise Less than 50 dBA at 1 meter (Normal mode) Less than 55 dBA at 1 meter (Battery mode) Leakage Current Leakage CurrentLeakage Current Leakage Current < 3.5 mA Surge suppression Surge suppressionSurge suppression Surge suppression ANSI C62.41 Category B3 QuickSpecs HP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible PowerHP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible Power Systems SystemsSystems Systems Technical Specifications DA - 12857 Worldwide — Version 1 — November 12, 2007 Page 7

Safety Conformance Safety ConformanceSafety Conformance Safety Conformance UL 1778 4th edition; CSA C22.2, No. 107.3 EN and IEC 62040-1-1 UL 1778 4th edition; CSA C22.2, No. 107.3 EN and IEC 62040-1-1 EMC EMCEMC EMC (Class A) FCC Part 15 EN 62040-2 FCC Part EN 62040-2 Unit Dimensions Unit DimensionsUnit Dimensions Unit Dimensions (WxDxH) 14.4 x 26 x 10.3 in (441 x 660 x 261 mm) 6U Shipping Dimensions Shipping DimensionsShipping Dimensions Shipping Dimensions (WxDxH) 25 x 38 x 46 in (635 x 965 x 1169 mm) Unit Weight Unit WeightUnit Weight Unit Weight Without batteries Without batteriesWithout batteries Without batteries 135 lb (61 kg) With batteries installed With batteries installedWith batteries installed With batteries installed 307 lb (140 kg) Shipping Weight Shipping WeightShipping Weight Shipping Weight 400 lbs (182 kg) Extended Runtime Module Extended Runtime ModuleExtended Runtime Module Extended Runtime Module (ERM) Unit Dimensions Unit Dimensions Unit Dimensions Unit Dimensions (WxDxH) 17.2 x 26 x 5.2 in (438 x 660 x 131 mm) 3U Shipping Dimensions Shipping DimensionsShipping Dimensions Shipping Dimensions (WxDxH) 47.25 x 31.5 x 37 in (1207 x 800 x 940 mm) Unit Weight Unit WeightUnit Weight Unit Weight 170 lbs (77 kg) Shipping Weight Shipping WeightShipping Weight Shipping Weight 185 lb (84 kg) Estimated Backup Times Chart (Minutes) R8000/3 Estimated Backup Times Chart (Minutes) R8000/3Estimated Backup Times Chart (Minutes) R8000/3 Estimated Backup Times Chart (Minutes) R8000/3 Load % Load %Load % Load % With Internal Battery With Internal BatteryWith Internal Battery With Internal Battery With 1 ERM With 1 ERMWith 1 ERM With 1 ERM With 2 ERMs With 2 ERMsWith 2 ERMs With 2 ERMs With 3 ERMs With 3 ERMsWith 3 ERMs With 3 ERMs With 4 ERMs With 4 ERMsWith 4 ERMs With 4 ERMs 20% 55 118 183 253 329 50% 23 46 69 94 120 80% 12 27 41 55 70 100% 9 21 32 43 54 Estimated Backup Times Chart (Minutes) R12000/3 Estimated Backup Times Chart (Minutes) R12000/3Estimated Backup Times Chart (Minutes) R12000/3 Estimated Backup Times Chart (Minutes) R12000/3 20% 37 78 119 163 211 50% 13 30 44 59 76 80% 6 17 26 34 44 100% 5 12 20 27 34 NOTE: NOTE: NOTE: NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions. Environment-friendly Environment-friendlyEnvironment-friendly Environment-friendly Products and Approach Products and ApproachProducts and Approach Products and Approach End-of-life Management End-of-life ManagementEnd-of-life Management End-of-life Management and Recycling and Recyclingand Recycling and Recycling Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to http://www.hp.com/go/green . To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green . These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. QuickSpecs HP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible PowerHP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible Power Systems SystemsSystems Systems Technical Specifications DA - 12857 Worldwide — Version 1 — November 12, 2007 Page 8

© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. QuickSpecs HP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible PowerHP Rackmountable 3 Phase Uninterruptible Power HP Rackmountable 3 Phase Uninterruptible Power Systems SystemsSystems Systems Technical Specifications DA - 12857 Worldwide — Version 1 — November 12, 2007 Page 9